Evaluation of the performance of parallel-hole collimator for high resolution small animal SPECT: A Monte Carlo study

被引:0
|
作者
Sadremomtaz, Alireza [1 ]
Telikani, Zeinab [1 ]
机构
[1] Univ Guilan, Dept Phys, Fac Sci, Rasht, Iran
来源
IRANIAN JOURNAL OF NUCLEAR MEDICINE | 2016年 / 24卷 / 02期
关键词
SPECT; Compact pixelated gamma camera; Septal penetration; Scatter; Monte Carlo simulation;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Introduction: Image quality and accuracy of in vivo activity quantification in SPECT are affected by collimator penetration and scatter components, especially in high energy imaging. These phenomena highly depend on the collimator characteristic and photon energy. The presence of penetrated and scattered photons from collimator in SPECT images degrades spatial resolution, contrast and image quality. Knowledge of penetration and scatter distribution is essential for optimization of collimator design and development of reconstruction algorithms. The aim of this study to survey the collimator performance of the newly developed HiReSPECT dual head gamma camera with pixelated array CsI(Na). Methods: We modeled the HiReSPECT, by using SIMIND Monte Carlo simulation code. The contribution of geometric, scatter and penetration components were quantitatively calculated for the different energy sources. Then we compared these results with simulation results of another small animal SPECT with compact pixelated array CsI(Tl) detector. Results: The simulated System spatial resolution and energy resolution of the HiReSPECT at 140keV respectively are 1.9mm and 29.72 keV (21.23%) FWHM at 2.5cm distance from detector surface also Geometric, penetration, and scatter at 140keV for the HiReSPECT collimator are 96.42%, 2.22%, 1.30%, respectively. Similarly, geometric, penetration, and scatter at 159keV and 245keV for this system collimator are (95.24%, 3.08%, 1.68%) and (87.21%, 8.10%, 4.69%), respectively. Conclusion: The results verified that the magnitude of these components depend on collimator geometric structure and photons energy. The measured performances indicated that the HiReSPECT scanner is well suited for preclinical molecular imaging research and provide high resolution for small animal imaging.
引用
收藏
页码:136 / 143
页数:8
相关论文
共 50 条
  • [41] MEASUREMENT OF COLLIMATOR HOLE ANGULATION AND CAMERA HEAD TILT FOR SLANT-HOLE AND PARALLEL-HOLE COLLIMATORS USED IN ROTATING CAMERA SPECT
    BUSEMANNSOKOLE, E
    JOURNAL OF NUCLEAR MEDICINE, 1986, 27 (06) : 961 - 961
  • [42] Design Optimization of a Small-animal SPECT System Using LGSO Continuous Crystals and Micro Parallel-hole Collimators
    Kim, Joong Hyun
    Ito, Mikiko
    Kim, Soo Mee
    Hong, Seong Jong
    Lee, Jae Sung
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2015, 67 (01) : 224 - 231
  • [43] COLLIMATOR PERFORMANCE EVALUATION BY MONTE-CARLO TECHNIQUES
    MILANESI, L
    BETTINARDI, V
    BELLOTTI, E
    GILARDI, MC
    TODDPOKROPEK, A
    FAZIO, F
    JOURNAL OF NUCLEAR MEDICINE, 1985, 26 (05) : P44 - P44
  • [44] Design optimization of a small-animal SPECT system using LGSO continuous crystals and micro parallel-hole collimators
    Joong Hyun Kim
    Mikiko Ito
    Soo Mee Kim
    Seong Jong Hong
    Jae Sung Lee
    Journal of the Korean Physical Society, 2015, 67 : 224 - 231
  • [45] Multi-resolution multi-sensitivity design for parallel-hole SPECT collimators
    Li, Yanzhao
    Xiao, Peng
    Zhu, Xiaohua
    Xie, Qingguo
    PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (14): : 5390 - 5405
  • [46] A Monte Carlo Simulation Study of Optimization for Collimator in a Pixelated SPECT Camera
    Telikani, Zeinab
    Sadremomtaz, Alireza
    JOURNAL OF MEDICAL IMAGING AND RADIATION SCIENCES, 2019, 50 (01) : 163 - 170
  • [47] Experimental Study of an Easily Controlled Ultra-High-Resolution Pixel-Matched Parallel-Hole Collimator with a Small Cadmium Zinc Telluride Pixelated Gamma Camera System
    Lee, Seungwan
    Kim, Hee-Joung
    Bae, Se Young
    Lee, Youngjin
    JOURNAL OF MEDICAL IMAGING AND RADIATION SCIENCES, 2016, 47 (03) : 276 - 282
  • [48] High Resolution Brain Imaging with Combined Parallel-hole and Pinhole Collimation
    Huang, Qiu
    Zeniya, Tsutomu
    Kudo, Hiroyuki
    Iida, Hidehiro
    Gullberg, Grant T.
    2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 3145 - 3148
  • [49] Feasibility of a CdTe-based SPECT for high-resolution low-dose small animal imaging: a Monte Carlo simulation study
    Park, S. -J.
    Yu, A. R.
    Lee, Y. -J.
    Kim, Y. -S.
    Kim, H. -J.
    JOURNAL OF INSTRUMENTATION, 2014, 9
  • [50] Ultra-high-resolution SPECT with CdTe for small-animal imaging applications: A Monte Carlo simulation study using a voxelized phantom
    Su-Jin Park
    Chang-Lae Lee
    Hyo-Min Cho
    Hee-Joung Kim
    Journal of the Korean Physical Society, 2012, 60 : 1145 - 1149