MEASUREMENT POSSIBILITIES USING AN ELECTRONIC PORTAL IMAGING DEVICE

被引:63
|
作者
KIRBY, MC
WILLIAMS, PC
机构
[1] North Western Medical Physics Department, Christie Hospital, Manchester
关键词
PORTAL IMAGING; EXIT DOSIMETRY; QUALITY CONTROL; MULTILEAF COLLIMATOR;
D O I
10.1016/0167-8140(93)90253-5
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
A vital role in the quality control of radiotherapy is the use of portal imaging for verifying field size, shape, orientation and patient set-up. Coincidence of treated volume and target volume is imperative. Electronic portal imaging devices are effective at providing this verification. However, these devices are versatile enough to be used in other ways pertinent to the delivery of high quality, high precision radiotherapy. This paper examines two such ways: in assessing the reproducibility of a multileaf collimator system, and in determining exit doses in vivo. Configured as a dosemeter, the system shows a linear response with good dynamic ranger Its high spatial resolution was used to show that leaf positioning was reproducible to within 0.5 mm for all tested gantry and collimator angles. Our preliminary results from this exit dosimetry technique demonstrate that, under specific conditions, doses can be determined to within 2.5% of that measured using silicon diodes or ion chambers.
引用
收藏
页码:237 / 243
页数:7
相关论文
共 50 条
  • [41] Anatomy changes in radiotherapy detected using portal imaging
    McDermott, Leah N.
    Wendling, Markus
    Sonke, Jan-Jakob
    van Herk, Marcel
    Mijnheer, Ben J.
    RADIOTHERAPY AND ONCOLOGY, 2006, 79 (02) : 211 - 217
  • [42] Set-up verification using portal imaging; review of current clinical practice
    Hurkmans, CW
    Remeijer, P
    Lebesque, JV
    Mijnheer, BJ
    RADIOTHERAPY AND ONCOLOGY, 2001, 58 (02) : 105 - 120
  • [43] CLINICAL IMPLEMENTATION OF AN OBJECTIVE COMPUTER-AIDED PROTOCOL FOR INTERVENTION IN INTRA-TREATMENT CORRECTION USING ELECTRONIC PORTAL IMAGING
    VANDENHEUVEL, F
    DENEVE, W
    VERELLEN, D
    COGHE, M
    COEN, V
    STORME, G
    RADIOTHERAPY AND ONCOLOGY, 1995, 35 (03) : 232 - 239
  • [44] Use of skin markers and electronic portal imaging to improve verification of tangential breast irradiation
    van der Salm, Anke
    Strijbos, Jennifer
    Dijcks, Colette
    Murrer, Lars
    Borger, Jacques
    Boersma, Liesbeth
    RADIOTHERAPY AND ONCOLOGY, 2009, 90 (01) : 106 - 109
  • [45] Comparison of Electronic Portal Imaging and Cone Beam Computed Tomography for Position Verification in Children
    Zaghloul, M. S.
    Mousa, A. G.
    Eldebawy, E.
    Attalla, E.
    Shafik, H.
    Ezzat, S.
    CLINICAL ONCOLOGY, 2010, 22 (10) : 850 - 861
  • [46] Theoretical analysis and experimental evaluation of a CsI(Tl) based electronic portal imaging system
    Sawant, A
    Zeman, H
    Samant, S
    Lovhoiden, G
    Weinberg, B
    DiBianca, F
    MEDICAL PHYSICS, 2002, 29 (06) : 1042 - 1053
  • [47] Patient-specific quality control for intensity-modulated radiation therapy and volumetric-modulated arc therapy using electronic portal imaging device and two-dimensional ion chamber array
    Kausar, Abu
    Mani, Karthick R.
    Azhari, Hasin A.
    Zakaria, Golam A.
    JOURNAL OF RADIOTHERAPY IN PRACTICE, 2019, 18 (01) : 26 - 31
  • [48] Electronic portal imaging with on-line correction of setup error in thoracic irradiation: Clinical evaluation
    Van de Steene, J
    Van den Heuvel, F
    Bel, A
    Verellen, D
    De Mey, J
    Noppen, M
    De Beukeleer, M
    Storme, G
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1998, 40 (04): : 967 - 976
  • [49] Performance of electronic portal imaging devices (EPIDs) used in radiotherapy:: Image quality and dose measurements
    Cremers, F
    Frenzel, T
    Kausch, C
    Albers, D
    Schönborn, T
    Schmidt, R
    MEDICAL PHYSICS, 2004, 31 (05) : 985 - 996
  • [50] Clinical use of electronic portal imaging: Report of AAPM radiation therapy committee Task Group 58
    Herman, MG
    Balter, JM
    Jaffray, DA
    McGee, KP
    Munro, P
    Shalev, S
    Van Herk, M
    Wong, JW
    MEDICAL PHYSICS, 2001, 28 (05) : 712 - 737