MEASUREMENT POSSIBILITIES USING AN ELECTRONIC PORTAL IMAGING DEVICE

被引:63
|
作者
KIRBY, MC
WILLIAMS, PC
机构
[1] North Western Medical Physics Department, Christie Hospital, Manchester
关键词
PORTAL IMAGING; EXIT DOSIMETRY; QUALITY CONTROL; MULTILEAF COLLIMATOR;
D O I
10.1016/0167-8140(93)90253-5
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
A vital role in the quality control of radiotherapy is the use of portal imaging for verifying field size, shape, orientation and patient set-up. Coincidence of treated volume and target volume is imperative. Electronic portal imaging devices are effective at providing this verification. However, these devices are versatile enough to be used in other ways pertinent to the delivery of high quality, high precision radiotherapy. This paper examines two such ways: in assessing the reproducibility of a multileaf collimator system, and in determining exit doses in vivo. Configured as a dosemeter, the system shows a linear response with good dynamic ranger Its high spatial resolution was used to show that leaf positioning was reproducible to within 0.5 mm for all tested gantry and collimator angles. Our preliminary results from this exit dosimetry technique demonstrate that, under specific conditions, doses can be determined to within 2.5% of that measured using silicon diodes or ion chambers.
引用
收藏
页码:237 / 243
页数:7
相关论文
共 50 条
  • [21] 1ST CLINICAL-EXPERIENCE WITH A NEWLY DEVELOPED ELECTRONIC PORTAL IMAGING DEVICE
    MEERTENS, H
    VANHERK, M
    BIJHOLD, J
    BARTELINK, H
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1990, 18 (05): : 1173 - 1181
  • [22] The use of an electronic portal imaging system to measure portal dose and portal dose profiles
    Parsaei, H
    El-Khatib, E
    Rajapakshe, R
    MEDICAL PHYSICS, 1998, 25 (10) : 1903 - 1909
  • [23] A REVIEW OF ELECTRONIC PORTAL IMAGING DEVICES (EPIDS)
    BOYER, AL
    ANTONUK, L
    FENSTER, A
    VANHERK, M
    MEERTENS, H
    MUNRO, P
    REINSTEIN, LE
    WONG, J
    MEDICAL PHYSICS, 1992, 19 (01) : 1 - 16
  • [24] Study of a prototype high quantum efficiency thick scintillation crystal video-electronic portal imaging device
    Samant, Sanjiv S.
    Gopal, Arun
    MEDICAL PHYSICS, 2006, 33 (08) : 2783 - 2791
  • [25] AN OBJECTIVE METHOD FOR EVALUATING ELECTRONIC PORTAL IMAGING DEVICES
    DONG, L
    BOYER, AL
    MEDICAL PHYSICS, 1994, 21 (06) : 755 - 760
  • [26] Dose response characteristics of a novel CCD camera-based electronic portal imaging device comparison with OCTAVIUS detector
    Anvari, Akbar
    Aghamiri, Seyed Mahmoud Reza
    Mahdavi, Seyed Rabie
    Alaei, Parham
    JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2015, 11 (04) : 765 - 769
  • [27] A novel water-equivalent electronic portal imaging device for radiotherapy with improved detective quantum efficiency: Proof of concept
    Blake, Samuel J.
    Cheng, Zhangkai
    Atakaramians, Shaghik
    Meikle, Steven
    Lu, Minghui
    Vial, Philip
    Kuncic, Zdenka
    2017 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2017,
  • [28] TIME TREND OF PATIENT SETUP DEVIATIONS DURING PELVIC IRRADIATION USING ELECTRONIC PORTAL IMAGING
    ELGAYED, AAH
    BEL, A
    VIJLBRIEF, R
    BARTELINK, H
    LEBESQUE, JV
    RADIOTHERAPY AND ONCOLOGY, 1993, 26 (02) : 162 - 171
  • [29] Measurement of quantum noise in fluoroscopic systems for portal imaging
    Mah, DW
    Rowlands, JA
    Rawlinson, JA
    MEDICAL PHYSICS, 1996, 23 (02) : 231 - 238
  • [30] Direct measurement and analytical modeling of scatter in portal imaging
    Spies, L
    Evans, PM
    Partridge, M
    Hansen, VN
    Bortfeld, T