INDOMETHACIN ION-SELECTIVE ELECTRODE BASED ON A BIS(TRIPHENYLPHOSPHORANYLIDENE)AMMONIUM INDOMETHACIN COMPLEX

被引:18
|
作者
AUBECK, R [1 ]
BRAUCHLE, C [1 ]
HAMPP, N [1 ]
机构
[1] UNIV MUNICH,INST PHYS CHEM,SOPHIENSTR 11,W-8000 MUNICH 2,GERMANY
关键词
INDOMETHACIN DETERMINATION; ION-SELECTIVE ELECTRODE; PERCHLORATE/PERIODATE DETERMINATION;
D O I
10.1039/an9911600811
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The properties of an ion-selective electrode for indomethacin based on the bis(triphenylphosphoranylidene) ammonium-indomethacin ion-pair complex in a poly(vinyl chloride) membrane are described. The detection limit found for indomethacin at pH 7.0 was 2 x 10(-5) mol 1-1 (6.4-mu-g ml-1) and the linear range was determined to be between 5 x 10(-5) and greater-than-or-equal-to 10(-3) mol l-1. The selectivity coefficients observed for organic anions of different lipophilicity were 10(-1.1) for naproxenate, 10(-0.75) for salicylate and < 10(-4) for tartrate. Cationic organic and inorganic ions showed negligible interference with selectivity coefficients of < 10(-4). A strong electrode response was observed for the inorganic anions IO4-, CIO4- and SCN- with selectivity coefficients of up to 10(+0.9). Very low detection limits, e.g., 6 x 10(-7) mol l-1 (60 ng ml-1) for CIO4- were found. The selectivity for inorganic anions was close to the Hofmeister series.
引用
收藏
页码:811 / 814
页数:4
相关论文
共 50 条
  • [21] Application of promazine compound with cadmium tetraiodide complex in the liquid membrane of an ion-selective electrode
    Magnuszewska, B
    Figaszewski, Z
    CHEMIA ANALITYCZNA, 1998, 43 (02): : 265 - 273
  • [22] Determination of Thiocyanate Ion by Ion-selective Electrode Using Schiff Base Complex of Cu(II) as an Ionophore
    Singh, Sanjay
    Singh, Aishwarya
    Yadav, Kalash Chandra
    Singh, Arpit
    Singh, Gyanendra
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2012, 4 (02): : 163 - 177
  • [23] Calixazacrown ethers for copper(II) ion-selective electrode
    Park, SJ
    Shon, OJ
    Rim, JA
    Lee, JK
    Kim, JS
    Nam, H
    Kim, H
    TALANTA, 2001, 55 (02) : 297 - 304
  • [24] Ion-selective electrode for salicylate assay in blood serum
    Katsu, T
    Mori, Y
    TALANTA, 1996, 43 (05) : 755 - 759
  • [25] Calibration procedures for a halide Ion-Selective Electrode array
    Baret, E
    Fabry, P
    Massart, DL
    Menardo, C
    Fraysse, M
    ANALUSIS, 1998, 26 (08) : 267 - 277
  • [26] ION-SELECTIVE ELECTRODE FOR QUANTITATIVE DETERMINATION OF BACLOFEN IN PILLS
    Nazarov, V. A.
    Andronchik, K. A.
    Egorov, V. V.
    Belyaev, S. A.
    Yurkshtovich, T. L.
    PHARMACEUTICAL CHEMISTRY JOURNAL, 2011, 45 (06) : 374 - 376
  • [27] Ion-selective electrode for quantitative determination of baclofen in pills
    V. A. Nazarov
    K. A. Andronchik
    V. V. Egorov
    S. A. Belyaev
    T. L. Yurkshtovich
    Pharmaceutical Chemistry Journal, 2011, 45 : 374 - 376
  • [28] POTENTIOMETRIC DETERMINATION OF DIAZEPAM WITH A DIAZEPAM ION-SELECTIVE ELECTRODE
    NIE, LH
    LIU, DZ
    YAO, SZ
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1990, 8 (04) : 379 - 383
  • [29] Semifluorinated Polymers as Ion-selective Electrode Membrane Matrixes
    Carey, Jesse L., III
    Hirao, Akira
    Sugiyama, Kenji
    Buehlmann, Philippe
    ELECTROANALYSIS, 2017, 29 (03) : 739 - 747
  • [30] A selective membrane electrode for salicylate ion based on a bis-salicylaldoxime complex of copper(II) as ionophore
    Wang Fuchang
    Chai Yaqin
    Yuan Ruo
    Gui Guofeng
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2006, 34 (05) : 725 - 728