MODEL OF HEAT SIMULATOR FOR DATA CENTERS

被引:0
作者
Novotny, Jan [1 ]
Nozicka, Jiri [1 ]
机构
[1] Czech Tech Univ, Fac Mech Engn, Dept Fluid Dynam & Thermodynam, Tech 4, Prague 16607 6, Czech Republic
关键词
data center; cooling; heat simulator; PIV; measurement;
D O I
10.14311/AP.2016.56.0301
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The aim of this paper is to present a design and a development of a heat simulator, which will be used for a flow research in data centers. The designed heat simulator is based on an ideological basis of four-processor 1U Supermicro server. The designed heat simulator enables to control the flow and heat output within the range of 10-100 %. The paper covers also the results of testing measurements of mass flow rates and heat flow rates in the simulator. The flow field at the outlet of the server was measured by the stereo PIV method. The heat flow rate was determined, based on measuring the temperature field at the inlet and outlet of the simulator and known mass flow rate.
引用
收藏
页码:301 / 305
页数:5
相关论文
共 50 条
  • [31] Performance investigation of a biomimetic latent heat thermal energy storage device for waste heat recovery in data centers
    Huang, Yongping
    Deng, Zilong
    Chen, Yongping
    Zhang, Chengbin
    APPLIED ENERGY, 2023, 335
  • [32] Servers and data centers energy performance metrics
    Beitelmal, A. H.
    Fabris, D.
    ENERGY AND BUILDINGS, 2014, 80 : 562 - 569
  • [33] An economic analysis of waste heat recovery and utilization in data centers considering environmental benefits
    Zhang, Caiqing
    Luo, Hongxia
    Wang, Zixuan
    SUSTAINABLE PRODUCTION AND CONSUMPTION, 2022, 31 : 127 - 138
  • [34] Energy and Exergy Analysis of Modular Data Centers
    Khalid, Rehan
    Wemhoff, Aaron P.
    Joshi, Yogendra
    IEEE TRANSACTIONS ON COMPONENTS PACKAGING AND MANUFACTURING TECHNOLOGY, 2017, 7 (09): : 1440 - 1452
  • [35] Enhancing Cooling Efficiency in Data Centers: An Evaluation of Heat Pipe Design in Air Ducts
    Piarah, Wahyu H.
    Yamani, Muhammad R.
    Djafar, Zulkifli
    Gunadin, Indar C.
    Muslimin, Zaenab
    Arminah, Bidayatul
    Setyawan, Iwan
    Djafar, Zuryati
    INTERNATIONAL JOURNAL OF HEAT AND TECHNOLOGY, 2024, 42 (01) : 263 - 269
  • [36] Integrated power and cooling systems for data centers
    Herold, KE
    Radermacher, R
    ITHERM 2002: EIGHTH INTERSOCIETY CONFERENCE ON THERMAL AND THERMOMECHANICAL PHENOMENA IN ELECTRONIC SYSTEMS, PROCEEDINGS, 2002, : 808 - 811
  • [37] Analytical model of quality of service scheduling for optical aggregation in data centers
    Walter Cerroni
    Carla Raffaelli
    Photonic Network Communications, 2014, 28 : 264 - 275
  • [38] Hybrid surrogate model for online temperature and pressure predictions in data centers
    Asgari, Sahar
    Moazamigoodarzi, Hosein
    Tsai, Peiying Jennifer
    Pal, Souvik
    Zheng, Rong
    Badawy, Ghada
    Puri, Ishwar K.
    FUTURE GENERATION COMPUTER SYSTEMS-THE INTERNATIONAL JOURNAL OF ESCIENCE, 2021, 114 : 531 - 547
  • [39] Analytical model of quality of service scheduling for optical aggregation in data centers
    Cerroni, Walter
    Raffaelli, Carla
    PHOTONIC NETWORK COMMUNICATIONS, 2014, 28 (03) : 264 - 275
  • [40] ENERGY LOSS MODEL FOR TIER 2 AND TIER 3 DATA CENTERS
    Wiboonrat, Montri
    SURANAREE JOURNAL OF SCIENCE AND TECHNOLOGY, 2022, 29 (01):