Design, development and performance evaluation of latent heat storage foot warmers

被引:1
作者
Buddhi, D. [1 ]
Sharma, Atul [2 ]
Sharma, S.
机构
[1] Devi Ahilya Univ, Sch Energy & Environm Studies, Thermal Energy Storage Lab, Khandwa Road Campus, Indore 452017, Madhya Pradesh, India
[2] Kun Shan Univ, Dept Mech Engn, Tainan, Taiwan
关键词
energy storage; thermal cycle; Phase Change Materials; PCM; solar energy; solar foot warmer; latent heat storage;
D O I
10.1504/IJGEI.2007.016254
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In this paper, three PCM based foot warmers of cylindrical and rectangular in shape were designed, developed and fabricated to store solar energy during sunshine hours. The stored energy was utilised to warm the feet in the late evening to replace electric heaters. By trial experiment, it was found out that the surface temperature of the storage units of the foot warmer should be between 37 degrees C-41 degrees C for heating the feet. Therefore, commercial grade lauric acid (Melting Point 42.2 degrees C, Latent Heat of Fusion 181 x 10(3) J/kg) was used as a latent heat storage material. Experiments were conducted during a winter season to study the latent heat storage units and the thermal performance of the rectangular shaped foot warmer was found better than the cylindrical shaped with the same storage capacity. The experimental thermal performance studies of these latent heat storage systems showed that such type of foot warmer can be used for heating purpose of the feet and legs in composite and cold and sunny climates.
引用
收藏
页码:430 / 444
页数:15
相关论文
共 50 条
  • [21] Design, development of a solar chimney with built-in latent heat storage material for natural ventilation
    Sharma, S. D.
    Kotani, H.
    Kaneko, Y.
    Yamanaka, T.
    Sagara, K.
    INTERNATIONAL JOURNAL OF GREEN ENERGY, 2007, 4 (03) : 313 - 324
  • [22] Experimental Study on Thermal Performance of Xylitol in A Latent Heat Storage Combined With Sensible Heat Storage
    Saikrishnan, V.
    Karthikeyan, A.
    Selvaraj, B.
    RENEWABLE ENERGY SOURCES AND TECHNOLOGIES, 2019, 2161
  • [23] Effect of unsteady heat source condition on thermal performance for cascaded latent heat storage packed bed
    Mao, Qianjun
    Zhang, Yufei
    ENERGY, 2023, 284
  • [24] Thermal performance analysis of a new multiple flat-plate latent heat storage heat exchanger
    Wang, Meijie
    Liu, Weijie
    JOURNAL OF ENERGY STORAGE, 2024, 98
  • [25] Thermal performance analysis of novel bionic fins in a concentric three-tube latent heat storage system
    Fang, Zhicheng
    Zhao, Chuntian
    RENEWABLE ENERGY, 2025, 243
  • [26] System design and energy performance of a solar heat pump heating system with dual-tank latent heat storage
    Qu, Shilin
    Ma, Fei
    Ji, Ru
    Wang, Dongxu
    Yang, Lixiang
    ENERGY AND BUILDINGS, 2015, 105 : 294 - 301
  • [27] Thermal performance of triplex-tube latent heat storage exchanger: simultaneous heat storage and hot water supply via condensation heat recovery
    Cao, Xiaoling
    Zhang, Nan
    Yuan, Yanping
    Luo, Xiaolong
    RENEWABLE ENERGY, 2020, 157 : 616 - 625
  • [28] Exergy based performance evaluation of latent heat thermal storage system: A review
    Jegadheeswaran, S.
    Pohekar, S. D.
    Kousksou, T.
    RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2010, 14 (09) : 2580 - 2595
  • [29] Improvement of melting performance in a longitudinal finned latent heat thermal energy storage unit
    Laasri, Imad Ait
    Elmaazouzi, Zakaria
    El Alami, Mustapha
    Outzourhit, Abdelkader
    Bennouna, El Ghali
    ENERGY STORAGE, 2024, 6 (01)
  • [30] Analytical modeling and thermal performance analysis of a flat plate latent heat storage unit
    Ding, Chen
    Niu, Zhiling
    Li, Bingwei
    Hong, Dongpao
    Zhang, Zijun
    Yu, Muchun
    APPLIED THERMAL ENGINEERING, 2020, 179