Lipofibromatous hamartoma of the median nerve: 3T MRI evaluation by constrained spherical deconvolution analysis

被引:0
|
作者
Arrigo, Alessandro [1 ]
Gaeta, Michele [1 ]
Calamuneri, Alessandro [1 ]
Mormina, Enricomaria [1 ]
Marino, Silvia [2 ]
d'Alcontres, Francesco Stagno [3 ]
Longo, Marcello [1 ]
Granata, Francesca [1 ]
机构
[1] Univ Messina, Dept Biomed Sci & Morphol & Funct Imaging, Via Consolare Valeria 1, I-98125 Messina, Italy
[2] IRCCS Ctr Neurolesi Bonino Pulejo, Messina, ME, Italy
[3] Univ Messina, Dept Human Pathol Adults Children & Adolescents, Messina, Italy
关键词
Median nerve; hamartoma; MRI; tractography; constrained spherical deconvolution;
D O I
10.1177/1971400917709622
中图分类号
R445 [影像诊断学];
学科分类号
100207 ;
摘要
In this study we described a case of lipofibromatous hamartoma involving the median nerve. We adopted diffusion tensor imaging and constrained spherical deconvolution-based tractography to reconstruct the affected median nerve. Moreover, we extracted diffusion-based parameters reflecting axonal integrity loss of median nerve fibres. Our data showed that constrained spherical deconvolution-based tractography outperformed the diffusion tensor imaging-based method, allowing the detection of the entire median nerve, including its branches, thus offering a robust method to investigate the involvement of the median nerve in pathological conditions. All clinical and technical implications are extensively described.
引用
收藏
页码:445 / 448
页数:4
相关论文
共 38 条
  • [21] Development of a Transfer-Function Measurement Procedure for the Evaluation of MRI-Conditional Medical Devices at 3T
    Attaran, Ali
    Handler, William B.
    Wawrzyn, Krzysztof
    Chronik, Blaine A.
    2018 IEEE CANADIAN CONFERENCE ON ELECTRICAL & COMPUTER ENGINEERING (CCECE), 2018,
  • [22] MRI of the female pelvis at 3T compared to 1.5T: Evaluation on high-resolution T2-weighted and HASTE images
    Kataoka, Masako
    Kido, Aki
    Koyama, Takashi
    Isoda, Hiroyoshi
    Umeoka, Shigeaki
    Tamai, Ken
    Nakamoto, Yuji
    Maetani, Yoji
    Morisawa, Nobuko
    Saga, Tsuneo
    Togashi, Kaori
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2007, 25 (03) : 527 - 534
  • [23] Evaluation of the RF depositions at 3T in routine clinical scans with respect to the SAR safety to improve efficiency of MRI utilization
    Li, Ruixin
    Chen, Xinlian
    Liao, Yupeng
    Xin, Sherman Xuegang
    BIOMEDICAL ENGINEERING-BIOMEDIZINISCHE TECHNIK, 2025, 70 (01): : 49 - 59
  • [24] Connectivity analysis of anterior nuclei of the thalamus in diffusion- MRI using constrained spherical deconvolution (CSD), multi-shell multi-tissue CSD and probabilistic DTI for ANT-DBS in epilepsy
    Ozdemir, Ruhunur
    Lehtimaki, Kai
    Peltola, Jukka
    Eskola, Hannu
    MEDICAL IMAGING 2020: BIOMEDICAL APPLICATIONS IN MOLECULAR, STRUCTURAL, AND FUNCTIONAL IMAGING, 2021, 11317
  • [25] Is 3T MR nerve-bone fusion imaging a viable alternative to MRI-CBCT to identify the relationship between the inferior alveolar nerve and mandibular third molar
    Huang, Hao
    Yan, Yalan
    Jiang, Dongmei
    Zhao, Xiance
    Cao, Dairong
    She, Dejun
    CLINICAL ORAL INVESTIGATIONS, 2024, 28 (05)
  • [26] Design and evaluation of a 1H/31P double-resonant helmet coil for 3T MRI of the brain
    Hong, Suk-Min
    Choi, Chang-Hoon
    Shah, N. Jon
    Felder, Joerg
    PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (03)
  • [27] Feasibility and evaluation of dual-source transmit 3D imaging of the orbits: Comparison to high-resolution conventional MRI at 3T
    Seeger, Achim
    Schulze, Maximilian
    Schuettauf, Frank
    Klose, Uwe
    Ernemann, Ulrike
    Hauser, Till-Karsten
    EUROPEAN JOURNAL OF RADIOLOGY, 2015, 84 (06) : 1150 - 1158
  • [28] Quantitative T2☆ Relaxation Time Analysis of Articular Cartilage of the Tibiotalar Joint in Professional Football Players and Healthy Volunteers at 3T MRI
    Behzadi, Cyrus
    Maas, Kai-Jonathan
    Welsch, Goetz
    Kaul, Michael
    Schoen, Gerhard
    Laqmani, Azien
    Adam, Gerhard
    Regier, Marc
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2018, 47 (02) : 372 - 379
  • [29] Role of 3T multiparametric-MRI with BOLD hypoxia imaging for diagnosis and post therapy response evaluation of postoperative recurrent cervical cancers
    Mahajan, Abhishek
    Engineer, Reena
    Chopra, Supriya
    Mahanshetty, Umesh
    Juvekar, S. L.
    Shrivastava, S. K.
    Desekar, Naresh
    Thakura, M. H.
    EUROPEAN JOURNAL OF RADIOLOGY OPEN, 2016, 3 : 22 - 30
  • [30] Dynamic contrast-enhanced case-control analysis in 3T MRI of prostate cancer can help to characterize tumor aggressiveness
    Sanz-Requena, Roberto
    Marti-Bonmati, Luis
    Perez-Martinez, Rosario
    Garcia-Marti, Gracian
    EUROPEAN JOURNAL OF RADIOLOGY, 2016, 85 (11) : 2119 - 2126