Mid-infrared Quantum Cascade Laser Gas Detection System

被引:0
作者
Lin Bai-yang [1 ]
Dang Jing-min [2 ]
Zheng Chuan-tao [1 ]
Zhang Yu [1 ]
Wang Yi-ding [1 ]
机构
[1] Jilin Univ, Coll Elect Sci & Engn, State Key Lab Integrated Optoelect, Changchun 130012, Jilin, Peoples R China
[2] Jilin Univ, Coll Biol & Agr Engn, Changchun 130012, Jilin, Peoples R China
基金
国家重点研发计划;
关键词
Optoelectronics; Mid-infrared; Driving circuit; Lock-in amplifier; Quantum cascade laser; Gas detection;
D O I
10.3788/gzxb20184704.0423001
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
To meet the requirement of mid infrared gas detection based on continuous Quantum Cascade Laser (QCL), a board level QCL driver and a lock in amplifier are developed. High precision direct current (DC) bias signal, low frequency saw tooth scan signal and high frequency sine wave modulation signal are generated by a signal generation circuit to control the laser current and scan/modulate laser output wavelength. The developed lock-in amplifier includes a multiple frequency circuit, an orthogonal conversion circuit, and a data-conversion circuit, which detects the second harmonic (2f) signal from the trace gas absorption signal and gains a high signal-to-noise ratio. In addition, in order to improve the stability and reliability of the system, a linear power supply with high stability and a high-performance protection circuit are designed. A QCL with a wavelength of 4.76 mu m developed by the Semiconductor Institute of Chinese Academy of Science is used as a light source, and function verification and gas detection experiments of the electrical system are carried out. The experimental results show that the linearity of laser driver is as high as 0.006 3% , the long-term current stability is 5.0X10(-5), and the long-term power stability of QCL is 5.07 X 10(-4). The lock-in amplifier has an average detection error on the first harmonic (1f) signal of less than 2.4% and an error on the 2f signal of less than 5.5%. Low-concentration carbon monoxide (CO) detection is carried out, and there is a high linearity (R-2 > 0.99) between the amplitude of 2f signal and CO gas concentration in the concentration range of 0-100 ppm. These results confirm that the developed electrical system has good stability and reliability, assuring a safe and reliable mid-infrared CO gas detection.
引用
收藏
页数:8
相关论文
共 18 条
[1]  
Chen Chen, 2011, Journal of Jilin University (Engineering and Technology Edition), V41, P1738
[2]   Large current nanosecond pulse generating circuit for driving semiconductor laser [J].
Chen, Yan-Chao ;
Feng, Yong-Ge ;
Zhang, Xian-Bing .
Guangxue Jingmi Gongcheng/Optics and Precision Engineering, 2014, 22 (11) :3145-3151
[3]   A Review of Mixed Gas Detection System Based on Infrared Spectroscopic Technique [J].
Dang Jing-min ;
Fu Li ;
Yan Zi-hui ;
Zheng Chuan-tao ;
Chang Yu-chun ;
Chen Chen ;
Wang Yi-ding .
SPECTROSCOPY AND SPECTRAL ANALYSIS, 2014, 34 (10) :2851-2857
[4]   Nanosecond driver for multiple pulse-modulated Infrared quantum cascade lasers [J].
Dang, Jing-Min ;
Zhai, Bing ;
Gao, Zong-Li ;
Chen, Chen ;
Wang, Yi-Ding .
Guangxue Jingmi Gongcheng/Optics and Precision Engineering, 2013, 21 (09) :2209-2216
[5]   A near-infrared acetylene detection system based on a 1.534 μm tunable diode laser and a miniature gas chamber [J].
He, Qixin ;
Zheng, Chuantao ;
Liu, Huifang ;
Li, Bin ;
Wang, Yiding ;
Tittel, Frank K. .
INFRARED PHYSICS & TECHNOLOGY, 2016, 75 :93-99
[6]   Tropical cyclones and climate change [J].
Knutson, Thomas R. ;
McBride, John L. ;
Chan, Johnny ;
Emanuel, Kerry ;
Holland, Greg ;
Landsea, Chris ;
Held, Isaac ;
Kossin, James P. ;
Srivastava, A. K. ;
Sugi, Masato .
NATURE GEOSCIENCE, 2010, 3 (03) :157-163
[7]   Application of quantum cascade lasers to trace gas analysis [J].
Kosterev, A. ;
Wysocki, G. ;
Bakhirkin, Y. ;
So, S. ;
Lewicki, R. ;
Fraser, M. ;
Tittel, F. ;
Curl, R. F. .
APPLIED PHYSICS B-LASERS AND OPTICS, 2008, 90 (02) :165-176
[8]   Development of field-deployable QCL sensor for simultaneous detection of ambient N2O and CO [J].
Li, Jingsong ;
Parchatka, Uwe ;
Fischer, Horst .
SENSORS AND ACTUATORS B-CHEMICAL, 2013, 182 :659-667
[9]   Phase shift extraction algorithm with error estimation in phase-shifting interferometry [J].
Liu Q. ;
Yuan D.-C. ;
He J.-G. .
Guangxue Jingmi Gongcheng/Optics and Precision Engineering, 2016, 24 (10) :2565-2571
[10]   QEPAS based ppb-level detection of CO and N2O using a high power CW DFB-QCL [J].
Ma, Yufei ;
Lewicki, Rafal ;
Razeghi, Manijeh ;
Tittel, Frank K. .
OPTICS EXPRESS, 2013, 21 (01) :1008-1019