COMPARISON OF BIOIMPEDANCE AND THERMODILUTION METHODS FOR DETERMINING CARDIAC-OUTPUT - EXPERIMENTAL AND CLINICAL-STUDIES - UPDATE

被引:8
作者
SPINALE, FG
REINES, HD
CRAWFORD, FA
机构
[1] Division of Cardiothoracic Surgery, Medical University of South Carolina, Charleston, SC
关键词
D O I
10.1016/0003-4975(95)00170-P
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The changes in electrical bioimpedance caused by the blood flow through a thoracic segment may be measured using a series of electrodes placed at opposing ends of this segment. Cardiac output (CO) is calculated by computer as the change in bioimpedance over time. This study was performed to determine the accuracy of bioimpedance CO (CObi) compared with standard thermodilution CO (COtd) in an animal model and in patients. COtd was determined using a thermodilution CO computer, anc CObi was calculated with a bioimpedance computer in 10 dogs at baseline and at 5-minute intervals following the injection of 7 mEq of calcium chloride. A high correlation between COtd and CObi was observed (r=0.91, p<0.001) over a range of 2.5 to 6 L/min. Thirty-three paired observations using the CObi and COtd methods were performed in 10 patients following elective coronary artery bypass surgery. A significant correlation between the two methods was determined with a CO range of 2.1 to 7.8 L/min (r=0.77, p<0.001). CObi became inaccurate with severe tachycardia (pulse, 180/min), low Co, or frequent arrhythmias. These results indicate that this technique provides a continuous noninvasive method of determining CO that is comparable with thermodilution techniques. The technique of CObi holds promise for widespread use when continuous and noninvasive monitoring of CO is necessary.
引用
收藏
页码:483 / 484
页数:2
相关论文
共 50 条
[21]   CONTINUOUS THERMODILUTION CARDIAC-OUTPUT - AGREEMENT WITH FICK AND BOLUS THERMODILUTION METHODS [J].
THRUSH, D ;
DOWNS, JB ;
SMITH, RA .
JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 1995, 9 (04) :399-404
[22]   ELECTRICAL BIOIMPEDENCE AS A METHOD FOR CONTINUOUS NONINVASIVE ESTIMATION OF CARDIAC-OUTPUT - EXPERIMENTAL AND CLINICAL-STUDIES [J].
SPINALE, F ;
REINES, HD ;
CRAWFORD, FA .
CRITICAL CARE MEDICINE, 1987, 15 (04) :364-364
[23]   COMPARISON OF CARDIAC-OUTPUT MEASURED WITH CONTINUOUS THERMODILUTION AND CARDIAC-OUTPUT CALCULATED WITH THE FICKS PRINCIPLE [J].
BIZOUARN, P ;
BLANLOEIL, Y ;
PINAUD, M .
ANNALES FRANCAISES D ANESTHESIE ET DE REANIMATION, 1994, 13 (05) :685-689
[24]   SIMULTANEOUS MEASUREMENT OF CARDIAC-OUTPUT BY THERMODILUTION, THORACIC ELECTRICAL BIOIMPEDANCE AND DOPPLER ULTRASOUND [J].
CASTOR, G ;
KLOCKE, RK ;
STOLL, M ;
HELMS, J ;
NIEDERMARK, I .
BRITISH JOURNAL OF ANAESTHESIA, 1994, 72 (01) :133-138
[25]   COMPARISON OF THE TRANS-THORACIC ELECTRICAL BIOIMPEDANCE TO THE THERMODILUTION TECHNIQUE FOR MEASURING CARDIAC-OUTPUT IN NEONATAL PIGLETS [J].
VO, CH ;
SINGH, S ;
JURATSCH, C ;
WAFFARN, F .
CLINICAL RESEARCH, 1989, 37 (01) :A210-A210
[26]   VALIDITY OF THERMODILUTION CARDIAC-OUTPUT DETERMINATION EXPERIMENTAL STUDIES WITH AND WITHOUT PULMONARY INSUFFICIENCY [J].
BEYER, J ;
LAMBERTI, J ;
REPLOGLE, R .
CLINICAL RESEARCH, 1975, 23 (04) :A468-A468
[27]   COMPARISON BETWEEN THERMODILUTION, ELECTROMAGNETIC AND DOPPLER METHODS FOR CARDIAC-OUTPUT MEASUREMENT IN RABBIT [J].
WHITE, SW ;
MCRITCHIE, RJ ;
PORGES, WL .
CLINICAL AND EXPERIMENTAL PHARMACOLOGY AND PHYSIOLOGY, 1974, 1 (03) :175-182
[28]   Comparison of cardiac output by bioimpedance, thermodilution, and reverse-fick [J].
Engoren, M .
CRITICAL CARE MEDICINE, 2002, 30 (12) :A68-A68
[29]   CARDIAC-OUTPUT MEASUREMENT - LACK OF AGREEMENT BETWEEN THERMODILUTION AND THORACIC ELECTRIC BIOIMPEDANCE IN 2 CLINICAL SETTINGS [J].
ATALLAH, MM ;
DEMAIN, AD .
JOURNAL OF CLINICAL ANESTHESIA, 1995, 7 (03) :182-185
[30]   Comparison of cardiac output determined by bioimpedance, thermodilution, and the Fick method [J].