HIGH SPATIAL RESOLUTION MWPC SYSTEMS USING ELECTROMAGNETIC DELAY-LINE READOUTS

被引:6
|
作者
SWANSON, FR [1 ]
KUEHNE, FJ [1 ]
FAVALE, AJ [1 ]
机构
[1] GRUMMAN AEROSP CORP,BETHPAGE,NY 11714
关键词
D O I
10.1109/TNS.1973.4326901
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
引用
收藏
页码:160 / 165
页数:6
相关论文
共 50 条
  • [1] METHOD OF IMPROVING POSITION RESOLUTION OBTAINED FROM DELAY-LINE READOUTS OF MWPC
    MORRIS, CL
    HOFFMANN, GW
    NUCLEAR INSTRUMENTS & METHODS, 1978, 153 (2-3): : 599 - 600
  • [2] HIGH-RESOLUTION DELAY-LINE READOUTS FOR MICROCHANNEL PLATES
    SIEGMUND, OHW
    LAMPTON, M
    RAFFANTI, R
    HERRICK, W
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1991, 310 (1-2): : 311 - 316
  • [3] HIGH-RESOLUTION DELAY-LINE READOUTS FOR ASTRONOMICAL SPECTROSCOPY
    SIEGMUND, OHW
    RAFFANTI, R
    STOCK, J
    HERRICK, W
    LAMPTON, M
    INSTITUTE OF PHYSICS CONFERENCE SERIES, 1992, (121): : 123 - 130
  • [4] HIGH SPATIAL RESOLUTION WIRE SPARK-CHAMBER SYSTEM USING ELECTROMAGNETIC DELAY-LINE READOUT
    KUEHNE, FJ
    SWANSON, FR
    FAVALE, AJ
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1973, NS20 (01) : 135 - 139
  • [5] DELAY-LINE MWPC HAZARD SIGNALS INSPECTOR
    TURNER, DB
    KIRSTEN, F
    GUIRAGOSSIAN, ZGT
    SCHILLING, R
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1976, 23 (01) : 286 - 288
  • [6] DELAY-LINE READOUTS FOR HIGH-PURITY GERMANIUM MEDICAL IMAGING CAMERAS
    KAUFMAN, L
    CAMP, DC
    MCQUAID, JH
    ARMANTRO.GA
    SWIERKOW.SP
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1974, NS21 (01) : 652 - 657
  • [7] ENERGY RESOLUTION USING DELAY-LINE DETECTORS
    GABRIEL, A
    DAUVERGNE, F
    NOLTING, HF
    KOCH, MHJ
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 349 (2-3): : 461 - 465
  • [8] BIOMEDICAL APPLICATIONS OF PROPORTIONAL WIRE CHAMBERS WITH DELAY-LINE READOUTS
    KAPLAN, SN
    KAUFMAN, L
    VALENTIN.K
    SPERINDE, J
    PEREZMEN.V
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1972, 17 (04): : 482 - &
  • [9] EVALUATION OF FACTORS CONTRIBUTING TO POSITION ACCURACY IN DELAY-LINE READOUT OF MWPC
    PEREZMENDEZ, V
    GREENSTEIN, M
    ORTENDAHL, D
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1977, 24 (01) : 209 - 212
  • [10] GROOVELESS HIGH-PURITY GERMANIUM GAMMA-RAY CAMERA WITH DELAY-LINE READOUTS
    ARMANTROUT, G
    CAMP, D
    MCQUAID, J
    GALWEY, R
    OKUBO, D
    KAUFMAN, L
    HATTNER, R
    PRICE, D
    SWANN, S
    TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1974, 19 (OCT27): : 45 - 45