USE OF ENZYMATIC REACTORS IN THE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DETERMINATION OF ETHANOL AND METHANOL WITH ELECTROCHEMICAL DETECTION

被引:10
作者
TAGLIARO, F
DELEO, D
MARIGO, M
DORIZZI, R
SCHIAVON, G
机构
[1] HOSP LEGNAGO,CLIN CHEM LAB,I-37045 LEGNAGO,ITALY
[2] CNR,IPELP,I-35100 PADUA,ITALY
关键词
D O I
10.1002/bmc.1130040603
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Despite numerous applications both in industry and in analytical chemistry, immobilized enzyme technology has encountered only limited success in modern liquid chromatography. The strict requirements of enzymatic reactors for high performance liquid chromatography (HPLC) (i.e., mechanical resistance, limited void volumes, high contact surface, high binding capacity, stable enzyme‐to‐matrix bond without loss of enzyme activity) are not yet fully met by commercially available products. In our laboratory, the development of post‐column reactors with immobilized alcohol oxidase on‐line with an HPLC/EC system has been undertaken. Three home‐made reactors were produced: in the first alcohol oxidase from Candida boidinii was quasi‐immobilized onto an HPLC‐sized anion exchange support, in the second the enzyme was bound to a silica‐based support via Schiff's base formation, and in the third a covalent linkage to an epoxy‐activated hydroxyalkyl methacrylate material was chosen. Chemical immobilization proved superior to the ionic binding. The importance of limiting the post‐column band spreading due to the reactor void volume, by using HPLC‐sized supports, was confirmed. Copyright © 1990 John Wiley & Sons, Ltd.
引用
收藏
页码:224 / 228
页数:5
相关论文
共 10 条
[1]   ACETALDEHYDE, METHANOL, AND ETHANOL ANALYSIS BY HEADSPACE GAS-CHROMATOGRAPHY [J].
ANTHONY, RM ;
SUTHEIMER, CA ;
SUNSHINE, I .
JOURNAL OF ANALYTICAL TOXICOLOGY, 1980, 4 (01) :43-45
[2]  
Baselt R.C., 1982, DISPOSITION TOXIC DR
[3]  
BELLJEANLEYMARI.M, 1989, ANN BIOL CLIN, V47, P144
[4]   THE USE OF IMMOBILIZED ALCOHOL OXIDASE IN THE CONTINUOUS-FLOW DETERMINATION OF ETHANOL WITH AN OXYGEN-ELECTRODE [J].
GULBERG, EL ;
CHRISTIAN, GD .
ANALYTICA CHIMICA ACTA, 1981, 123 (JAN) :125-133
[5]   INDIVIDUAL AND SIMULTANEOUS DETERMINATION OF ETHANOL AND ACETALDEHYDE IN WINES BY FLOW-INJECTION ANALYSIS AND IMMOBILIZED ENZYMES [J].
LAZARO, F ;
DECASTRO, MDL ;
VALCARCEL, M .
ANALYTICAL CHEMISTRY, 1987, 59 (14) :1859-1863
[6]   SIMPLE APPROACH TO GAS-CHROMATOGRAPHIC MICROANALYSIS OF ALCOHOLS IN BLOOD AND URINE BY A DIRECT-INJECTION TECHNIQUE [J].
MANNO, BR ;
MANNO, JE .
JOURNAL OF ANALYTICAL TOXICOLOGY, 1978, 2 (06) :257-261
[7]  
PRENCIPE L, 1989, BIOCH CLIN, V13, P99
[8]  
SALAMOUN J, 1987, J CHROMATOGR-BIOMED, V420, P197
[9]  
SMITH NB, 1984, CLIN CHEM, V30, P1672
[10]  
WANG J, 1988, ELECTROANALYTICAL TE, P113