PROLONGED STUDIES OF PERFLUOROCARBON ASSOCIATED GAS-EXCHANGE AND OF THE RESUMPTION OF CONVENTIONAL MECHANICAL VENTILATION

被引:42
作者
SALMAN, NH
FUHRMAN, BP
STEINHORN, DM
PAPO, MC
HERNAN, LJ
LEACH, CL
FISCHER, JE
机构
[1] CHILDRENS HOSP, DIV PEDIAT CRIT CARE, BUFFALO, NY 14222 USA
[2] SUNY BUFFALO, SCH MED & BIOMED SCI, BUFFALO, NY USA
关键词
POSITIVE PRESSURE RESPIRATION; CONTINUOUS; PERFLUOROCARBON; MECHANICAL VENTILATION; HEMODYNAMICS; LIQUID VENTILATION; PULMONARY GAS EXCHANGE; BLOOD GAS ANALYSIS; CRITICAL ILLNESS; LUNGS; RESPIRATORY FAILURE; SURFACTANT;
D O I
10.1097/00003246-199505000-00021
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective: To determine whether oxygenation and lung mechanics are preserved during perfluorocarbon associated gas exchange of 24 hrs duration and after evaporation of perfluorocarbon. Design: Prospective, experimental animal trials. Setting: Animal laboratory in a university setting. Subjects: Ten normal, neonatal piglets weighing 2.5 to 4.5 kg. Interventions: Ten piglets were anesthetized with fentanyl (25 mu g/kg/hr), paralyzed with metocurine iodide (0.3 mg/kg) and placed on volume regulated continuous positive pressure breathing instituted at an Flo(2) setting of 1.0, tidal volume of 15 mL/kg, respiratory rate of 25 breaths/min and positive end-expiratory pressure of 4 cm H(2)O. Perfluorocarbon associated gas exchange was initiated by intratracheal instillation of perflouorooctylbromide (30 mL/kg) followed by gas ventilation at the same settings. Evaporative losses were replaced by intratracheal instillation of 2.5 mL/kg/hr of perfluorocarbon, In one group of five piglets, evaporative losses were replaced for 24 hrs until the end of the study. In the other group of five piglets, replacement of perfluorocarbon was discontinued after 2 hrs, although gas ventilation was continued for 24 hrs. Blood gases and lung mechanics were measured in both groups. Histologic evaluation of lungs from both groups of animals was performed. Measurements and Main Results: Airway pressures and blood gases were stable throughout the 24-hr study period in both groups, Airway pressures in the evaporative group increased as evaporation of perfluorocarbon neared completion. There was no hemodynamic deterioration during the 24-hr study period. Histology showed good preservation of lung architecture in both groups. Conclusions: Perfluorocarbon associated gas exchange was safe and effective in normal piglets for a period of 24 hrs. Evaporation of perfluorocarbon and resumption of continuous positive pressure breathing was well tolerated.
引用
收藏
页码:919 / 924
页数:6
相关论文
共 6 条
  • [1] RESPONSE OF THE RABBIT LUNG AS A CRITERION OF SAFETY FOR FLUOROCARBON BREATHING AND BLOOD SUBSTITUTES
    CLARK, LC
    HOFFMANN, RE
    DAVIS, SL
    [J]. BIOMATERIALS ARTIFICIAL CELLS AND IMMOBILIZATION BIOTECHNOLOGY, 1992, 20 (2-4): : 1085 - 1099
  • [2] PERFLUOROCARBON-ASSOCIATED GAS-EXCHANGE
    FUHRMAN, BP
    PACZAN, PR
    DEFRANCISIS, M
    [J]. CRITICAL CARE MEDICINE, 1991, 19 (05) : 712 - 722
  • [3] NESTI DF, 1994, CRIT CARE MED, V22, P1445
  • [4] Papo Michele C., 1993, Pediatric Research, V33, p39A
  • [5] Thompson Ann E., 1993, Pediatric Research, V33, p239A
  • [6] TUTUNCU AS, 1993, CRIT CARE MED, V21, P962