OPTIMAL TRUNCATION OF DEFIBRILLATION PULSES

被引:60
作者
IRNICH, W
机构
[1] Department of Medical Engineering, Justus-Liebig-University, Giessen
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 1995年 / 18卷 / 04期
关键词
DEFIBRILLATION; EXPONENTIAL PULSE; TRUNCATION; OPTIMIZATION; ELECTROPHYSIOLOGY;
D O I
10.1111/j.1540-8159.1995.tb04662.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The statement that the optimal pulse for defibrillation has not yet been discovered implies that an ideal pulse exists, but that it is different in shape, duration, and energy as compared to pulses of today. The optimum pulse is that which can defibrillate e with lowest energy. Reduction of energy can be reached twofold: by looking for a pulse duration with lowest energy threshold, and by finding the optimal truncation with lowest refibrillating effect. Assuming that there is also a rheobase in defibrillation below which no defibrillating but probably a refibrillating effect exists, the exponential pulse should be truncated if it intersects with the rheobase. Combining the fundamental law of electrostimulation with this boundary condition allows for the mathematical solution of the above problem of optimal energy. Defibrillation con be optimized with respect to pulse duration or tilt and to energy efficiency. The most important parameter in determining other optimized parameters such os output capacitor is the chronaxie. The calculations reveal that the ''concept of constant energy'' does not accurately describe defibrillation, that today's implantable cardioverter defibrillator devices possess refibrillating tilts, that pulse durations should be programmed to values between 4 and 10 msec, and that smaller output capacitors around 30 mu F would minimize the energy requirements. Whether optimized monophasic pulses are inferior or equal to biphasic pulses needs further experimental studies.
引用
收藏
页码:673 / 688
页数:16
相关论文
共 18 条
  • [1] BOURLAND JD, 1978, MED INSTRUM, V12, P45
  • [2] THE PROBABILITY OF DEFIBRILLATION SUCCESS AND THE INCIDENCE OF POSTSHOCK ARRHYTHMIA AS A FUNCTION OF SHOCK STRENGTH
    CATES, AW
    WOLF, PD
    HILLSLEY, RE
    SOUZA, JJ
    SMITH, WM
    IDEKER, RE
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1994, 17 (07): : 1208 - 1217
  • [3] STRENGTH-DURATION CURVES OF FIXED PULSE WIDTH VARIABLE TILT TRUNCATED EXPONENTIAL WAVEFORMS FOR NONTHORACOMY INTERNAL DEFIBRILLATION IN DOGS
    CHAPMAN, PD
    WETHERBEE, JN
    VETTER, JW
    TROUP, P
    SOUZA, J
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1988, 11 (07): : 1045 - 1050
  • [4] ENGINEERING AND PHYSIOLOGICAL CONSIDERATIONS OF DIRECT CAPACITOR-DISCHARGE VENTRICULAR DEFIBRILLATION
    GEDDES, LA
    TACKER, WA
    [J]. MEDICAL & BIOLOGICAL ENGINEERING, 1971, 9 (03): : 185 - &
  • [5] FUNDAMENTAL CRITERIA UNDERLYING THE EFFICACY AND SAFETY OF DEFIBRILLATING CURRENT WAVEFORMS
    GEDDES, LA
    NIEBAUER, MJ
    BABBS, CF
    BOURLAND, JD
    [J]. MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1985, 23 (02) : 122 - 130
  • [6] Hoorweg JL, 1892, PFLUG ARCH EUR J PHY, V52, P87, DOI [10.1007/BF01661875, DOI 10.1007/BF01661875]
  • [7] THE FUNDAMENTAL LAW OF ELECTROSTIMULATION AND ITS APPLICATION TO DEFIBRILLATION
    IRNICH, W
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1990, 13 (11): : 1433 - 1447
  • [8] IRNICH W, 1994, IMPLANTABLE CARDIOVE, P135
  • [9] RESPONSE OF CULTURED MYOCARDIAL-CELLS TO COUNTERSHOCK-TYPE ELECTRIC-FIELD STIMULATION
    JONES, JL
    LEPESCHKIN, E
    JONES, RE
    RUSH, S
    [J]. AMERICAN JOURNAL OF PHYSIOLOGY, 1978, 235 (02): : H214 - H222
  • [10] AMPLITUDE-DURATION RELATION FOR DIRECT VENTRICULAR DEFIBRILLATION WITH RECTANGULAR CURRENT PULSES
    KONING, G
    SCHNEIDER, H
    HOELEN, AJ
    RENEMAN, RS
    [J]. MEDICAL & BIOLOGICAL ENGINEERING, 1975, 13 (03): : 388 - 395