Reliability of virtual non-contrast computed tomography angiography: comparing it with the real deal

被引:40
作者
Lehti, Leena [1 ,2 ]
Soderberg, Marcus [3 ]
Hoglund, Peter [1 ]
Nyman, Ulf [4 ]
Gottsater, Anders [1 ,2 ]
Wasselius, Johan [1 ,5 ]
机构
[1] Lund Univ, Dept Clin Sci, Lund, Sweden
[2] Skane Univ Hosp, Vasc Ctr, Malmo, Sweden
[3] Lund Univ, Dept Translat Med, Med Radiat Phys, Malmo, Sweden
[4] Lund Univ, Div Med Radiol, Dept Translat Med, Malmo, Sweden
[5] Skane Univ Hosp, Dept Neuroradiol, Lund, Sweden
关键词
Computed tomography; CT; dual-energy CT; virtual non-contrast; CT angiography; attenuation values;
D O I
10.1177/2058460118790115
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background Computed tomographic angiography (CTA) may require a non-contrast enhanced dataset for the diagnostic workup. By using dual-energy acquisition, it is possible to obtain a virtual non-contrast-enhanced (VNC) dataset, thereby possibly eliminating the non-contrast acquisition and reducing the radiation dose. Purpose To compare image quality of VNC images reconstructed from arterial phase dual-energy CTA to true non-contrast (TNC) images, and to assess whether VNC images were of sufficient quality to replace TNC images. Material and methods Thirty consecutive patients with suspected abdominal aortic aneurysm, aortic dissection, or subacute control after EVAR/TEVAR were examined with dual-energy CT (DECT). The examination protocol included a single-energy TNC, DECT arterial phase (80kV/Sn140kV), and single-energy in venous phase of the aorta. A VNC dataset was obtained from the DE acquisition from arterial phase scans. Mean attenuation and image noise were measured within regions of interest at three levels in the aorta in TNC and VNC images. Comparison of the TNC and VNC images for artefacts was made side-by-side. Subjective evaluation included overall image quality on a 4-grade scale, and quantitative analysis of algorithm-induced artefacts by two experienced readers. Results For all cases, the aortic attenuation was significantly higher at VNC than at TNC. Image noise measured quantitatively was also significantly higher at VNC than at TNC. Subjective image quality was lower for VNC (mean=3.1 for VNC, 3.7=for TNC) but there were no cases rated non-diagnostic. Conclusion VNC images based on arterial phase CTA have significantly higher mean attenuation and higher noise levels compared to TNC.
引用
收藏
页数:6
相关论文
共 19 条
[1]   A software tool for increased efficiency in observer performance studies in radiology [J].
Börjesson, S ;
Håkansson, M ;
Båth, M ;
Kheddache, S ;
Svensson, S ;
Tingberg, A ;
Grahn, A ;
Ruschin, M ;
Hemdal, B ;
Mattsson, S ;
Månsson, LG .
RADIATION PROTECTION DOSIMETRY, 2005, 114 (1-3) :45-52
[2]   Use of baseline factors to predict complications and reinterventions after endovascular repair of abdominal aortic aneurysm [J].
Brown, L. C. ;
Greenhalgh, R. M. ;
Powell, J. T. ;
Thompson, S. G. .
BRITISH JOURNAL OF SURGERY, 2010, 97 (08) :1207-1217
[3]   Virtual Unenhanced Images of the Abdomen With Second-Generation Dual-Source Dual-Energy Computed Tomography Image Quality and Liver Lesion Detection [J].
De Cecco, Carlo Nicola ;
Darnell, Anna ;
Macias, Napoleon ;
Ramon Ayuso, Juan ;
Rodriguez, Sonia ;
Rimola, Jordi ;
Pages, Mario ;
Garcia-Criado, Angeles ;
Rengo, Marco ;
Laghi, Andrea ;
Ayuso, Carmen .
INVESTIGATIVE RADIOLOGY, 2013, 48 (01) :1-9
[4]   Single-Acquisition Dual-Energy Multidetector Computed Tomography: Analysis of Vascular Enhancement and Postprocessing Techniques for Evaluating the Thoracic Aorta [J].
Godoy, Myrna C. B. ;
Naidich, David P. ;
Marchiori, Edson ;
Leidecker, Christianne ;
Schmidt, Bernhard ;
Assadourian, Bernard ;
Vlahos, Ioannis .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2010, 34 (05) :670-677
[5]   Dual-Energy CT in Patients Suspected of Having Renal Masses: Can Virtual Nonenhanced Images Replace True Nonenhanced Images? [J].
Graser, Anno ;
Johnson, Thorsten R. C. ;
Hecht, Elizabeth M. ;
Becker, Christoph R. ;
Leidecker, Christianne ;
Staehler, Michael ;
Stief, Christian G. ;
Hildebrandt, Henriette ;
Godoy, Myrna C. B. ;
Finn, Myra E. ;
Stepansky, Flora ;
Reiser, Maximilian F. ;
Macari, Michael .
RADIOLOGY, 2009, 252 (02) :433-440
[6]   ViewDEX: an efficient and easy-to-use software for observer performance studies [J].
Hakansson, Markus ;
Svensson, Sune ;
Zachrisson, Sara ;
Svalkvist, Angelica ;
Bath, Magnus ;
Mansson, Lars Gunnar .
RADIATION PROTECTION DOSIMETRY, 2010, 139 (1-3) :42-51
[7]   Dual-Energy CT Applications in the Abdomen [J].
Heye, Tobias ;
Nelson, Rendon C. ;
Ho, Lisa M. ;
Marin, Daniele ;
Boll, Daniel T. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 199 (05) :S64-S70
[8]   Technique factors and image quality as functions of patient weight at abdominal CT [J].
Huda, W ;
Scalzetti, EM ;
Levin, G .
RADIOLOGY, 2000, 217 (02) :430-435
[9]   CT effective dose per dose length product using ICRP 103 weighting factors [J].
Huda, Walter ;
Magill, Dennise ;
He, Wenjun .
MEDICAL PHYSICS, 2011, 38 (03) :1261-1265
[10]   Endoleak detection using single-acquisition split-bolus dual-energy computer tomography (DECT) [J].
Javor, D. ;
Wressnegger, A. ;
Unterhumer, S. ;
Kollndorfer, K. ;
Nolz, R. ;
Beitzke, D. ;
Loewe, C. .
EUROPEAN RADIOLOGY, 2017, 27 (04) :1622-1630