Analysis of the Performance of a Standardized Method for the Polishing of Methacrylic Resins

被引:14
作者
Corsalini, Massimo [1 ]
Boccaccio, Antonio [2 ]
Lamberti, Luciano [2 ]
Pappalettere, Carmine [2 ]
Catapano, Santo [3 ]
Carossa, Stefano [4 ]
机构
[1] Univ Bari, Sch Dent, Bari, Italy
[2] Politecn Bari, Dept Mech & Management Engn, Bari, Italy
[3] Univ Ferrara, Sch Dent, Ferrara, Italy
[4] Univ Turin, Sch Dent, Turin, Italy
关键词
Methacrylic resin; surface roughness; polishing technique; isoparallelometer;
D O I
10.2174/1874210600903010233
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Adhesion of micro-organisms to resin surface may be caused by inadequate polishing. Most of the studies published in literature are relative to manually prepared samples and do not take into account that test repeatability is not guaranteed a priori since skills may change from one operator to another and the quality of the work done by the same expert operator may depend on "human" factors such as the level of attention, wrist trembling, etc. This paper aims to investigate on the efficiency and reliability of a standardized protocol for polishing methacrylic resins. For that purpose, five different methacrylic resins are considered. For each resin, 20 specimens are realized: 10 are polished by the same expert operator and 10 are polished by means of a mechanical system comprised of a milling tool, a mobile support for samples and a micrometric advance isoparallelometer. Roughness measurements are carried out with a +/- 0.01 mu m resolution profilometer. An extensive statistical analysis is conducted on a population of 100 specimens. Two-way Analysis of Variance (ANOVA) is carried out taking the type of resin (i) and the polishing technique (ii) as predictors in order to evaluate how those variables will finally affect the roughness of the polished surface. The significance of the variable interaction term is assessed. The null hypothesis Ho where response is independent from individual factors as well as from their interaction is assumed to hold true for p-values>0.05 (interval of confidence of the 95%). Experimental data confirm that mechanical polishing leads to obtaining surfaces of much more uniform quality. In fact, statistical dispersion of roughness parameters can decrease significantly. This behavior is observed for all of the tested resins. Therefore, the new approach can eliminate the influence of "human" factors thus making it possible to assess the inherent features of each resin and compare different dental materials submitted to polishing.
引用
收藏
页码:233 / 240
页数:8
相关论文
共 18 条
[1]  
[Anonymous], 2008, 207951 ISO
[2]  
Berger Julie C, 2006, J Prosthodont, V15, P180, DOI 10.1111/j.1532-849X.2006.00098.x
[3]  
Corsalini M, 2008, INT J PROSTHODONT, V21, P409
[4]  
Ellyn F, 1997, FATIGUE DAMAGE CRACK
[5]   Surface roughness of auto polymerized acrylic resin according to different manipulation and polishing methods [J].
Gloncalves, Tatiana Siqueira ;
Spohr, Ana Maria ;
de Souza, Rodrigo Matos ;
de Menezes, Luciane Macedo .
ANGLE ORTHODONTIST, 2008, 78 (05) :931-934
[6]   Surface roughness and gloss of dental materials as a function of force and polishing time in vitro [J].
Heintze, SD ;
Forjanic, M ;
Rousson, V .
DENTAL MATERIALS, 2006, 22 (02) :146-165
[7]  
ISO 4287, 1997, 4287 ISO
[8]   Effects of polishing techniques on the surface roughness of acrylic denture base resins [J].
Kuhar, M ;
Funduk, N .
JOURNAL OF PROSTHETIC DENTISTRY, 2005, 93 (01) :76-85
[9]  
Alves PVM, 2007, ANGLE ORTHOD, V77, P528, DOI 10.2319/0003-3219(2007)077[0528:SROARA]2.0.CO
[10]  
2