FLUORESCENCE-LABELED PEPTIDES AS ISOELECTRIC POINT (PI) MARKERS IN CAPILLARY ISOELECTRIC-FOCUSING WITH FLUORESCENCE DETECTION

被引:25
作者
SHIMURA, K
KASAI, K
机构
[1] Faculty of Pharmaceutical Sciences, Teikyo University, Sagamiko, Kanagawa
关键词
FLUORESCENT PI MARKER; ISOELECTRIC FOCUSING; CAPILLARY ELECTROPHORESIS; LASER-INDUCED FLUORESCENCE; FLUORESCENCE-LABELED PEPTIDES;
D O I
10.1002/elps.11501601245
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Commercially available peptides, mostly angiotensin derivatives, were labeled at their N-terminal amino group with 5-carboxytetramethylrhodamine succinimidyl ester, to obtain fluorescent pI markers for capillary isoelectric focusing with fluorescence detection. The labeled peptides were purified by reversed-phase chromatography. They were well separated on isoelectric focusing in a polyacrylamide gel slab and their pIs were determined by comigration with protein-pI markers. The fluorescent markers could be detected as sharp peaks in capillary isoelectric focusing with laser-induced fluorescence detection (He-Ne laser, 1 mW 543.5 nm). The detection limit was found to be around 3 X 10(-12) M (0.8 amol). Tetramethylrhodamine-labeled pea lectin (3 pg) was subjected to capillary isoelectric focusing and the pIs of the fluorescent derivatives of the lectin were determined by using the fluorescence-labeled peptides as pI markers.
引用
收藏
页码:1479 / 1484
页数:6
相关论文
共 15 条
[1]   A BRIEF SURVEY OF METHODS FOR PREPARING PROTEIN CONJUGATES WITH DYES, HAPTENS, AND CROSS-LINKING REAGENTS [J].
BRINKLEY, M .
BIOCONJUGATE CHEMISTRY, 1992, 3 (01) :2-13
[2]   ON HETEROGENEITY OF BEEF HEART CYTOCHROME C .4. ISOELECTRIC FRACTIONATION BY ELECTROLYSIS IN A NATURAL PH-GRADIENT [J].
FLATMARK, T ;
VESTERBERG, O .
ACTA CHEMICA SCANDINAVICA, 1966, 20 (06) :1497-+
[3]  
Hanabe T, 1982, KAGAKU NO RYOIKI, V36, P470
[4]   HIGH-PERFORMANCE ELECTROPHORESIS - ELIMINATION OF ELECTROENDOSMOSIS AND SOLUTE ADSORPTION [J].
HJERTEN, S .
JOURNAL OF CHROMATOGRAPHY, 1985, 347 (02) :191-198
[5]   THEORETICAL AND EXPERIMENTAL-STUDY OF HIGH-PERFORMANCE ELECTROPHORETIC MOBILIZATION OF ISOELECTRICALLY FOCUSED PROTEIN ZONES [J].
HJERTEN, S ;
LIAO, JL ;
YAO, K .
JOURNAL OF CHROMATOGRAPHY, 1987, 387 :127-138
[6]  
HJERTEN S, 1995, J CHROMATOGR, V346, P265
[7]   PEPTIDE-MAPPING USING EOF-DRIVEN CAPILLARY ISOELECTRIC-FOCUSING [J].
MAZZEO, JR ;
MARTINEAU, JA ;
KRULL, IS .
ANALYTICAL BIOCHEMISTRY, 1993, 208 (02) :323-329
[8]  
MEANS GE, 1971, CHEM MODIFICATION PR, pCH5
[9]   HISTORICAL AND THEORETICAL ASPECTS OF ISOELECTRIC FOCUSING [J].
RILBE, H .
ANNALS OF THE NEW YORK ACADEMY OF SCIENCES, 1973, 209 (JUN15) :11-22
[10]   AFFINITY PROBE CAPILLARY ELECTROPHORESIS - ANALYSIS OF RECOMBINANT HUMAN GROWTH-HORMONE WITH A FLUORESCENT-LABELED ANTIBODY FRAGMENT [J].
SHIMURA, K ;
KARGER, BL .
ANALYTICAL CHEMISTRY, 1994, 66 (01) :9-15