Estimation of intra-operator variability in perfusion parameter measurements using DCE-US

被引:40
作者
Gauthier, Marianne [1 ]
Leguerney, Ingrid [1 ]
Thalmensi, Jessie [1 ]
Chebil, Mohamed [2 ]
Parisot, Sarah [1 ]
Peronneau, Pierre [1 ]
Roche, Alain [1 ]
Lassau, Nathalie [1 ,2 ]
机构
[1] Paris Sud 11 Univ, CNRS, Gustave Roussy Inst, UMR 8081,IR4M, F-94805 Villejuif, France
[2] Gustave Roussy Inst, Dept Imaging, Ultrasonog Unit, F-94805 Villejuif, France
来源
WORLD JOURNAL OF RADIOLOGY | 2011年 / 3卷 / 03期
关键词
Dynamic contrast-enhanced ultrasonography; Intra-operator variability; Functional imaging; Semi-quantitative perfusion parameters; Linear raw data; Quantification;
D O I
10.4329/wjr.v3.i3.70
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
AIM: To investigate intra-operator variability of semi-quantitative perfusion parameters using dynamic contrast-enhanced ultrasonography (DCE-US), following bolus injections of SonoVue (R). METHODS: The in vitro experiments were conducted using three in-house sets up based on pumping a fluid through a phantom placed in a water tank. In the in vivo experiments, B16F10 melanoma cells were xenografted to five nude mice. Both in vitro and in vivo, images were acquired following bolus injections of the ultrasound contrast agent SonoVue (R) (Bracco, Milan, Italy) and using a Toshiba Aplio (R) ultrasound scanner connected to a 2.9-5.8 MHz linear transducer (PZT, PLT 604AT probe) (Toshiba, Japan) allowing harmonic imaging ("Vascular Recognition Imaging") involving linear raw data. A mathematical model based on the dye-dilution theory was developed by the Gustave Roussy Institute, Villejuif, France and used to evaluate seven perfusion parameters from time-intensity curves. Intra-operator variability analyses were based on determining perfusion parameter coefficients of variation (CV). RESULTS: In vitro, different volumes of SonoVue (R) were tested with the three phantoms: intra-operator variability was found to range from 2.33% to 23.72%. In vivo, experiments were performed on tumor tissues and perfusion parameters exhibited values ranging from 1.48% to 29.97%. In addition, the area under the curve (AUC) and the area under the wash-out (AUWO) were two of the parameters of great interest since throughout in vitro and in vivo experiments their variability was lower than 15.79%. CONCLUSION: AUC and AUWO appear to be the most reliable parameters for assessing tumor perfusion using DCE-US as they exhibited the lowest CV values. (C) 2011 Baishideng. All rights reserved.
引用
收藏
页码:70 / 81
页数:12
相关论文
共 57 条
  • [1] Experimental investigation and theoretical modelling of the nonlinear acoustical behaviour of a liver tissue and comparison with a tissue mimicking hydrogel
    Casciaro, Sergio
    Demitri, Christian
    Conversano, Francesco
    Casciaro, Ernesto
    Distante, Alessandro
    [J]. JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2008, 19 (02) : 899 - 906
  • [2] Experimental investigations of nonlinearities and destruction mechanisms of an experimental phospholipid-based ultrasound contrast agent
    Casciaro, Sergio
    Errico, Rosa Palmizio
    Conversano, Francesco
    Demitri, Christian
    Distante, Alessandro
    [J]. INVESTIGATIVE RADIOLOGY, 2007, 42 (02) : 95 - 104
  • [3] Full experimental modelling of a liver tissue mimicking phantom for medical ultrasound studies employing different hydrogels
    Casciaro, Sergio
    Conversano, Francesco
    Musio, Stefano
    Casciaro, Ernesto
    Demitri, Christian
    Sannino, Alessandro
    [J]. JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2009, 20 (04) : 983 - 989
  • [4] Cenic A, 1999, AM J NEURORADIOL, V20, P63
  • [5] Quantification of flow rates using harmonic grey-scale imaging and an ultrasound contrast agent:: an in vitro and in vivo study
    Claassen, L
    Seidel, G
    Algermissen, C
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2001, 27 (01) : 83 - 88
  • [6] Infusion versus bolus of an ultrasound contrast agent - In vivo dose-response measurements of BR1
    Correas, JM
    Burns, PN
    Lai, XM
    Qi, XL
    [J]. INVESTIGATIVE RADIOLOGY, 2000, 35 (01) : 72 - 79
  • [7] de Marco G., 2004, Medecine Nucleaire, V28, P35
  • [8] Contrast-enhanced ultrasound for molecular imaging of angiogenesis
    Eisenbrey, J. R.
    Forsberg, F.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2010, 37 : S138 - S146
  • [9] New response evaluation criteria in solid tumours: Revised RECIST guideline (version 1.1)
    Eisenhauer, E. A.
    Therasse, P.
    Bogaerts, J.
    Schwartz, L. H.
    Sargent, D.
    Ford, R.
    Dancey, J.
    Arbuck, S.
    Gwyther, S.
    Mooney, M.
    Rubinstein, L.
    Shankar, L.
    Dodd, L.
    Kaplan, R.
    Lacombe, D.
    Verweij, J.
    [J]. EUROPEAN JOURNAL OF CANCER, 2009, 45 (02) : 228 - 247
  • [10] Magnetic resonance imaging measurements of the response of murine and human tumors to the vascular-targeting agent ZD6126
    Evelhoch, JL
    LoRusso, PM
    He, ZQ
    DelProposto, Z
    Polin, L
    Corbett, TH
    Langmuir, P
    Wheeler, C
    Stone, A
    Leadbetter, J
    Ryan, AJ
    Blakey, DC
    Waterton, JC
    [J]. CLINICAL CANCER RESEARCH, 2004, 10 (11) : 3650 - 3657