COMPARISON OF BIOIMPEDANCE AND THERMODILUTION METHODS FOR DETERMINING CARDIAC-OUTPUT - EXPERIMENTAL AND CLINICAL-STUDIES - UPDATE

被引:8
作者
SPINALE, FG
REINES, HD
CRAWFORD, FA
机构
[1] Division of Cardiothoracic Surgery, Medical University of South Carolina, Charleston, SC
关键词
D O I
10.1016/0003-4975(95)00170-P
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The changes in electrical bioimpedance caused by the blood flow through a thoracic segment may be measured using a series of electrodes placed at opposing ends of this segment. Cardiac output (CO) is calculated by computer as the change in bioimpedance over time. This study was performed to determine the accuracy of bioimpedance CO (CObi) compared with standard thermodilution CO (COtd) in an animal model and in patients. COtd was determined using a thermodilution CO computer, anc CObi was calculated with a bioimpedance computer in 10 dogs at baseline and at 5-minute intervals following the injection of 7 mEq of calcium chloride. A high correlation between COtd and CObi was observed (r=0.91, p<0.001) over a range of 2.5 to 6 L/min. Thirty-three paired observations using the CObi and COtd methods were performed in 10 patients following elective coronary artery bypass surgery. A significant correlation between the two methods was determined with a CO range of 2.1 to 7.8 L/min (r=0.77, p<0.001). CObi became inaccurate with severe tachycardia (pulse, 180/min), low Co, or frequent arrhythmias. These results indicate that this technique provides a continuous noninvasive method of determining CO that is comparable with thermodilution techniques. The technique of CObi holds promise for widespread use when continuous and noninvasive monitoring of CO is necessary.
引用
收藏
页码:483 / 484
页数:2
相关论文
共 50 条
[11]   COMPARISON OF CARDIAC-OUTPUT MEASUREMENT BY NONINVASIVE ELECTRICAL BIOIMPEDANCE WITH THERMODILUTION IN CRITICALLY ILL PATIENTS [J].
APPEL, PL ;
SHOEMAKER, WC ;
KRAM, HB ;
MACKABEE, JR ;
FLEMING, AW .
CRITICAL CARE MEDICINE, 1986, 14 (04) :380-380
[12]   NONINVASIVE MEASUREMENT OF CARDIAC-OUTPUT BY THORACIC ELECTRICAL BIOIMPEDANCE - A STUDY OF REPRODUCIBILITY AND COMPARISON WITH THERMODILUTION [J].
JEWKES, C ;
SEAR, JW ;
VERHOEFF, F ;
SANDERS, DJ ;
FOEX, P .
BRITISH JOURNAL OF ANAESTHESIA, 1991, 67 (06) :788-794
[13]   ISSUES IN METHODS AND MEASUREMENT OF THERMODILUTION CARDIAC-OUTPUT [J].
SOMMERS, MS ;
WOODS, SL ;
COURTADE, MA .
NURSING RESEARCH, 1993, 42 (04) :228-233
[14]   CARDIAC-OUTPUT DETERMINATIONS IN THE PIG - THORACIC ELECTRICAL BIOIMPEDANCE VERSUS THERMODILUTION [J].
JIVEGARD, L ;
FRID, I ;
HALJAMAE, H ;
HOLM, J ;
HOLM, S ;
WICKSTROM, I .
CRITICAL CARE MEDICINE, 1990, 18 (09) :995-998
[15]   COMPARISON OF THERMODILUTION CARDIAC-OUTPUT MEASURED BY 2 DIFFERENT CARDIAC-OUTPUT COMPUTERS [J].
MATTHEW, EB ;
VENDER, JS .
ANESTHESIOLOGY, 1986, 65 (3A) :A141-A141
[16]   NONINVASIVE CARDIAC-OUTPUT - SIMULTANEOUS COMPARISON OF 2 DIFFERENT METHODS WITH THERMODILUTION [J].
WONG, DH ;
TREMPER, KK ;
STEMMER, EA ;
OCONNOR, D ;
WILBUR, S ;
ZACCARI, J ;
REEVES, C ;
WEIDOFF, P ;
TRUJILLO, RJ .
ANESTHESIOLOGY, 1990, 72 (05) :784-792
[17]   COMPARISON OF THERMODILUTION AND FICK METHODS FOR MEASUREMENT OF CARDIAC-OUTPUT IN TRICUSPID REGURGITATION [J].
KONISHI, T ;
NAKAMURA, Y ;
MORII, I ;
HIMURA, Y ;
KUMADA, T ;
KAWAI, C .
AMERICAN JOURNAL OF CARDIOLOGY, 1992, 70 (04) :538-539
[18]   COMPARISON OF CONTINUAL THERMODILUTION CARDIAC-OUTPUT WITH ELECTROMAGNETOMETRY [J].
HOGUE, CW ;
CERZA, RF ;
ROSENBLOOM, M ;
LAPPAS, DG .
ANESTHESIOLOGY, 1993, 79 (3A) :A467-A467
[19]   NONINVASIVE CARDIAC-OUTPUT DETERMINATION - A COMPARISON WITH THERMODILUTION [J].
BOLEY, TM ;
CURTIS, JJ ;
WALLS, JT ;
REID, JC .
HEART & LUNG, 1985, 14 (03) :289-289
[20]   CLINICAL APPLICATIONS OF THERMODILUTION CARDIAC-OUTPUT DETERMINATIONS [J].
WEISEL, RD ;
VITO, L ;
DENNIS, RC ;
BERGER, RL ;
HECHTMAN, HB .
AMERICAN JOURNAL OF SURGERY, 1975, 129 (04) :449-454