IMPROVEMENT IN FLOW PROPERTIES AND PH STABILITY OF COMPRESSED, CONTINUOUS POLYMER BEDS FOR HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY

被引:55
作者
HJERTEN, S [1 ]
MOHAMMAD, J [1 ]
NAKAZATO, K [1 ]
机构
[1] KIATASO UNIV,SCH HYG SCI,SAGAMIHARA,KANAGAWA 228,JAPAN
来源
JOURNAL OF CHROMATOGRAPHY | 1993年 / 646卷 / 01期
关键词
D O I
10.1016/S0021-9673(99)87013-7
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Continuous polymer beds can be regarded as rods with channels through which the effluent can pass. The original beds had limited pH stability and did not permit especially high flow-rates. These disadvantages were overcome by synthesizing the beds from piperazine diacrylamide (PDA) and methacrylamide (MA) instead of N,N'-methylenebisacrylamide. For high flow-rates, the amounts of PDA and MA and the ratio between them are critical, as is the concentration of ammonium sulphate. The method of synthesis is simple and cost effective. No organic solvents are used. The beds can be prepared either directly in the chromatographic tube or in a beaker in the form of large clusters of small gel particles and then transferred into the tube. The preparation of the beds is described in detail. For a cation exchanger the resolution of model proteins was roughly independent of the bed height (down to 3.5 mm). The resolution was not affected by the flow-rate or even increased when the flow-rate was increased when using a reversed-phase column.
引用
收藏
页码:121 / 128
页数:8
相关论文
共 18 条
[1]   KINETICS OF UNFOLDING OF PROTEINS ON HYDROPHOBIC SURFACES IN REVERSED-PHASE LIQUID-CHROMATOGRAPHY [J].
BENEDEK, K ;
DONG, S ;
KARGER, BL .
JOURNAL OF CHROMATOGRAPHY, 1984, 317 (DEC) :227-243
[2]   HIGH-PERFORMANCE CHROMATOFOCUSING OF PROTEINS ON AGAROSE COLUMNS .2. DEFORMED NON-POROUS 12-15-MU-M BEADS [J].
HJERTEN, S ;
LI, JP ;
LIAO, JL .
JOURNAL OF CHROMATOGRAPHY, 1989, 475 :177-185
[3]   THE DESIGN OF AGAROSE BEDS FOR HIGH-PERFORMANCE HYDROPHOBIC-INTERACTION CHROMATOGRAPHY AND ION-EXCHANGE CHROMATOGRAPHY WHICH SHOW INCREASING RESOLUTION WITH INCREASING FLOW-RATE [J].
HJERTEN, S ;
YAO, KQ ;
LIAO, JL .
MAKROMOLEKULARE CHEMIE-MACROMOLECULAR SYMPOSIA, 1988, 17 :349-357
[4]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY OF PROTEINS ON COMPRESSED, NON-POROUS AGAROSE BEADS .1. HYDROPHOBIC-INTERACTION CHROMATOGRAPHY [J].
HJERTEN, S ;
LIAO, JL .
JOURNAL OF CHROMATOGRAPHY, 1988, 457 :165-174
[5]   CONTINUOUS BEDS - HIGH-RESOLVING, COST-EFFECTIVE CHROMATOGRAPHIC MATRICES [J].
HJERTEN, S ;
LI, YM ;
LIAO, JL ;
MOHAMMAD, J ;
NAKAZATO, K ;
PETTERSSON, G .
NATURE, 1992, 356 (6372) :810-811
[6]  
HJERTEN S, 1962, ARCH BIOCHEM BIOPHYS, P147
[7]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY ON CONTINUOUS POLYMER BEDS [J].
HJERTEN, S ;
LIAO, JL ;
ZHANG, R .
JOURNAL OF CHROMATOGRAPHY, 1989, 473 (01) :273-275
[8]  
HJERTEN S, UNPUB
[9]  
HJERTEN S, 1968, METHODS IMMUNOLOGY I, V2, P142
[10]  
HJERTEN S, 1992, 1992 P WURZB C WURZB, P93