MASS AND CHARGE ASSIGNMENT FOR ELECTROSPRAY IONS BY CATION ADDUCTION

被引:27
作者
SENKO, MW [1 ]
BEU, SC [1 ]
MCLAFFERTY, FW [1 ]
机构
[1] CORNELL UNIV,DEPT CHEM,BAKER LAB,ITHACA,NY 14853
关键词
D O I
10.1016/1044-0305(93)80041-V
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The assignment of the mass (m) value from the m/z value for ions with a multiple number of charges (z) in electrospray mass spectra usually utilizes multiple peaks of the same m but different z values, or unit-mass-separated isotopic peaks of the same z value from high resolution spectra. The latter approach is also feasible with much less resolving power using adduct ions of much higher mass separation. The application of this to mixture spectra containing many masses, such as spectra from tandem mass spectrometry (MS/MS) ion dissociation, does not appear to have been pointed out previously. Thus, replacing two protons by one Cu2+ ion increases the mass by 61.5 Da, with this shift providing a mass scale for assignment of m and z from this pair of m/z values. The more common Na+ adduct peaks provide a 22.0 Da separation, of utility for 1000 resolving power only below approximately 10 kDa. Further, collisional dissociation lowers the degree of Cu2+ adduction in the resulting sequence-specific fragment ions much less than that of the corresponding Na+ adducts, making the Cu2+ adducts far more useful for m and z determination in MS/MS studies.
引用
收藏
页码:828 / 830
页数:3
相关论文
共 20 条
[1]   ELECTROSPRAY-IONIZATION MASS-SPECTROMETRY FOR THE DETECTION OF DISCRETE PEPTIDE METAL-ION COMPLEXES INVOLVING MULTIPLE CYSTEINE (SULFUR) LIGANDS [J].
ALLEN, MH ;
HUTCHENS, TW .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1992, 6 (04) :308-312
[2]   FOURIER-TRANSFORM ELECTROSPRAY INSTRUMENTATION FOR TANDEM HIGH-RESOLUTION MASS-SPECTROMETRY OF LARGE MOLECULES [J].
BEU, SC ;
SENKO, MW ;
QUINN, JP ;
WAMPLER, FM ;
MCLAFFERTY, FW .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1993, 4 (07) :557-565
[3]   IMPROVED FOURIER-TRANSFORM ION-CYCLOTRON-RESONANCE MASS-SPECTROMETRY OF LARGE BIOMOLECULES [J].
BEU, SC ;
SENKO, MW ;
QUINN, JP ;
MCLAFFERTY, FW .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1993, 4 (02) :190-192
[4]  
Covey T R, 1988, Rapid Commun Mass Spectrom, V2, P249, DOI 10.1002/rcm.1290021111
[5]   ELECTROSPRAY IONIZATION FOR MASS-SPECTROMETRY OF LARGE BIOMOLECULES [J].
FENN, JB ;
MANN, M ;
MENG, CK ;
WONG, SF ;
WHITEHOUSE, CM .
SCIENCE, 1989, 246 (4926) :64-71
[6]   HIGH-RESOLUTION ELECTROSPRAY MASS-SPECTRA OF LARGE MOLECULES [J].
HENRY, KD ;
QUINN, JP ;
MCLAFFERTY, FW .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1991, 113 (14) :5447-5449
[7]   ELECTROSPRAY IONIZATION WITH FOURIER-TRANSFORM MASS-SPECTROMETRY - CHARGE STATE ASSIGNMENT FROM RESOLVED ISOTOPIC PEAKS [J].
HENRY, KD ;
MCLAFFERTY, FW .
ORGANIC MASS SPECTROMETRY, 1990, 25 (09) :490-492
[8]   PEPTIDE METAL-ION INTERACTIONS IN SOLUTION - DETECTION BY LASER DESORPTION TIME-OF-FLIGHT MASS-SPECTROMETRY AND ELECTROSPRAY IONIZATION MASS-SPECTROMETRY [J].
HUTCHENS, TW ;
NELSON, RW ;
ALLEN, MH ;
LI, CM ;
YIP, TT .
BIOLOGICAL MASS SPECTROMETRY, 1992, 21 (03) :151-159
[9]  
HUTCHENS TW, 1992, RAPID COMMUN MASS SP, V6, P469, DOI 10.1002/rcm.1290060713
[10]   COLLISIONALLY ACTIVATED DISSOCIATION AND TANDEM MASS-SPECTROMETRY OF INTACT HEMOGLOBIN BETA-CHAIN VARIANT PROTEINS WITH ELECTROSPRAY IONIZATION [J].
LIGHTWAHL, KJ ;
LOO, JA ;
EDMONDS, CG ;
SMITH, RD ;
WITKOWSKA, HE ;
SHACKLETON, CHL ;
WU, CSC .
BIOLOGICAL MASS SPECTROMETRY, 1993, 22 (02) :112-120