NONINVASIVE VS INVASIVE BEAT-TO-BEAT MONITORING OF BLOOD-PRESSURE

被引:37
|
作者
GABRIEL, A
LINDBLAD, LE
ANGLERYD, C
机构
[1] Department of Clinical Physiology, Södersjukhuset, Stockholm
来源
CLINICAL PHYSIOLOGY | 1992年 / 12卷 / 02期
关键词
MONITORING BLOOD PRESSURE; FINGER BLOOD PRESSURE; NONINVASIVE; INVASIVE;
D O I
10.1111/j.1475-097X.1992.tb00309.x
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
The present study focuses on the accuracy in tracing fast beat-to-beat changes in blood pressure using a non-invasive technique. The measurements using a commercially available apparatus (Finapres, Ohmeda, USA) were compared to ipsilateral intra-arterial radial pressure. Eight patients were studied at rest, during deep breathing with a fixed rate of 6 breaths min-1, and during an exercise test on an ergometer cycle. A total of 900 systolic pressure values were included for statistical evaluation, covering a pressure range of 86-266 mmHg. On average the systolic correlation coefficient for the whole material was 0.97, with a range of 0.94-0.996. For mean pressure the correlation coefficient was on average 0.97, and for diastolic pressure 0.93. No systematic difference between the non-invasive and the invasive method was found, although for each individual patient a difference between direct and indirect measured blood pressure existed that could be relatively large (systolic pressure: average difference = 0.8 mmHg, SD = 16 mmHg). We found the method easy to handle and consider it excellently suited to track relative changes in blood pressure.
引用
收藏
页码:229 / 235
页数:7
相关论文
共 50 条
  • [21] Baroreflex failure and beat-to-beat blood pressure variation
    Takuya Kishi
    Hypertension Research, 2018, 41 : 547 - 552
  • [22] NONINVASIVE BEAT-TO-BEAT ARTERIAL BLOOD-PRESSURE DURING NON-REM SLEEP IN OBSTRUCTIVE SLEEP-APNEA AND SNORING
    DAVIES, RJO
    CROSBY, J
    VARDIVISY, K
    CLARKE, M
    STRADLING, JR
    THORAX, 1994, 49 (04) : 335 - 339
  • [23] Blood pressure measurement during cesarean delivery Evaluation of a beat-to-beat noninvasive device (NexfinTM)
    Bobet, Mathieu
    Joachim, Jona
    Gayat, Etienne
    Bonnet, Agnes
    Sievert, Kerstin
    Barnichon, Carole
    Fischler, Marc
    Le Guen, Morgan
    MEDICINE, 2021, 100 (22) : E26129
  • [24] Beat-to-beat blood pressure measurement using a cuffless device does not accurately reflect invasive blood pressure
    Moharram, Mohammed A.
    Wilson, Luke C.
    Williams, Michael J. A.
    Coffey, Sean
    INTERNATIONAL JOURNAL CARDIOLOGY HYPERTENSION, 2020, 5
  • [25] ELECTRONIC CIGARETTE ACUTELY INCREASES BLOOD PRESSURE IN HYPERTENSIVE PATIENTS. EVALUATION BY NON - INVASIVE CONTINUOUS (BEAT-TO-BEAT) BLOOD PRESSURE MONITORING
    Crippa, Giuseppe
    Balordi, Valentina
    Bravi, Elena
    Fontana, Manuela
    JOURNAL OF HYPERTENSION, 2018, 36 : E168 - E168
  • [26] A PRELIMINARY-STUDY OF BEAT-TO-BEAT BLOOD-PRESSURE BIOFEEDBACK USING THE VASCULAR UNLOADING METHOD
    SAWADA, Y
    YAMAKOSHI, K
    JAPANESE PSYCHOLOGICAL RESEARCH, 1991, 33 (01) : 42 - 47
  • [27] THE BEAT-TO-BEAT BLOOD-PRESSURE RESPONSE TO POSTURAL CHANGE IN YOUNG AND ELDERLY HEALTHY ADULT MALES
    GOLDSTEIN, IB
    SHAPIRO, D
    JOURNAL OF BEHAVIORAL MEDICINE, 1990, 13 (05) : 437 - 448
  • [28] Beat-to-Beat Blood Pressure Variability and Cognition in the MIDUS Study
    Sweigert, Joshua
    McKinley, Paula
    Lachman, Margie
    Gruenewald, Tara
    Seeman, Teresa
    Love, Gayle
    Weinstein, Maxine
    McIntyre, Kathleen
    Duong, Jimmy
    Sloan, Richard P.
    PSYCHOSOMATIC MEDICINE, 2017, 79 (04): : A154 - A155
  • [29] Toe photoplethysmographic monitor, a promising noninvasive technique for tracking systolic blood pressure trends beat-to-beat
    Fu, Zhi Qing
    Fan, Jin
    Wang, Yu Tang
    BLOOD PRESSURE MONITORING, 2014, 19 (04) : 246 - 248
  • [30] BEAT-TO-BEAT VARIABILITY OF HEART INTERVAL AND BLOOD PRESSURE.
    De Boer, Roel W.
    Karemaker, John M.
    Strackee, Jan
    1600, (04):