ACCURATE PSEUDOANALYTICAL SOLUTION FOR STEADY-STATE BIOFILMS

被引:51
作者
SAEZ, PB [1 ]
RITTMANN, BE [1 ]
机构
[1] UNIV ILLINOIS,DEPT CIVIL ENGN,URBANA,IL 61801
关键词
BIOFILMS; KINETICS; STEADY STATE; PSEUDOANALYTICAL SOLUTION;
D O I
10.1002/bit.260390712
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
An extremely accurate pseudoanalytical solution for the flux of substrate into a steady-state biofilm is developed. The standard deviations between the substrate fluxes computed from the pseudoanalytical solution and the numerical solution were less than 2.6%. Additional advantages of the pseudoanalytical solution are that it has no inaccuracies around S(min)* = 1 and it is composed of single continuous functions applicable to the whole S(min)* region.
引用
收藏
页码:790 / 793
页数:4
相关论文
共 7 条
[1]  
CANNON FS, 1991, RES J WATER POLLUT C, V63, P90
[2]  
HEATH MS, 1991, RES J WATER POLLUT C, V63, P91
[3]  
HEATH MS, 1990, RES J WATER POLLUT C, V62, P185
[4]   MODEL OF STEADY-STATE-BIOFILM KINETICS [J].
RITTMANN, BE ;
MCCARTY, PL .
BIOTECHNOLOGY AND BIOENGINEERING, 1980, 22 (11) :2343-2357
[5]   IMPROVED PSEUDOANALYTICAL SOLUTION FOR STEADY-STATE BIOFILM KINETICS [J].
SAEZ, PB ;
RITTMANN, BE .
BIOTECHNOLOGY AND BIOENGINEERING, 1988, 32 (03) :379-385
[6]   ERROR ANALYSIS OF LIMITING-CASE SOLUTIONS TO THE STEADY-STATE-BIOFILM MODEL [J].
SAEZ, PB ;
RITTMANN, BE .
WATER RESEARCH, 1990, 24 (10) :1181-1185
[7]   UNIFIED ANALYSIS OF BIOFILM KINETICS [J].
SUIDAN, MT ;
WANG, YT .
JOURNAL OF ENVIRONMENTAL ENGINEERING-ASCE, 1985, 111 (05) :634-646