THE LEAD LIQUID ARGON SAMPLING CALORIMETER OF THE SLD DETECTOR

被引:31
|
作者
AXEN, D
BOUGEROLLE, S
SOBIE, R
EIGEN, G
DEJONGH, F
HITLIN, D
KELSEY, M
KLEIN, M
MINCER, A
WISNIEWSKI, W
WOLF, R
ARROYO, C
AU, Y
BALTAY, C
BOLTON, T
BAZARKO, A
CAMILLERI, L
HYATT, E
MANLY, S
RABINOWITZ, S
ROWSON, PC
SELIGMAN, S
SHAEVITZ, MH
SMITH, S
STEINER, RV
ABT, I
ALZOFON, D
ARNETT, D
BARRERA, F
BELL, R
BES, SC
BOGART, J
BREIDENBACH, M
CANDIA, A
CLAUS, R
CUTLER, H
DAVIS, R
DUBOIS, R
FOSS, M
FOX, J
FOX, M
GIOUMOUSIS, A
GREBENYUK, A
HALLER, G
HAMILTON, V
HODGSON, J
HUFFER, M
JUNK, T
KIM, P
LABS, J
机构
[1] UNIV BRITISH COLUMBIA,VANCOUVER V6T 2A6,BC,CANADA
[2] CALTECH,PASADENA,CA 91125
[3] COLUMBIA UNIV,NEVIS LAB,IRVINGTON,NY 10533
[4] STANFORD LINEAR ACCELERATOR CTR,STANFORD,CA 94309
[5] UNIV TENNESSEE,KNOXVILLE,TN 37996
[6] TRIUMF,VANCOUVER V6T 2A3,BC,CANADA
[7] UNIV VICTORIA,VICTORIA V8W 2Y2,BC,CANADA
[8] UNIV WASHINGTON,SEATTLE,WA 98195
关键词
D O I
10.1016/0168-9002(93)90664-4
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The lead-liquid argon sampling calorimeter of the SLD detector is one of the largest detectors employing cryogenic liquids now in operation. This paper details the design and performance considerations, the mechanical and cryogenic systems, the absorber design and tower segmentation, the data acquisition electronics, and the control systems of the detector. The initial operational performance of the device is discussed. Detailed resolution studies will be presented in a later paper.
引用
收藏
页码:472 / 494
页数:23
相关论文
共 50 条
  • [1] Lead-liquid argon sampling calorimeter of the SLD detector
    Axen, D.
    Bougerolle, S.
    Sobie, R.
    Eigen, G.
    De Jongh, F.
    Hitlin, D.
    Kelsey, M.
    Klein, M.
    Mincer, A.
    Wisniewski, W.
    Wolf, R.
    Arroyo, C.
    Au, Y.
    Baltay, C.
    Bolton, T.
    Bazarko, A.
    Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1993, A328 (03) : 472 - 494
  • [2] A CRYOGENIC MONITOR SYSTEM FOR THE LIQUID ARGON CALORIMETER IN THE SLD DETECTOR
    FOX, MJ
    FOX, JD
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1989, 36 (01) : 751 - 755
  • [3] SLD LIQUID ARGON CALORIMETER PROTOTYPE TEST RESULTS.
    Dubois, R.
    Hodges, T.
    Langstaff, R.
    Mason, G.R.
    Robertson, L.P.
    Eigen, G.
    Hitlin, D.
    Schindler, R.H.
    Warfield, K.
    Zhu, Y.
    Au, Y.
    Baltay, C.
    Manly, S.
    Shaevitz, M.H.
    Smith, S.R.
    IEEE Transactions on Nuclear Science, 1985, NS-33 (01)
  • [4] THE ANALOG PROCESSING SYSTEM FOR THE LIQUID ARGON CALORIMETER FOR SLD AT SLAC
    HALLER, GM
    NELSON, D
    FREYTAG, DR
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1987, 34 (01) : 170 - 174
  • [5] SLD LIQUID ARGON CALORIMETER PROTOTYPE TEST-RESULTS
    DUBOIS, R
    HODGES, T
    LANGSTAFF, R
    MASON, GR
    ROBERTSON, LP
    EIGEN, G
    HITLIN, D
    SCHINDLER, RH
    WARFIELD, K
    ZHU, Y
    AU, Y
    BALTAY, C
    MANLY, S
    SHAEVITZ, MH
    SMITH, SR
    SLEEMAN, J
    BREIDENBACH, M
    NELSON, D
    NORDBY, M
    LYNCH, H
    ROTHENBERG, AF
    SKARPAAS, K
    WOLF, G
    BRAU, J
    BUGG, W
    WEIDEMANN, A
    LUDGATE, GA
    ORAM, CJ
    COOK, V
    DAVISSON, R
    DUNCAN, AL
    FORBUSH, D
    GUY, A
    MOCKETT, PM
    VELLA, E
    JOHNSON, J
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1986, 33 (01) : 194 - 196
  • [6] ANALOG PROCESSING SYSTEM FOR THE LIQUID ARGON CALORIMETER FOR SLD AT SLAC.
    Haller, G.M.
    Nelson, D.
    Freytag, D.R.
    1600, (NS-34):
  • [7] PARTICLE IDENTIFICATION WITH THE LIQUID ARGON CALORIMETER OF THE CELLO DETECTOR
    AHME, J
    FEINDT, M
    HARJES, J
    PETERS, JH
    HELVETICA PHYSICA ACTA, 1987, 60 (5-6): : 683 - 683
  • [8] THE LIQUID ARGON CALORIMETER SYSTEM FOR THE SLC LARGE DETECTOR
    HALLER, GM
    FOX, JD
    SMITH, SR
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1989, 36 (01) : 675 - 679
  • [9] TEST OF A LIQUID ARGON CALORIMETER WITH VERY THIN SAMPLING
    CERRI, C
    SERGIAMPIETRI, F
    NUCLEAR INSTRUMENTS & METHODS, 1977, 141 (02): : 207 - 218
  • [10] PI/E DISCRIMINATION WITH A LEAD LIQUID ARGON CALORIMETER
    MICKE, U
    TRINES, D
    WALLRAFF, W
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1984, 221 (03): : 495 - 502