Comparison of the analytical performance of EDXRF and FAAS techniques in the determination of metal species concentrations using protocol 3050B (USEPA)

被引:8
作者
Bairros da Silva, Paulo Roberto [1 ]
Makara, Cleyton Nascimento [2 ]
Munaro, Ana Paula [2 ]
Schnitzler, Danielle Caroline [2 ]
Wastowski, Arci Dirceu [3 ]
Poleto, Cristiano [4 ]
机构
[1] Univ Sao Paulo, Sao Carlos Sch Engn, Environm Engn Sci, Sao Carlos, Brazil
[2] Fed Technol Univ Parana, Acad Dept Chem & Biol, Curitiba, Parana, Brazil
[3] Univ Fed Santa Maria, Dept Engn & Environm Technol, Frederico Westphalen, Brazil
[4] Univ Fed Rio Grande do Sul, Inst Hydraul Res, Porto Alegre, RS, Brazil
关键词
Sediments; comparison of performance; EDXRF; FAAS;
D O I
10.1080/15715124.2016.1203792
中图分类号
TV21 [水资源调查与水利规划];
学科分类号
081501 ;
摘要
Sediments are active environmental compartments capable of interchanging the chemical species with the water column, degrading their quality and influencing the toxicity of the matrix. The average concentrations of sediment-associated metallic species have been used to evaluate the extent of their contamination. The approaches used have progressed considerably over the last few decades and different instrumental techniques have been employed in quali-quantification of metal compounds associated with sediments. This study aimed to evaluate the accuracy of the technique of Energy Dispersive X-Ray Fluorescence Spectrometry (EDXRF) performed on the equipment Shimadzu (model Rany, Series EDX-720) in the validation process, adopting as reference the technique of Flame Atomic Absorption Spectroscopy (FAAS), appliance GBC (model Avanta) to quantify the species: Zn, Fe, Ni, Cu, Pb and Cr in solution, in chemically available fraction (3050B Protocol-United States Environmental Protection Agency), extracted from sediments of the River Barigui, metropolitan region of Curitiba, southern Brazil. The samples were collected according to the clean techniques protocols. The analytical figures of precision, accuracy and determination limit of the method were evaluated using the two techniques separately and on the same samples. Statistically significant differences were observed between the two methods.
引用
收藏
页码:401 / 406
页数:6
相关论文
共 38 条
[1]   Precision and accuracy of ST-EDXRF performance for As determination comparing with ICP-MS and evaluation of As deviation in the soil media [J].
Akbulut, Songul ;
Cevik, Ugur ;
Van, Aydin Ali ;
De Wael, Karolien ;
Van Grieken, Rene .
CHEMOSPHERE, 2014, 96 :16-22
[2]  
Ana A.N.de A, 2018, GUIA NAC COL PRES AM
[3]  
[Anonymous], BAC HIDR PAR SER HIS
[4]  
ANVISA-Agencia Nacional de Vigilancia Sanitaria, 2003, 899 ANVISA RE MIN SA
[5]  
Araujo R. P. A., 2008, ECOTOXICOLOGIA AQUAT, P293
[6]  
Brito N. M., 2003, Pesticidas - Revista de Ecotoxicologia e Meio Ambiente, V13, P129
[7]   ASSESSING CONTAMINATED SEDIMENTS IN THE CONTEXT OF MULTIPLE STRESSORS [J].
Burton, G. Allen ;
Johnston, Emma L. .
ENVIRONMENTAL TOXICOLOGY AND CHEMISTRY, 2010, 29 (12) :2625-2643
[8]  
Callegari-Jacques S. M., 2008, BIOESTATISTICA PRINC
[9]   Comparative study of elemental content in farmed and wild life Sea Bass and Gilthead Bream from four different sites by FAAS and EDXRF [J].
Custodio, Pedro Jorge ;
Pessanha, Sofia ;
Pereira, Catia ;
Carvalho, Maria Luisa ;
Nunes, Maria Leonor .
FOOD CHEMISTRY, 2011, 124 (01) :367-372
[10]   Paper-based diffusive gradients in thin films technique coupled to energy dispersive X-ray fluorescence spectrometry for the determination of labile Mn, Co, Ni, Cu, Zn and Pb in river water [J].
de Almeida, Eduardo ;
do Nascimento Filho, Virgilio Franco ;
Menegario, Amauri Antonio .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2012, 71-72 :70-74