BIOLOGICAL MONITORING OF NITROUS-OXIDE EXPOSURE IN SURGICAL AREAS

被引:12
作者
TREVISAN, A
GORI, GP
机构
[1] Istituto di Medicina Del Lavoro, Università di Padova, Padova
[2] Istituto di Medicina Del Lavoro, Universitá di Padova, Padova
关键词
biological monitoring; nitrous oxide; surgical room personnel;
D O I
10.1002/ajim.4700170308
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Exposure to nitrous oxide in surgical theaters was evaluated for duration, numbers, and types of surgical procedures. The concentration of the gas in the air was 92‐444 ppm. Before and after the surgical sessions, samples of urine and expired air were collected from surgical theater personnel for gas determination. Nitrous oxide concentrations in urine and in expired air showed a good correlation with gas concentration in the air (r = 0.760 and r = 0.921, respectively). Moreover, a good correlation (r = 0.823) between gas concentration in urine and that in expired air was also found. A biological threshold limit value (TLV) of 20.6 m̈g/liter for urine and of 29.6 ppm for expired air was calculated, based on the limit of 50 ppm in the air proposed by the American Conference of Governmental Industrial Hygienists (ACGIH). Other biological TLVs corresponding to higher proposed limits (200 and 500 ppm) were also calculated. Copyright © 1990 Wiley Periodicals, Inc., A Wiley Company
引用
收藏
页码:357 / 362
页数:6
相关论文
共 23 条
[1]  
ASKROG V, 1970, Nordisk Medicin, V83, P498
[2]  
BRODSKY JB, 1983, CLIN ANAESTHESIOL, V1, P455
[3]   COBALAMINS AND NITROUS-OXIDE - A REVIEW [J].
CHANARIN, I .
JOURNAL OF CLINICAL PATHOLOGY, 1980, 33 (10) :909-916
[4]  
COLTON T, 1982, EVALUATION EPIDEMIOL
[5]  
GARSTKA K, 1974, 159TH M LOW RHIN WES
[6]  
Ghittori S, 1983, G Ital Med Lav, V5, P251
[7]  
GOTHE C J, 1976, Lakartidningen, V73, P2553
[8]  
GREEN CD, 1963, ANESTHESIOLOGY, V24, P341, DOI 10.1097/00000542-196305000-00015
[9]  
KNILLJON.RP, 1972, LANCET, V1, P1326
[10]  
KOBLIN DD, 1982, ANESTH ANALG, V61, P75