POLYCLONAL AND MONOCLONAL-ANTIBODIES AGAINST HUMAN TISSUE INHIBITOR OF METALLOPROTEINASES (TIMP) AND THE DESIGN OF AN ENZYME-LINKED-IMMUNOSORBENT-ASSAY TO MEASURE TIMP

被引:54
作者
CLARK, IM
POWELL, LK
WRIGHT, JK
CAWSTON, TE
机构
[1] Rheumatology Research Unit, Addenbrooke's Hospital, Cambridge, CB2 2QQ, Hills Road
来源
MATRIX | 1991年 / 11卷 / 02期
关键词
MONOCLONAL ANTIBODY; POLYCLONAL ANTIBODY; SANDWICH ENZYME IMMUNOASSAY; TISSUE INHIBITOR OF METALLOPROTEINASES (TIMP);
D O I
10.1016/S0934-8832(11)80211-8
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Both polyclonal and monoclonal antibodies have been raised against purified human fibroblast tissue inhibitor of metalloproteinases (TIMP) and characterised. Combinations of antibodies were tested for their suitability in a double antibody sandwich ELISA to measure TIMP. Two combinations were applicable to the immunoassay: (i) a monoclonal capture antibody with a polyclonal detecting antibody; (ii) two monoclonal antibodies. The assay range was (i) 2-50 ng/ml and (ii) 5-50 ng/ml of human TIMP. The levels of TIMP in several human body fluids were measured using assay (ii), and values in ng/ml with standard deviations (n-1) obtained as follows: serum, 229 +/- 62; plasma, 109 +/- 35; amniotic fluid, 724 +/- 62; cerebrospinal fluid, 144 +/- 156; saliva, 209 +/- 103.
引用
收藏
页码:76 / 85
页数:10
相关论文
共 31 条