USE OF A TOTAL IONIC STRENGTH ADJUSTMENT BUFFER FOR ELECTRODE DETERMINATION OF FLUORIDE IN WATER SUPPLIES

被引:273
作者
FRANT, MS
ROSS, JW
机构
[1] Orion Research Inc., Cambridge
关键词
D O I
10.1021/ac60263a005
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
[No abstract available]
引用
收藏
页码:1169 / &
相关论文
共 12 条
[1]  
ANDELMAN JB, 1967, 40 WAT POLL CONTR FE
[2]   MODIFICATION OF FLUORIDE ACTIVITY ELECTRODE FOR MICROCHEMICAL ANALYSIS [J].
DURST, RA ;
TAYLOR, JK .
ANALYTICAL CHEMISTRY, 1967, 39 (12) :1483-&
[3]  
ELFERS IA, UNPUBLISHED DATA
[4]   ELECTRODE FOR SENSING FLUORIDE ION ACTIVITY IN SOLUTION [J].
FRANT, MS ;
ROSS, JW .
SCIENCE, 1966, 154 (3756) :1553-&
[5]  
FRANT MS, 1967, PLATING, V54, P702
[6]  
KNOWLTON K, 1967, PERSONAL COMMUNICATI
[7]  
LIGHT TS, 1967, MAR PITTSB C AN CHEM
[9]   LANTHANUM FLUORIDE ELECTRODE RESPONSE IN AQUEOUS CHLORIDE MEDIA [J].
MESMER, RE .
ANALYTICAL CHEMISTRY, 1968, 40 (02) :443-&
[10]  
MORRIS MD, 1967, ANAL CHEM, V39, P1776