ROTATING-RING-DISK ELECTRODE STUDIES OF POLYPYRROLE-GLUCOSE OXIDASE BIOSENSORS

被引:20
作者
BELANGER, D
NADREAU, J
FORTIER, G
机构
[1] Département de Chimie, Université du Québec Á Montréal, Montréal, Quebec, H3C 3P8
关键词
GLUCOSE BIOSENSOR; POLYPYRROLE; ROTATING RING-DISK ELECTRODE;
D O I
10.1002/elan.1140041004
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A rotating ring-disk electrode, (RRDE) of which the platinum disk was coated with a polypyrrole-glucose oxidase (PPy-GOD) film by electrochemical polymerization and the ring was left bare, has been used to characterize the PPy-GOD electrode. Polypyrrole-GOD films of various thicknesses grown in the presence of 100 and 500 U/ml of GOD in the deposition solution were used. The amperometric current generated at 0.7 V versus saturated calomel electrode (SCE) by the electrochemical oxidation of hydrogen peroxide, generated by the enzymatic reaction, has been evaluated at both the coated disk and uncoated ring at various rotation speeds. The collection efficiency of the RRDE was 22% and was used to evaluate the total current of the PPy-GOD electrode. The total current of a polypyrrole electrode was defined as the sum of the disk current and the total ring current taken as the observed ring current divided by the collection efficiency of the RRDE. From this study, it clearly appears that the biotransformation of glucose takes place mainly at the polypyrrole film/solution interface independently of the rotation speed and that the catalysis is not limited by oxygen. The Eadie-Hofstee type plots obtained for disk current with 10-225 mM of glucose show a strong positive deviation for glucose concentrations higher than 100 mM. On the other hand, linear plots are obtained when the total current of the enzyme electrode is considered. No definitive explanation can be given for these behaviors, except that at a higher glucose concentration, the flux of glucose is high enough to permit the diffusion of glucose deeper in the film, where it can be oxidized by the enzyme. Thus, the catalytic reaction is taking place in a thicker layer of the film.
引用
收藏
页码:933 / 940
页数:8
相关论文
共 50 条
  • [31] Amperometric glucose biosensors based on layer-by-layer assembly of chitosan and glucose oxidase on the Prussian blue-modified gold electrode
    Bing Yin
    Ruo Yuan
    Yaqing Chai
    Shihong Chen
    Shurui Cao
    Yang Xu
    Ping Fu
    Biotechnology Letters, 2008, 30 : 317 - 322
  • [32] Amperometric glucose biosensors based on layer-by-layer assembly of chitosan and glucose oxidase on the Prussian blue-modified gold electrode
    Yin, Bing
    Yuan, Ruo
    Chai, Yaqing
    Chen, Shihong
    Cao, Shurui
    Xu, Yang
    Fu, Ping
    BIOTECHNOLOGY LETTERS, 2008, 30 (02) : 317 - 322
  • [33] Glucose biosensor based on glucose oxidase immobilized in electropolymerized polypyrrole and poly(o-phenylenediamine) films on a Prussian Blue-modified electrode
    Garjonyte, R
    Malinauskas, A
    SENSORS AND ACTUATORS B-CHEMICAL, 2000, 63 (1-2) : 122 - 128
  • [34] Rotating ring-disk electrode study of high-rate copper dissolution in hydrochloric acid solution
    D'Elia, E
    Barcia, OE
    Mattos, OR
    Pébère, N
    Tribollet, B
    ELECTROCHEMICAL METHODS IN CORROSION RESEARCH VI, PTS 1 AND 2, 1998, 289-2 : 861 - 869
  • [35] Rotating ring-disk studies of oxidized nickel hydrous oxide: oxygen evolution and pseudocapacitance
    Hu, YN
    Tolmachev, YV
    Scherson, DA
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1999, 468 (01): : 64 - 69
  • [36] Measurement of competition between oxygen evolution and chlorine evolution using rotating ring-disk electrode voltammetry
    Vos, J. G.
    Koper, M. T. M.
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2018, 819 : 260 - 268
  • [37] Glucose biosensor based on immobilization of glucose oxidase in poly(o-aminophenol) film on polypyrrole-Pt nanocomposite modified glassy carbon electrode
    Li, Jing
    Lin, Xiangqin
    BIOSENSORS & BIOELECTRONICS, 2007, 22 (12) : 2898 - 2905
  • [38] Rotating ring-disk electrode measurements on Mn dissolution and capacity losses of spinel electrodes in various organic electrolytes
    Chen, Jenn-Shing
    Wang, Li-Fang
    Fang, Bor-Jian
    Lee, Shao-Yung
    Guo, Ren-Zheng
    JOURNAL OF POWER SOURCES, 2006, 157 (01) : 515 - 521
  • [39] Separation of Oxygen Reduction Reaction from Total Reduction Current on Pt/C Using Rotating Ring Disk Electrode
    Mitsushima, Shigenori
    Fujita, Yoshio
    Nagahara, Yoshiki
    Sugawara, Seiho
    Matsuzawa, Koichi
    Shinohara, Kazuhiko
    Ota, Ken-ichiro
    ELECTROCHEMISTRY, 2011, 79 (01) : 24 - 29
  • [40] Studies on the electrochemical performance of glucose biosensor based on ferrocene encapsulated ORMOSIL and glucose oxidase modified graphite paste electrode
    Pandey, PC
    Upadhyay, S
    Shukla, NK
    Sharma, S
    BIOSENSORS & BIOELECTRONICS, 2003, 18 (10) : 1257 - 1268