ANALYSIS OF THE SPATIAL-FREQUENCY-DEPENDENT DQE OF OPTICALLY COUPLED DIGITAL MAMMOGRAPHY DETECTORS

被引:65
|
作者
MAIDMENT, ADA
YAFFE, MJ
机构
[1] UNIV TORONTO,DEPT MED BIOPHYS,TORONTO M4N 3M5,ON,CANADA
[2] SUNNYBROOK HLTH SCI CTR,DIV RES,TORONTO M4N 3M5,ON,CANADA
[3] UNIV TORONTO,DEPT RADIOL,TORONTO M4N 3M5,ON,CANADA
关键词
DIGITAL MAMMOGRAPHY; X-RAY DETECTOR; OPTICAL COUPLING EFFICIENCY; MODULATION TRANSFER FUNCTION; NOISE POWER SPECTRA; DETECTIVE QUANTUM EFFICIENCY;
D O I
10.1118/1.597331
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The effect of optical coupling efficiency on the spatial-frequency-dependent propagation of signal and noise is considered for x-ray image detectors for digital mammography in which a phosphor screen is optically coupled to a charge-coupled device (CCD) image array. For experimental purposes, optical coupling between a Gd2O2S:Tb phosphor screen and a CCD image array was provided by relay lenses. Neutral density filters were inserted between the lenses to vary the optical coupling efficiency without altering the inherent spatial resolution. The total coupling efficiency, defined as the number of electrons (e-) recorded in the CCD per x-ray interaction in the phosphor, was calculated in each case. The modulation transfer function, and the contributions to the total noise power spectrum (NPS) of x-ray quantum noise, secondary quantum noise, and inherent detector noise were measured as a function of coupling efficiency. These data were used to calculate the spatial-frequency-dependent detective quantum efficiency [DOE(f)]. The NPS due to x-ray quantum noise had a significant spatial-frequency dependence for coupling efficiencies of more than 9 e- per x-ray interaction, but little spatial-frequency dependence for coupling efficiencies of less than 2 e- per x-ray interaction. These results indicate that to preserve high spatial-frequency values of DQE(f), and to ensure that images are x-ray quantum-noise limited at high spatial frequencies, a coupling efficiency on the order of 10 e- per x-ray interaction is required. This is contrary to the common belief, based on zero spatial-frequency analysis, that a coupling efficiency on the order of 1 e- per x-ray interaction is sufficient to acquire x-ray quantum-noise-limited images.
引用
收藏
页码:721 / 729
页数:9
相关论文
共 50 条
  • [21] Silicon microstrip detectors for digital mammography - evaluation and spatial resolution study
    Mali, T
    Cindro, V
    Mikuz, M
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 460 (01): : 76 - 80
  • [22] DESIGN CONSIDERATIONS IN OPTICALLY COUPLED DIGITAL X-RAY-DETECTORS
    MAIDMENT, AD
    YAFFE, MJ
    RADIOLOGY, 1995, 197 : 357 - 357
  • [23] THE CRITICAL DURATION IN SPATIAL-FREQUENCY-DEPENDENT VISIBLE PERSISTENCE AND SPECIFIC READING-DISABILITY
    SLAGHUIS, WL
    LOVEGROVE, WJ
    BULLETIN OF THE PSYCHONOMIC SOCIETY, 1986, 24 (06) : 416 - 418
  • [24] The concept of spatial frequency depending DQE and its application to a comparison of two detectors used in transvenous coronary angiography
    Menk, RH
    Thomlinson, W
    Gmur, N
    Zhong, Z
    Chapman, D
    Arfelli, F
    Dix, WR
    Graeff, W
    Lohmann, M
    Illing, G
    Schildwachter, L
    Reime, B
    Kupper, W
    Hamm, C
    Giacomini, JC
    Gordon, HJ
    Rubenstein, E
    Dervan, J
    Besch, HJ
    Walenta, AH
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1997, 398 (2-3): : 351 - 367
  • [25] THE EFFECT OF FIELD SIZE AND LUMINANCE ON SPATIAL-FREQUENCY-DEPENDENT VISIBLE PERSISTENCE AND SPECIFIC READING-DISABILITY
    SLAGHUIS, WL
    LOVEGROVE, WS
    BULLETIN OF THE PSYCHONOMIC SOCIETY, 1987, 25 (01) : 38 - 40
  • [26] Quantum noise in digital x-ray image detectors with optically coupled scintillators
    Flynn, MJ
    Hames, SM
    Wilderman, SJ
    Ciarelli, JJ
    1995 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD, VOLS 1-3, 1996, : 1622 - 1626
  • [27] Quantum noise in digital X-ray image detectors with optically coupled scintillators
    Flynn, MJ
    Hames, SM
    Wilderman, SJ
    Ciarelli, JJ
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1996, 43 (04) : 2320 - 2325
  • [28] Analysis of angular dependent spatial frequency response of Digital Coplanar Translational Laminography
    Silva, Weslley
    Zscherpel, Uwe
    Ewert, Uwe
    Lopes, Ricardo
    NDT & E INTERNATIONAL, 2021, 124
  • [29] SPATIAL-FREQUENCY-DEPENDENT CHANGES IN THE HUMAN PATTERN ELECTRORETINOGRAM AFTER ACUTE ACETYL-L-CARNITINE ADMINISTRATION
    FALSINI, B
    PORCIATTI, V
    BOLZANI, R
    MARCHIONNI, A
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 1991, 229 (03) : 262 - 266
  • [30] A comparative analysis of OTF, NPS, and DQE in energy integrating and photon counting digital x-ray detectors
    Acciavatti, Raymond J.
    Maidment, Andrew D. A.
    MEDICAL PHYSICS, 2010, 37 (12) : 6480 - 6495