RECIPROCITY CALIBRATION OF ULTRASONIC CONTACT TRANSDUCERS

被引:2
作者
FAY, B
REIMANN, HP
机构
[1] Physikalisch—Technische Bundesanstalt
关键词
D O I
10.1109/58.265829
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
The extension of the reciprocity calibration method widely used in medical ultrasonics to nondestructive pulse-echo transducers is presented. It is shown that the self-reciprocity procedure originally developed for immersion transducers can also be applied to contact transducers, which are mainly used for the investigation of solids. The sensitivity of the contact transducers used was calculated with the help of two models which simulate the behavior of the transmitter-receiver arrangement within the whole frequency range investigated, namely 2-12 MHz. The procedure needed to determine the diffraction losses associated with the test objects such as half cylinders and half spheres is also presented. Half cylinders or half spheres are needed when the ultrasonic wave does not have a normal incidence on the test object. The calculated diffraction loss for the half cylinder was also experimentally verified. Good agreement obtained between diffraction loss measurements and the model predictions confirms that the calculated diffraction loss of the half cylinder is suitable for use in practical investigations. The calibration procedure described enables ultrasonic measurements performed with different contact transducers and devices to be compared. This is of great importance in many applications, as for example in periodic routine inspections of the components of nuclear facilities.
引用
收藏
页码:123 / 129
页数:7
相关论文
共 50 条
[41]   Time domain self-reciprocity calibration of ultrasonic transducer [J].
Deng, MX ;
Lin, JB ;
Shui, YA .
ACTA PHYSICA SINICA-OVERSEAS EDITION, 1999, 8 :S48-S52
[42]   REINTERPRETATION OF THE RECIPROCITY THEOREM FOR THE CALIBRATION OF ACOUSTIC-EMISSION TRANSDUCERS OPERATING ON A SOLID [J].
HILL, R ;
ADAMS, NL .
ACUSTICA, 1979, 43 (05) :305-312
[43]   Ultrasonic Response of Polymers by Non-contact Transducers [J].
Petculescu, Petre ;
Zagan, Remus ;
Dimitrescu, Dan .
MATERIALE PLASTICE, 2008, 45 (03) :246-250
[44]   Rayleigh Wave Calibration of Acoustic Emission Sensors and Ultrasonic Transducers [J].
Ono, Kanji .
SENSORS, 2019, 19 (14)
[45]   APPLICATION OF TIME-DELAY SPECTROMETRY FOR CALIBRATION OF ULTRASONIC TRANSDUCERS [J].
PEDERSEN, PC ;
LEWIN, PA ;
BJORNO, L .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1988, 35 (02) :185-205
[46]   A self-reciprocity calibration of spherical transducers using boundary reflection in a spherical shell [J].
Yang, Liuqing ;
Zhang, Jun .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2024, 156 (02) :1041-1047
[47]   THE PLANE WAVE RECIPROCITY PARAMETER AND ITS APPLICATION TO THE CALIBRATION OF ELECTROACOUSTIC TRANSDUCERS AT CLOSE DISTANCES [J].
SIMMONS, BD ;
URICK, RJ .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1949, 21 (06) :633-635
[48]   Ultrasonic testing of an ice specimen by the dry point contact transducers [J].
Nesvijski, EG .
ASNT FALL CONFERENCE AND QUALITY TESTING SHOW PAPER SUMMARIES, 1999, :99-101
[49]   Nonlinearity harmonic at contact interface in ultrasonic transducers bonding system [J].
Li, Zhan-Hui ;
Wu, Yun-Xin ;
Long, Zhi-Li .
Zhendong yu Chongji/Journal of Vibration and Shock, 2010, 29 (09) :138-141
[50]   Calibration of therapeutic ultrasonic transducers with the modified radiation force balance system [J].
Karaboce, Baki ;
Durmus, Huseyin Okan ;
Cetin, Emel ;
Ozdingis, Mithat .
2017 IEEE INTERNATIONAL SYMPOSIUM ON MEDICAL MEASUREMENTS AND APPLICATIONS (MEMEA), 2017, :83-87