MEASUREMENT POSSIBILITIES USING AN ELECTRONIC PORTAL IMAGING DEVICE

被引:63
|
作者
KIRBY, MC
WILLIAMS, PC
机构
[1] North Western Medical Physics Department, Christie Hospital, Manchester
关键词
PORTAL IMAGING; EXIT DOSIMETRY; QUALITY CONTROL; MULTILEAF COLLIMATOR;
D O I
10.1016/0167-8140(93)90253-5
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
A vital role in the quality control of radiotherapy is the use of portal imaging for verifying field size, shape, orientation and patient set-up. Coincidence of treated volume and target volume is imperative. Electronic portal imaging devices are effective at providing this verification. However, these devices are versatile enough to be used in other ways pertinent to the delivery of high quality, high precision radiotherapy. This paper examines two such ways: in assessing the reproducibility of a multileaf collimator system, and in determining exit doses in vivo. Configured as a dosemeter, the system shows a linear response with good dynamic ranger Its high spatial resolution was used to show that leaf positioning was reproducible to within 0.5 mm for all tested gantry and collimator angles. Our preliminary results from this exit dosimetry technique demonstrate that, under specific conditions, doses can be determined to within 2.5% of that measured using silicon diodes or ion chambers.
引用
收藏
页码:237 / 243
页数:7
相关论文
共 50 条
  • [31] Use of electronic portal imaging devices for electron treatment verification
    T. Kairn
    T. Aland
    S. B. Crowe
    J. V. Trapp
    Australasian Physical & Engineering Sciences in Medicine, 2016, 39 : 199 - 209
  • [32] A DIAGNOSTIC-QUALITY ELECTRONIC PORTAL IMAGING-SYSTEM
    SEPHTON, R
    HAGEKYRIAKOU, J
    RADIOTHERAPY AND ONCOLOGY, 1995, 35 (03) : 240 - 247
  • [33] Use of electronic portal imaging devices for electron treatment verification
    Kairn, T.
    Aland, T.
    Crowe, S. B.
    Trapp, J. V.
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2016, 39 (01) : 199 - 209
  • [34] Patient-specific daily pretreatment setup protocol using electronic portal imaging for radiation therapy
    Wittmer, Michael H.
    Pisansky, Thomas M.
    Kruse, Jon J.
    Herman, Michael G.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2005, 6 (04): : 1 - 13
  • [35] Determination of optimum planning target volume margins for various tumor sites using electronic portal imaging
    Andrieu, MN
    Dirican, B
    Ozturk, AY
    Hicsonmez, A
    Kurtman, C
    EXPERIMENTAL ONCOLOGY, 2004, 26 (03) : 236 - 239
  • [36] Electronic portal imaging with an avalanche-multiplication-based video camera
    Pang, G
    Rowlands, JA
    MEDICAL PHYSICS, 2000, 27 (04) : 676 - 684
  • [37] Feasibility study using a Ni-Ti stent and electronic portal imaging to localize the prostate during radiotherapy
    Carl, J
    Lund, B
    Larsen, EH
    Nielsen, J
    RADIOTHERAPY AND ONCOLOGY, 2006, 78 (02) : 199 - 206
  • [38] Electronic portal imaging based on Cerenkov radiation: A new approach and its feasibility
    Mei, X.
    Rowlands, J. A.
    Pang, G.
    MEDICAL PHYSICS, 2006, 33 (11) : 4258 - 4270
  • [39] Quality control of VMAT synchronization using portal imaging
    Bedford, James L.
    Chajecka-Szczygielska, Honorata
    Thomas, Michael D. R.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2015, 16 (01): : 284 - 297
  • [40] PORTAL IMAGING FOR THE VERIFICATION OF BREAST TREATMENTS
    KIRBY, MC
    WILLIAMS, PC
    RADIOTHERAPY AND ONCOLOGY, 1991, 22 (04) : 314 - 316