Acoustic Noise Levels of Dental Equipments and Its Association with Fear and Annoyance Levels among Patients Attending Different Dental Clinic Setups in Jaipur, India

被引:10
|
作者
Yousuf, Asif [1 ,2 ]
Ganta, Shravani [1 ,2 ]
Nagaraj, Anup [1 ,2 ]
Pareek, Sonia [1 ,3 ]
Atri, Mansi [1 ,4 ]
Singh, Kushpal [1 ,2 ]
Sidiq, Mohsin [1 ,5 ]
机构
[1] Jaipur Dent Coll, Dept Publ Hlth Dent, Jaipur 302028, Rajasthan, India
[2] Jaipur Dent Coll, Dept Publ Hlth Dent, Jaipur, Rajasthan, India
[3] Govt Dent Coll, Dept Publ Hlth Dent, Jaipur, Rajasthan, India
[4] ESIC Dent Coll & Hosp, Dept Publ Hlth Dent, Delhi, India
[5] Govt Dent Coll, Dept Pedodont, Srinagar 190010, Jammu & Kashmir, India
关键词
Noise; Occupational; Noise induced hearing loss; Sound; Fear;
D O I
10.7860/JCDR/2014/7678.4245
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Noise is a source of pervasive occupational hazard for practicing dentists and the patients. The sources of dental sounds by various dental equipments can pose as a potential hazard to hearing system and add to the annoyance levels of the patients. The aim of the study was to analyze the noise levels from various equipments and evaluate the effect of acoustic noise stimulus on dental fear and annoyance levels among patients attending different dental clinic setups in Jaipur, India. Methodology: The sampling frame comprised of 180 patients, which included 90 patients attending 10 different private clinics and 90 patients attending a Dental College in Jaipur. The levels of Acoustic Noise Stimulus originating from different equipments were determined using a precision sound level meter/decibulo-Fear Scale (DFS). Results: Statistical analysis was performed using chi square test and unpaired t-test. The mean background noise levels were found to be maximum in the pre-clinical setup/laboratory areas (69.23 +/- 2.20). Females and the patients attending dental college setup encountered more fear on seeing the drill as compared to the patients attending private clinics (p<0.001). Conclusion: The sources of dental sounds can pose as a potential hazard to hearing system. It was analyzed that the environment in the clinics can directly have an effect on the fear and annoyance levels of patients. Hence it is necessary control the noise from various dental equipments to reduce the fear of patients from visiting a dental clinic.
引用
收藏
页码:ZC29 / ZC34
页数:6
相关论文
共 4 条
  • [1] Dental fear and anxiety levels of patients attending a dental clinic
    Erten, Huelya
    Akarslan, Zuehre Zafersoy
    Bodrumlu, Emre
    QUINTESSENCE INTERNATIONAL, 2006, 37 (04): : 304 - 310
  • [2] Association of Fear and Annoyance with Acoustic Levels of Dental Equipment Among Adolescents Attending Rural Dental Health Center: A Cross-sectional Study
    Gadupudi, Salini
    Siddanna, Sunitha
    Chandrashekar, Byalakere R.
    Rudraswamy, Sushma
    OPEN DENTISTRY JOURNAL, 2021, 15 : 595 - 600
  • [3] Comparison of anxiety levels associated with noise in the dental clinic among children of age group 6-15 years
    Muppa, Radhika
    Bhupatiraju, Prameela
    Duddu, Mahesh
    Penumatsa, Narendra Varma
    Dandempally, Arthi
    Panthula, Priyanka
    NOISE & HEALTH, 2013, 15 (64) : 190 - 193
  • [4] A cross sectional study on levels of dental anxiety, its influencing factors, and the preferred management techniques among patients in Riyadh, Saudi Arabia
    Alowid, Albandri Mohammed
    Hebbal, Mamata
    Aldegheishem, Alhanoof
    Nadakkavukaran Santhosh, Varkey
    Surath Kumar, Ram
    Alfayyadh, Atheer Mohammed
    Alateeq, Njoud Ibrahim
    Alomran, Sara Mazen
    Aleban, Shog Abdulelah
    PLOS ONE, 2024, 19 (09):