DEVELOPING GLUCOSE SENSORS FOR IN-VIVO USE

被引:41
作者
PICKUP, J
机构
关键词
D O I
10.1016/0167-7799(93)90016-3
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
The potential uses for in vivo glucose sensors in patients with diabetes mellitus include an alarm for low blood-glucose concentrations, a continuous read-out of glucose levels and as part of a feedback-controlled insulin delivery system (artificial pancreas). Most experience has been with implanted amperometric enzyme electrodes, though sensors based on field-effect transistors (FETs) show promise for the future. Sensing responses at the subcutaneous site correlate with plasma-glucose values, but there are often problems of calibration and drift. Implantable glucose sensors are not therefore in routine clinical use. Non-invasive glucose sensing based on near-infrared spectroscopy is being actively investigated as an alternative strategy.
引用
收藏
页码:285 / 291
页数:7
相关论文
共 34 条
[1]  
ABEL P, 1984, BIOMED BIOCHIM ACTA, V43, P577
[2]   AMPEROMETRIC ENZYME ELECTRODES .2. CONDUCTING SALTS AS ELECTRODE MATERIALS FOR THE OXIDATION OF GLUCOSE-OXIDASE [J].
ALBERY, WJ ;
BARTLETT, PN ;
CRASTON, DH .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1985, 194 (02) :223-235
[3]   APPLICATION OF CHRONIC INTRAVASCULAR BLOOD-GLUCOSE SENSOR IN DOGS [J].
ARMOUR, JC ;
LUCISANO, JY ;
MCKEAN, BD ;
GOUGH, DA .
DIABETES, 1990, 39 (12) :1519-1526
[4]   DETERMINATION OF PHYSIOLOGICAL LEVELS OF GLUCOSE IN AN AQUEOUS MATRIX WITH DIGITALLY FILTERED FOURIER-TRANSFORM NEAR-INFRARED SPECTRA [J].
ARNOLD, MA ;
SMALL, GW .
ANALYTICAL CHEMISTRY, 1990, 62 (14) :1457-1464
[5]  
ASSOLANTVINET CH, 1986, ANAL LETT, V19, P875
[6]   DESIGN AND INVITRO STUDIES OF A NEEDLE-TYPE GLUCOSE SENSOR FOR SUBCUTANEOUS MONITORING [J].
BINDRA, DS ;
ZHANG, YN ;
WILSON, GS ;
STERNBERG, R ;
THEVENOT, DR ;
MOATTI, D ;
REACH, G .
ANALYTICAL CHEMISTRY, 1991, 63 (17) :1692-1696
[7]   FERROCENE-MEDIATED ENZYME ELECTRODE FOR AMPEROMETRIC DETERMINATION OF GLUCOSE [J].
CASS, AEG ;
DAVIS, G ;
FRANCIS, GD ;
HILL, HAO ;
ASTON, WJ ;
HIGGINS, IJ ;
PLOTKIN, EV ;
SCOTT, LDL ;
TURNER, APF .
ANALYTICAL CHEMISTRY, 1984, 56 (04) :667-671
[8]   NEEDLE ENZYME ELECTRODES FOR BIOLOGICAL STUDIES [J].
CHURCHOUSE, SJ ;
BATTERSBY, CM ;
MULLEN, WH ;
VADGAMA, PM .
BIOSENSORS, 1986, 2 (06) :325-342
[9]   SUBCUTANEOUS IMPLANTATION OF A FERROCENE-MEDIATED GLUCOSE SENSOR IN PIGS [J].
CLAREMONT, DJ ;
SAMBROOK, IE ;
PENTON, C ;
PICKUP, JC .
DIABETOLOGIA, 1986, 29 (11) :817-821
[10]   ASSESSMENT OF SUBCUTANEOUS GLUCOSE-CONCENTRATION - VALIDATION OF THE WICK TECHNIQUE AS A REFERENCE FOR IMPLANTED ELECTROCHEMICAL SENSORS IN NORMAL AND DIABETIC DOGS [J].
FISCHER, U ;
ERTLE, R ;
ABEL, P ;
REBRIN, K ;
BRUNSTEIN, E ;
VONDORSCHE, HH ;
FREYSE, EJ .
DIABETOLOGIA, 1987, 30 (12) :940-945