PALLADIUM NITRATE MAGNESIUM-NITRATE MODIFIER FOR ELECTROTHERMAL ATOMIC-ABSORPTION SPECTROMETRY .3. DETERMINATION OF MERCURY IN ENVIRONMENTAL STANDARD REFERENCE MATERIALS

被引:54
作者
WELZ, B
SCHLEMMER, G
MUDAKAVI, JR
机构
关键词
ELECTROTHERMAL ATOMIC ABSORPTION SPECTROMETRY; PALLADIUM MODIFIER; MERCURY DETERMINATION; SODIUM CHLORIDE INTERFERENCE; ENVIRONMENTAL SAMPLES;
D O I
10.1039/ja9920700499
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A single addition of 15-mu-g of palladium is sufficient for 40-60 determinations of mercury if the graphite tube is not heated to temperatures higher than 1500-degrees-C in the cleaning step. A pyrolysis temperature of 400-degrees-C can be used without any loss of mercury, and a characteristic mass of 0.1 ng of mercury was obtained for an atomization temperature of 1000-degrees-C. Interferences caused by high sodium chloride concentrations could be eliminated by using a mixture of 95% argon and 5% hydrogen as the purge gas. Mercury could be determined accurately in Aquatic Plant, Albacore Tuna, River Sediment and Coal Fly Ash reference materials.
引用
收藏
页码:499 / 503
页数:5
相关论文
共 48 条
[31]   DIRECT DETERMINATION OF MANGANESE IN SEA-WATER BY ELECTROTHERMAL ATOMIC-ABSORPTION SPECTROMETRY WITH SODIUM-HYDROXIDE AS CHEMICAL MODIFIER FOR INTERFERENCE REMOVAL [J].
LAN, CR ;
ALFASSI, ZB .
ANALYST, 1994, 119 (05) :1033-1035
[32]   DETERMINATION OF SELENIUM IN ACID DIGESTED MARINE SAMPLES BY ELECTROTHERMAL ATOMIC-ABSORPTION SPECTROMETRY WITH CONTINUUM SOURCE BACKGROUND CORRECTION AND NICKEL AS A CHEMICAL MODIFIER [J].
MAAGE, A ;
JULSHAMN, K ;
ANDERSEN, KJ .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1991, 6 (04) :277-281
[33]   Investigation of interference mechanisms of nickel chloride on copper determination and of colloidal palladium as modifier in electrothermal atomic absorption spectrometry using a dual cavity platform [J].
Akman, S ;
Welz, B ;
Tokman, N .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2005, 60 (9-10) :1349-1356
[34]   DETERMINATION OF LEAD IN BIOLOGICAL-MATERIALS BY MICROWAVE-ASSISTED MINERALIZATION AND FLOW-INJECTION ELECTROTHERMAL ATOMIC-ABSORPTION SPECTROMETRY [J].
BURGUERA, JL ;
BURGUERA, M .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1993, 8 (02) :235-241
[35]   Solvent-based de-emulsification dispersive liquid-liquid microextraction of palladium in environmental samples and determination by electrothermal atomic absorption spectrometry [J].
Majidi, Behrooz ;
Shemirani, Farzaneh .
TALANTA, 2012, 93 :245-251
[36]   DETERMINATION OF CADMIUM IN WHOLE-BLOOD AND URINE BY ELECTROTHERMAL ATOMIC-ABSORPTION SPECTROMETRY USING PALLADIUM-BASED MODIFIERS AND IN-SITU DECONTAMINATION [J].
MOREIRA, FDR ;
CURTIUS, AJ ;
DECAMPOS, RC .
ANALYST, 1995, 120 (03) :947-950
[37]   DETERMINATION OF CADMIUM IN ENVIRONMENTAL-SAMPLES BY ELECTROTHERMAL ATOMIC-ABSORPTION SPECTROMETRY USING A TANTALUM-FOIL PLATFORM WITH THE POSSIBILITY OF STANDARDLESS ANALYSIS [J].
MA, YZ ;
BAI, JA ;
WANG, JZ ;
LI, ZK ;
ZHU, L ;
LI, YQ ;
ZHENG, H ;
LI, BW .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1992, 7 (02) :425-431
[38]   The use of tungsten-rhodium permanent chemical modifier for cadmium determination in decomposed samples of biological materials and sediments by electrothermal atomic absorption spectrometry [J].
Lima, ÉC ;
Barbosa, F ;
Krug, FJ .
ANALYTICA CHIMICA ACTA, 2000, 409 (1-2) :267-274
[39]   On the re-assessment of the optimum conditions for the determination of platinum, palladium and rhodium in environmental samples by electrothermal atomic absorption spectrometry and microwave digestion [J].
Tsogas, George Z. ;
Giokas, Dimosthenis L. ;
Vlessidis, Athanasios G. ;
Evmiridis, Nicholaos P. .
TALANTA, 2008, 76 (03) :635-641
[40]   Noble metals as permanent chemical modifiers for the determination of mercury in environmental reference materials using solid sampling graphite furnace atomic absorption spectrometry and calibration against aqueous standards [J].
da Silva, AF ;
Welz, B ;
Curtius, AJ .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2002, 57 (12) :2031-2045