DEPENDENCE OF ULTRASONIC-ATTENUATION OF LIVER ON PATHOLOGICAL FAT AND FIBROSIS - EXAMINATION WITH EXPERIMENTAL FATTY LIVER AND LIVER FIBROSIS MODELS

被引:31
作者
SUZUKI, K
HAYASHI, N
SASAKI, Y
KONO, M
KASAHARA, A
FUSAMOTO, H
IMAI, Y
KAMADA, T
机构
[1] OSAKA UNIV,SCH MED,DEPT MED 1,1-1-50 FUKUSHIMA,FUKUSHIMA KU,OSAKA 553,JAPAN
[2] SHIMADZU CO LTD,DIV PROC INSTRUMENTAT,RES & DEV ENGN,KYOTO 604,JAPAN
关键词
ATTENUATION; ULTRASOUND; RABBIT LIVER; EXPERIMENTAL FATTY LIVER MODEL; EXPERIMENTAL LIVER FIBROSIS MODEL; FAT CONTENT; COLLAGEN CONTENT; WATER CONTENT;
D O I
10.1016/0301-5629(92)90116-R
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
To clarify the effect of the pathological state of the liver on ultrasonic attenuation, we produced two experimental rabbit models. The influence of fat on ultrasonic attenuation was examined using a fatty liver model without liver fibrosis, and that of fibrosis on attenuation using a liver fibrosis model without fatty infiltration. Ultrasonic data were obtained in vivo directly from the liver, and an acoustic attenuation coefficient slope was obtained by the spectral difference method. Tissue components of the liver, namely the total lipid, hydroxyproline and water contents, were measured precisely by quantitative methods. We revealed that ultrasonic attenuation depends mainly on fatty infiltration of the liver and to a lesser extent on fibrosis, but not on the water content.
引用
收藏
页码:657 / 666
页数:10
相关论文
共 23 条
[1]   INFLUENCE OF PATHOLOGICAL STATE ON THE ACOUSTIC ATTENUATION COEFFICIENT SLOPE OF LIVER [J].
AFSCHRIFT, M ;
CUVELIER, C ;
RINGOIR, S ;
BARBIER, F .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1987, 13 (03) :135-139
[2]   ACOUSTIC PROPERTIES OF NORMAL AND CANCEROUS HUMAN-LIVER .2. DEPENDENCE ON TISSUE STRUCTURE [J].
BAMBER, JC ;
HILL, CR ;
KING, JA .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1981, 7 (02) :135-144
[3]   QUICK AND SPECIFIC ASSAY FOR HYDROXYPROLINE [J].
BLUMENKRANTZ, N ;
ASBOEHAN.G .
ANALYTICAL BIOCHEMISTRY, 1973, 55 (01) :288-291
[4]   Carbon tetrachloride cirrhosis in relation to liver regeneration. [J].
Cameron, GR ;
Karunaratne, WAE .
JOURNAL OF PATHOLOGY AND BACTERIOLOGY, 1936, 42 (01) :1-21
[5]   INVIVO ACOUSTIC ATTENUATION IN LIVER - CORRELATIONS WITH BLOOD-TESTS AND HISTOLOGY [J].
DUERINCKX, A ;
ROSENBERG, K ;
HOEFS, J ;
AUFRICHTIG, D ;
COLEBEUGLET, C ;
KANEL, G ;
LOTTENBERG, S ;
FERRARI, LA .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1988, 14 (05) :405-413
[6]  
FOLCH J, 1957, J BIOL CHEM, V226, P497
[7]   ACCURACY OF ULTRASONOGRAPHY IN DIAGNOSIS OF HEPATOCELLULAR DISEASE [J].
GOSINK, BB ;
LEMON, SK ;
SCHEIBLE, W ;
LEOPOLD, GR .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1979, 133 (01) :19-23
[8]   IMPROVEMENTS IN THE SPECTRAL DIFFERENCE METHOD FOR MEASURING ULTRASONIC-ATTENUATION [J].
INSANA, M ;
ZAGZEBSKI, J ;
MADSEN, E .
ULTRASONIC IMAGING, 1983, 5 (04) :331-345
[9]  
JORGENSEN M, 1974, ACTA PATH MICRO IM A, VA 82, P13
[10]   CLINICAL-APPLICATION OF AN ULTRASOUND ATTENUATION COEFFICIENT ESTIMATION TECHNIQUE FOR LIVER PATHOLOGY CHARACTERIZATION [J].
KUC, R .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1980, 27 (06) :312-319