DOUBLE-BLIND COMPARISON OF SAFETY AND EFFICACY OF IOMEPROL AND IOPAMIDOL IN CAROTID DIGITAL SUBTRACTION ANGIOGRAPHY

被引:4
|
作者
BELTRAMELLO, A
PIOVAN, E
ROSTA, L
机构
[1] Institute of Radiology, Verona University Hospital, Policlinico Borgo Roma, 37100 Verona, Via delle Menegone
[2] Department of Neuroradiology, Borgo Trento Hospital, Verona
关键词
CONTRAST MEDIA; EFFICACY STUDY; COMPARATIVE STUDY; ANGIOGRAPHY; DSA;
D O I
10.1016/0720-048X(94)90096-5
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Iomeprol is a nonionic monomer which provides injectable formulations with the lowest osmolalities and the lowest viscosities among the currently available low-osmolar radiographic contrast agents of the same category. These favourable physico-chemical characteristics, together with high water solubility and low molecular toxicity, make this agent particularly suitable for carotid angiography, a procedure in which contrast-induced blood-brain barrier damage is maximal. This single-centre, randomised, double-blind, parallel-group study aimed at comparing the safety, tolerance and efficacy of 200 mgI/ml solutions of iomeprol and iopamidol in 100 consenting adult inpatients undergoing carotid intra-arterial digital subtraction angiography (IA-DSA). Both agents appeared to be safe and well tolerated. Only minor and transient adverse events occurred throughout the study. Electroencephalographic and neurological examinations performed pre- and post-contrast showed no abnormality induced by the test compounds. Vessel opacification was good or excellent in the vast majority of technically adequate examinations. Information provided by the angiographic examination was useful for subsequent patient management in almost all cases. It is concluded that iomeprol-200 and iopamidol-200 are safe and effective contrast media when used for carotid IA-DSA, an examination which proves useful not only for the diagnosis of vascular lesions, but also to best direct the management of patients scheduled for surgery of intracranial tumors.
引用
收藏
页码:S67 / S72
页数:6
相关论文
共 50 条
  • [41] IOVERSOL 300 AND IOPAMIDOL 300 IN WHOLE-BODY COMPUTED-TOMOGRAPHY - A DOUBLE-BLIND CLINICAL-TRIAL
    CHAGNAUD, C
    MOULIN, G
    DELANNOY, L
    GAUBERT, JY
    HADDAD, D
    BARTOLI, JM
    KASBARIAN, M
    ANNALES DE RADIOLOGIE, 1992, 35 (4BIS) : 276 - 279
  • [42] Detection of thrombosis in the portal venous system: Comparison of contrast-enhanced MR angiography with intraarterial digital subtraction angiography
    Kreft, B
    Strunk, H
    Flacke, S
    Wolff, M
    Conrad, R
    Gieseke, J
    Pauleit, D
    Bachmann, R
    Hirner, A
    Schild, HH
    RADIOLOGY, 2000, 216 (01) : 86 - 92
  • [43] Multislice CT angiography in renal artery stent evaluation: Prospective comparison with intra-arterial digital subtraction angiography
    Raza, SA
    Chughtai, AR
    Wahba, M
    Cowling, MG
    Taube, D
    Wright, AR
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2004, 27 (01) : 9 - 15
  • [44] CT Angiography, MR Angiography, and Their Combined Use for Detection of Unruptured Intracranial Aneurysms: Comparison with Digital Subtraction Angiography and 3-dimensional Rotational Angiography
    Lim, Jee Hyun
    Yoon, Dae Young
    Kim, Eun Soo
    Jeon, Hong Jun
    Lee, Jong Young
    Seo, Young Lan
    Yun, Eun Joo
    CLINICAL NEURORADIOLOGY, 2025,
  • [45] RANDOMIZED DOUBLE-BLIND TRIAL OF THE SAFETY AND EFFICACY OF 2 GADOLINIUM COMPLEXES (GD-DTPA AND GD-DOTA)
    BRUGIERES, P
    GASTON, A
    DEGRYSE, HR
    PARIZEL, PM
    DESCHEPPER, AM
    BERRY, I
    MANELFE, C
    LEBRAS, F
    MARSAULT, C
    WICHMANN, W
    VALAVANIS, A
    NEURORADIOLOGY, 1994, 36 (01) : 27 - 30
  • [46] Comparison between 64-row CT angiography and digital subtraction angiography in the study of lower extremities: personal experience
    Cernic, S.
    Mucelli, F. Pozzi
    Pellegrin, A.
    Pizzolato, R.
    Cova, M. A.
    RADIOLOGIA MEDICA, 2009, 114 (07): : 1115 - 1129
  • [47] Comparison of asymmetry in cerebral blood flow between brain hemispheres using digital subtraction angiography
    Divani, AA
    Qureshi, AI
    Hoffman, KR
    Suri, MFK
    Kirmani, JF
    JOURNAL OF NEUROIMAGING, 2006, 16 (02) : 139 - 145
  • [48] Accuracy of Computed Tomography Angiography for Diagnosing Extracranial Mural Lesions in Patients with Acute Internal Carotid Artery Occlusion: Correlation with Digital Subtraction Angiography
    Fernandez-Gomez, Miriam
    Gallo-Pineda, Felix
    Hidalgo-Barranco, Carlos
    Castro-Luna, Gracia
    Martinez-Sanchez, Patricia
    JOURNAL OF PERSONALIZED MEDICINE, 2023, 13 (07):
  • [49] Gadolinium dimeglumine as a contrast agent for digital subtraction angiography:: in vitro Hounsfield unit measurement and clinical efficacy
    Kim, MD
    Kim, H
    YONSEI MEDICAL JOURNAL, 2003, 44 (01) : 138 - 142
  • [50] Comparison of Safety and Diagnostic Efficacy of Iohexol 240 mgI/mL, Iopamidol 250 mgI/mL, and Iodixanol 270 mgI/mL in Cerebral Angiography: A Prospective, Multicenter Study
    Baek, Jinwook
    Jeong, Hae Woong
    Heo, Young Jin
    Yun, Suyoung
    Kang, Myongjin
    Kim, Byungjun
    Kim, Eui Jong
    Lim, Soo Mee
    Lee, Boeun
    NEUROINTERVENTION, 2024, 19 (02) : 82 - 91