MEASUREMENT POSSIBILITIES USING AN ELECTRONIC PORTAL IMAGING DEVICE

被引:63
|
作者
KIRBY, MC
WILLIAMS, PC
机构
[1] North Western Medical Physics Department, Christie Hospital, Manchester
关键词
PORTAL IMAGING; EXIT DOSIMETRY; QUALITY CONTROL; MULTILEAF COLLIMATOR;
D O I
10.1016/0167-8140(93)90253-5
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
A vital role in the quality control of radiotherapy is the use of portal imaging for verifying field size, shape, orientation and patient set-up. Coincidence of treated volume and target volume is imperative. Electronic portal imaging devices are effective at providing this verification. However, these devices are versatile enough to be used in other ways pertinent to the delivery of high quality, high precision radiotherapy. This paper examines two such ways: in assessing the reproducibility of a multileaf collimator system, and in determining exit doses in vivo. Configured as a dosemeter, the system shows a linear response with good dynamic ranger Its high spatial resolution was used to show that leaf positioning was reproducible to within 0.5 mm for all tested gantry and collimator angles. Our preliminary results from this exit dosimetry technique demonstrate that, under specific conditions, doses can be determined to within 2.5% of that measured using silicon diodes or ion chambers.
引用
收藏
页码:237 / 243
页数:7
相关论文
共 50 条
  • [1] PORTAL DOSE MEASUREMENT IN RADIOTHERAPY USING AN ELECTRONIC PORTAL IMAGING DEVICE (EPID)
    HEIJMEN, BJM
    PASMA, KL
    KROONWIJK, M
    ALTHOF, VGM
    DEBOER, JCJ
    VISSER, AG
    HUIZENGA, H
    PHYSICS IN MEDICINE AND BIOLOGY, 1995, 40 (11): : 1943 - 1955
  • [2] Radiological thickness measurement using a liquid ionization chamber electronic portal imaging device
    Evans, PM
    Donovan, EM
    Partridge, M
    Bidmead, AM
    Garton, A
    Mubata, C
    PHYSICS IN MEDICINE AND BIOLOGY, 1999, 44 (06): : N89 - N97
  • [3] Accurate measurement of the dynamic response of a scanning electronic portal imaging device
    Ploeger, LS
    Smitsmans, MHP
    Gilhuijs, KGA
    van Herk, M
    MEDICAL PHYSICS, 2001, 28 (03) : 310 - 316
  • [4] Verification and Measurement of the Tongue and Groove Effect in an Electronic Portal Imaging Device
    Saez Beltran, J.
    Alba, L.
    Clara, B.
    Vieillevigne, L.
    Khamphan, C.
    Hernandez, V.
    RADIOTHERAPY AND ONCOLOGY, 2019, 133 : S970 - S971
  • [5] Radiation isocenter verification using the electronic portal imaging device
    Merino, J. A.
    Portas, B. C.
    Rosa, P.
    Chapel, M. L.
    Fernandez, S.
    Medina, E. G.
    Ramos, S.
    Vazquez, P.
    Husillos, F.
    RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S165 - S166
  • [6] Small field measurements using electronic portal imaging device
    Sait, A. Aziz
    Yoganathan, S. A.
    Jones, Glenn W.
    Patel, Tusar
    Rastogi, Nikhil
    Pandey, S. P.
    Mani, Sunil
    Boopathy, Raghavendiran
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2024, 10 (05):
  • [7] LINAC Quality Assurance and Calibration Using Electronic Portal Imaging Device
    Ramirez, H.
    Yan, D.
    Zhang, T.
    MEDICAL PHYSICS, 2009, 36 (06)
  • [8] Verification of compensator thicknesses using a fluoroscopic electronic portal imaging device
    Pasma, KL
    Kroonwijk, M
    van Dieren, EB
    Visser, AG
    Heijmen, BJM
    MEDICAL PHYSICS, 1999, 26 (08) : 1524 - 1529
  • [9] Verification of compensator thicknesses using a fluoroscopic electronic portal imaging device
    Department of Clinical Physics, Daniel den Hoed Cancer Center, University Hospital Rotterdam, Groene Hilledijk 301, 3075 EA Rotterdam, Netherlands
    Med. Phys., 8 (1524-1529):
  • [10] Verification of dynamic multileaf collimation using an electronic portal imaging device
    James, HV
    Atherton, S
    Budgell, GJ
    Kirby, MC
    Williams, PC
    PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (02): : 495 - 509