ION-SENSITIVE MICROELECTRODE SYSTEM WITH SHORT RESPONSE-TIME

被引:3
|
作者
MUCKENHOFF, K
SCHREIBER, S
DESANTIS, A
OKADA, Y
SCHEID, P
机构
[1] Institut für Physiologie, Ruhr-Universität Bochum
关键词
ION-SENSITIVE MICROELECTRODE; INTRACELLULAR ION ACTIVITY; FAST PH MEASUREMENT; FREQUENCY EQUALIZATION TECHNIQUE; FAST SOLUTION CHANGE;
D O I
10.1016/0165-0270(94)90004-3
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The measurement of changes in ion activity (e.g., pH) in neurons requires fine tip-sized double-barreled microelectrodes: one channel being equipped with an ion-selective liquid membrane, the other used for measurement of the membrane potential. The limited bandwidth and the differing transfer functions for electrical and ionic signals necessitate frequency response linearization networks to ensure that the output signal of the electrode is a faithful image of the input signal. We have developed a linearization network to ensure a rapid response time for ion-sensitive microelectrodes. To test the response characteristic we have developed a test system that allows the pH at the electrode tip to be changed within 1 ms. Application of these techniques to electrodes of 1 mu m tip diameter results in a 90% response time to a pH step of similar to 60 ms and of similar to 2 ms with electrodes with 20 mu m tip.
引用
收藏
页码:147 / 153
页数:7
相关论文
共 50 条
  • [1] Studies of selective ion-sensitive microelectrode technique for the detection of neurotransmitter in vivo
    Zheng, XX
    Sun, YH
    PROCEEDINGS OF THE 20TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOL 20, PTS 1-6: BIOMEDICAL ENGINEERING TOWARDS THE YEAR 2000 AND BEYOND, 1998, 20 : 2862 - 2863
  • [2] RESPONSE OF ION-SENSITIVE PLATES AS A FUNCTION OF ION ENERGY
    WOOLSTON, JR
    HONIG, RE
    BOTNICK, EM
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1967, 38 (12): : 1708 - &
  • [3] TRIPLE-BARRELLED ION-SENSITIVE MICROELECTRODE FOR SIMULTANEOUS MEASUREMENTS OF 2 EXTRACELLULAR ION ACTIVITIES
    DUFAU, E
    ACKER, H
    SYLVESTER, D
    MEDICAL PROGRESS THROUGH TECHNOLOGY, 1982, 9 (01) : 33 - 38
  • [4] INTRACELLULAR NA ACTIVITY MEASUREMENTS IN THE CONTROL AND HYPERTROPHIED HEART OF THE FERRET - AN ION-SENSITIVE MICROELECTRODE STUDY
    BAUDET, S
    NOIREAUD, J
    LEOTY, C
    PFLUGERS ARCHIV-EUROPEAN JOURNAL OF PHYSIOLOGY, 1991, 418 (04): : 313 - 318
  • [5] SODIUM CALCIUM EXCHANGE AND INTRACELLULAR CALCIUM BUFFERING IN FERRET MYOCARDIUM - AN ION-SENSITIVE MICROELECTRODE STUDY
    CHAPMAN, RA
    JOURNAL OF PHYSIOLOGY-LONDON, 1986, 373 : 163 - 179
  • [6] ON THE SELECTION OF A SYSTEM WITH LIMIT RESPONSE-TIME
    KOCHUBIEVSKII, ID
    DOKLADY AKADEMII NAUK SSSR, 1980, 250 (06): : 1341 - 1343
  • [7] Response behavior of ion-sensitive hydrogel based on crown ether
    Liu, Xue-Wen
    Zhu, Shen
    Wu, Sheng-Rong
    Wang, Pu
    Han, Guo-Zhi
    COLLOIDS AND SURFACES A-PHYSICOCHEMICAL AND ENGINEERING ASPECTS, 2013, 417 : 140 - 145
  • [8] IMPLANTABLE ION-SENSITIVE TRANSISTORS
    HARAME, DL
    SHOTT, JD
    BOUSSE, L
    MEINDL, JD
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1984, 31 (08) : 572 - 572
  • [9] SYSTEM RESPONSE-TIME AND USER PERFORMANCE
    DANNENBRING, GL
    IEEE TRANSACTIONS ON SYSTEMS MAN AND CYBERNETICS, 1984, 14 (03): : 473 - 478
  • [10] FET ION-SENSITIVE SENSORS
    EBERHART, RC
    IEEE ENGINEERING IN MEDICINE AND BIOLOGY MAGAZINE, 1985, 4 (01): : 27 - 30