PULSE OXIMETRY DURING FIBEROPTIC BRONCHOSCOPY IN LOCAL-ANESTHESIA - FREQUENCY OF HYPOXEMIA AND EFFECT OF OXYGEN SUPPLEMENTATION

被引:0
|
作者
MILMAN, N
FAURSCHOU, P
GRODE, G
JORGENSEN, A
机构
关键词
FIBEROPTIC BRONCHOSCOPY; HYPOXEMIA; OXYGEN CATHETER; OXYGEN TREATMENT; PULSE OXIMETRY;
D O I
暂无
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
The indication for oxygen supplementation during diagnostic fibreoptic bronchoscopy (FOB) in local anaesthesia was evaluated by means of pulse oximetry in 160 patients (108 men, 52 women), median age 62 years. The patients were allocated at random into four groups of each 40 persons, which were comparable concerning pulmonary function and the dose of benzodiazepine used for premedication. The oxygen saturation of the haemoglobin (SpO(2)) in the tip of the index finger and the pulse rate were continuously recorded. Group 1 was examined without O-2 supplement. Group 2a received O-2 2 litres/min through a pharyngeal catheter. Group 3 received O-2 3 litres/min through a pharyngeal catheter. SpO(2) mean values during FOB were 92 +/- (SD) 3% in group 1 and 96 +/- 2% in groups 2a, 2b and 3 (p<0.001). SpO(2) <85%, occurred with a frequency of 35% in group 1, 2.5% in group 2a, 0% in group 2b, and 2.5% in group 3. Tachycardia and bradycardia during FOB occurred with a frequency of 20% in group 1, 25% in group 2a, 18% in group 2b, and 10% in group 3. Pulse oximetry increases the safety of FOB, and is recommended for routine use. During FOB, oxygen supplement 2-3 litres/min should be administered to all patients, preferably through a pharyngeal catheter, as a preventive measure against hypoxaemia.
引用
收藏
页码:342 / 347
页数:6
相关论文
共 4 条
  • [1] Esophageal pulse oximetry is more accurate and detects hypoxemia earlier than conventional pulse oximetry during general anesthesia
    Guo Chen
    Zhaoqiong Zhu
    Jin Liu
    Wei Wei
    Frontiers of Medicine, 2012, 6 (4) : 406 - 410
  • [2] Overestimation of Oxygen Saturation Measured by Pulse Oximetry in Hypoxemia. Part 1: Effect of Optical Pathlengths-Ratio Increase
    Elron, Eyal
    Bromiker, Ruben
    Gleisner, Ori
    Yosef-Hai, Ohad
    Goldberg, Ori
    Nitzan, Itamar
    Nitzan, Meir
    SENSORS, 2023, 23 (03)
  • [3] Does pulse oximetry accurately monitor a patient's ventilation during sedated endoscopy under oxygen supplementation?
    Arakawa, Hiroshi
    Kaise, Mitsuru
    Sumiyama, Kazuki
    Saito, Shoichi
    Suzuki, Takeshi
    Tajiri, Hisao
    SINGAPORE MEDICAL JOURNAL, 2013, 54 (04) : 212 - 215
  • [4] The effect of maternal oxygen administration on fetal pulse oximetry during labor in fetuses with nonreassuring fetal heart rate patterns
    Haydon, Michael L.
    Gorenberg, David M.
    Nageotte, Michael P.
    Ghamsary, Mark
    Rumney, Pamela I.
    Patillo, Carol
    Garite, Thomas J.
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2006, 195 (03) : 735 - 738