POLYMERIC COATINGS IN PACKED FUSED-SILICA MICRO-LC COLUMNS

被引:8
|
作者
GHIJS, M
SANDRA, P
机构
[1] Laboratory of Organic Chemistry, State University of Gent, Gent, B-9000
关键词
MICRO-LIQUID CHROMATOGRAPHY; POLYMERIC COATINGS; CYANOPROPYL POLYSILOXANE; OCTADECYL POLYSILOXANE; POLYETHYLENE GLYCOL;
D O I
10.1002/mcs.1220030509
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Different polymer-coated stationary phases have been evaluated in micro-LC: Nucleosil-100-5-C1-PMSC18 (C18-substituted polymethylsiloxane, C1-deactivated with trimethylsilylenolate) and Nucleosil-100-5-C1-PMSCN (cyanopropyl-substituted polymethylsiloxane, C1-deactivated) in the reversed phase mode and Nucleosil-100-5-PEG (polyethylene glycol-coated) in the normal phase mode. Fused silica tubing of 320-mu-m i.d. was slurry packed with suspensions optimized for each packing material. The micropacked columns were studied for efficiency and selectivity. The silanol activities of the polymer coated phases were compared to monomeric phases for the reversed phase mode and to silica for the normal phase mode.
引用
收藏
页码:443 / 448
页数:6
相关论文
共 50 条
  • [41] HYBRID FUSED-SILICA GLASS-CAPILLARY COLUMNS FOR GLC
    ROHWER, ER
    PRETORIUS, V
    JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY & CHROMATOGRAPHY COMMUNICATIONS, 1987, 10 (03): : 145 - 147
  • [42] KOVATS INDEXES OF DITERPENE HYDROCARBONS ON FUSED-SILICA CAPILLARY COLUMNS
    PERRY, NB
    WEAVERS, RT
    JOURNAL OF CHROMATOGRAPHY, 1984, 284 (02): : 478 - 481
  • [43] SEPARATION OF MONOSACCHARIDES AS TRIMETHYLSILYLATED ALDITOLS ON FUSED-SILICA CAPILLARY COLUMNS
    BRADBURY, AGW
    HALLIDAY, DJ
    MEDCALF, DG
    JOURNAL OF CHROMATOGRAPHY, 1981, 213 (01): : 146 - 150
  • [44] SIMPLE METHOD FOR SEALING THE ENDS OF FUSED-SILICA CAPILLARY COLUMNS
    CALDER, AG
    JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY & CHROMATOGRAPHY COMMUNICATIONS, 1982, 5 (06): : 324 - 324
  • [45] PORE-SIZE INFLUENCE IN CHIRAL PACKED-COLUMN MICRO-LC
    SVENSSON, LA
    KARLSSON, KE
    JOURNAL OF MICROCOLUMN SEPARATIONS, 1995, 7 (03) : 231 - 237
  • [46] Fused-Silica Micro Birdbath Resonator Gyroscope (μ-BRG)
    Cho, Jae Yoong
    Woo, Jong-Kwan
    Yan, Jialiang
    Peterson, Rebecca L.
    Najafi, Khalil
    JOURNAL OF MICROELECTROMECHANICAL SYSTEMS, 2014, 23 (01) : 66 - 77
  • [47] AUTOMATED QUARTZ INJECTOR TRAP FOR FUSED-SILICA CAPILLARY COLUMNS
    RODRIGUEZ, PA
    EDDY, CL
    RIDDER, GM
    CULBERTSON, CR
    JOURNAL OF CHROMATOGRAPHY, 1982, 236 (01): : 39 - 49
  • [48] MICRO-HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH LONG MICROPACKED FLEXIBLE FUSED-SILICA COLUMNS
    TAKEUCHI, T
    ISHII, D
    JOURNAL OF CHROMATOGRAPHY, 1982, 238 (02): : 409 - 418
  • [49] Fused-silica packed microcolumns in high-performance liquid chromatography
    Ruban, VF
    Nasledov, DG
    Chernitsa, BV
    JOURNAL OF ANALYTICAL CHEMISTRY, 1996, 51 (11) : 1057 - 1060
  • [50] FUSED-SILICA PACKED MICROCOLUMNS AS MICROPREPARATIVE TOOLS IN PROTEIN ANALYTICAL STUDIES
    FLURER, C
    BORRA, C
    BEALE, S
    NOVOTNY, M
    ANALYTICAL CHEMISTRY, 1988, 60 (17) : 1826 - 1829