NONINVASIVE VS INVASIVE BEAT-TO-BEAT MONITORING OF BLOOD-PRESSURE

被引:37
|
作者
GABRIEL, A
LINDBLAD, LE
ANGLERYD, C
机构
[1] Department of Clinical Physiology, Södersjukhuset, Stockholm
来源
CLINICAL PHYSIOLOGY | 1992年 / 12卷 / 02期
关键词
MONITORING BLOOD PRESSURE; FINGER BLOOD PRESSURE; NONINVASIVE; INVASIVE;
D O I
10.1111/j.1475-097X.1992.tb00309.x
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
The present study focuses on the accuracy in tracing fast beat-to-beat changes in blood pressure using a non-invasive technique. The measurements using a commercially available apparatus (Finapres, Ohmeda, USA) were compared to ipsilateral intra-arterial radial pressure. Eight patients were studied at rest, during deep breathing with a fixed rate of 6 breaths min-1, and during an exercise test on an ergometer cycle. A total of 900 systolic pressure values were included for statistical evaluation, covering a pressure range of 86-266 mmHg. On average the systolic correlation coefficient for the whole material was 0.97, with a range of 0.94-0.996. For mean pressure the correlation coefficient was on average 0.97, and for diastolic pressure 0.93. No systematic difference between the non-invasive and the invasive method was found, although for each individual patient a difference between direct and indirect measured blood pressure existed that could be relatively large (systolic pressure: average difference = 0.8 mmHg, SD = 16 mmHg). We found the method easy to handle and consider it excellently suited to track relative changes in blood pressure.
引用
收藏
页码:229 / 235
页数:7
相关论文
共 50 条
  • [1] SLEEP QUALITY AND CONTINUOUS, NONINVASIVE BEAT-TO-BEAT BLOOD-PRESSURE RECORDING
    VANDEBORNE, P
    NGUYEN, H
    LINKOWSKI, P
    DEGAUTE, JP
    JOURNAL OF HYPERTENSION, 1993, 11 (12) : 1423 - 1427
  • [2] Non-invasive beat-to-beat blood pressure monitoring: new developments
    Parati, G
    Ongaro, G
    Bilo, G
    Glavina, F
    Castiglioni, P
    Di Rienzo, M
    Mancia, G
    BLOOD PRESSURE MONITORING, 2003, 8 (01) : 31 - 36
  • [3] BEAT-TO-BEAT BLOOD-PRESSURE RESPONSE IN ASYMPTOMATIC IDDM SUBJECTS
    GOLDSTEIN, IB
    NALIBOFF, BD
    SHAPIRO, D
    FRANK, HJL
    DIABETES CARE, 1988, 11 (10) : 774 - 779
  • [4] BEAT-TO-BEAT AGREEMENT OF NONINVASIVE FINGER ARTERY AND INVASIVE RADIAL ARTERY BLOOD-PRESSURE IN HYPERTENSIVE PATIENTS TAKING CARDIOVASCULAR MEDICATION
    LINDQVIST, A
    CLINICAL PHYSIOLOGY, 1995, 15 (03): : 219 - 229
  • [5] Application of Nexfin noninvasive beat-to-beat arterial blood pressure monitoring in autonomic function testing
    Sipkens, Laura M.
    Treskes, Kaij
    Ariese-Beldman, Karin
    Veerman, Derk P.
    Boer, Christa
    BLOOD PRESSURE MONITORING, 2011, 16 (05) : 246 - 251
  • [6] NON INVASIVE, BEAT-TO-BEAT, INVESTIGATION OF THE EFFECTS OF POSTURE ON ARTERIAL BLOOD-PRESSURE IN DIABETIC NEUROPATHY
    SCHEEN, AJ
    JUCHMES, J
    POCHET, T
    MARFELLA, R
    DIMARO, G
    LEFEBVRE, PJ
    DIABETES & METABOLISM, 1990, 16 (4BIS): : 382 - 384
  • [7] Soft Wearable Pressure Sensors for Beat-to-Beat Blood Pressure Monitoring
    Kim, Joshua
    Chou, En-Fan
    Le, Jamie
    Wong, Sabrina
    Chu, Michael
    Khine, Michelle
    ADVANCED HEALTHCARE MATERIALS, 2019, 8 (13)
  • [8] TRACKING-CUFF SYSTEM FOR BEAT-TO-BEAT RECORDING OF BLOOD-PRESSURE
    SHAPIRO, D
    GREENSTADT, L
    LANE, JD
    RUBINSTEIN, E
    PSYCHOPHYSIOLOGY, 1981, 18 (02) : 129 - 136
  • [9] Beat-to-beat blood-pressure measurements applied in studies on mental workload
    vanRoon, AM
    Mulder, LJM
    Veldman, JBP
    Mulder, G
    HOMEOSTASIS IN HEALTH AND DISEASE, 1995, 36 (5-6): : 316 - 324
  • [10] COMPARISON OF FINAPRES NONINVASIVE BEAT-TO-BEAT FINGER BLOOD-PRESSURE WITH INTRABRACHIAL ARTERY PRESSURE DURING AND AFTER BICYCLE ERGOMETRY
    IDEMA, RN
    VANDENMEIRACKER, AH
    IMHOLZ, BPM
    INTVELD, AJM
    SETTELS, JJ
    VANECK, HJR
    SCHALEKAMP, MADH
    JOURNAL OF HYPERTENSION, VOL 7, SUPPL 6: PROCEEDINGS OF THE FOURTH EUROPEAN MEETING ON HYPERTENSION, 1989, : S58 - S59