SYMPATHETIC ACTIVATION DECREASES MEDIUM-SIZED ARTERIAL COMPLIANCE IN HUMANS

被引:189
作者
BOUTOUYRIE, P
LACOLLEY, P
GIRERD, X
BECK, L
SAFAR, M
LAURENT, S
机构
[1] HOP BROUSSAIS, DEPT INTERNAL MED, SERV PHARMACOL, F-75674 PARIS 14, FRANCE
[2] HOP BROUSSAIS, DEPT PHARMACOL, F-75674 PARIS 14, FRANCE
[3] INSERM, U337, PHARMACOL LAB, F-75270 PARIS 06, FRANCE
来源
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY | 1994年 / 267卷 / 04期
关键词
RADIAL ARTERY; ECHO TRACKING SYSTEM; COLD PRESSER TEST; MENTAL STRESS; SYMPATHETIC SYSTEM;
D O I
10.1152/ajpheart.1994.267.4.H1368
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
This study used a precise noninvasive method in normotensive humans to determine the effects of sympathetic activation on arterial compliance. A recently developed, high-resolution echo-tracking system capable of measuring systolic/diastolic variations of arterial diameter was coupled to a Finapres system and used to calculate instantaneous systolic/diastolic pressure-diameter and compliance-pressure curves for a muscular medium-sized artery, the radial artery. Two standardized tests of sympathetic system activation, a cold presser test (2 min) and a mental stress test (2 min of mental arithmetic), were performed at an interval of 8 days in random order in nine healthy volunteers [30 +/- 9 (SD) yr]. Radial arterial parameters were recorded every 30 s for 9 min, which included 2 min of cold presser test or mental stress test. During both tests, radial arterial mean diameter did not change despite the increase in mean arterial pressure (P < 0.001); stroke change in diameter decreased (P < 0.01), whereas pulse pressure increased (P < 0.01). Arterial compliance, calculated for the instantaneous level of mean arterial pressure, decreased significantly (P < 0.01). Compliance (C) calculated at 100 mmHg (C-100) was arbitrarily chosen as a reference point for comparing compliance among the different periods of the test. C-100 decreased significantly (P < 0.05) during both tests (from 2.93 +/- 1.27 to 2.04 +/- 0.94 and from 3.29 +/- 1.73 to 2.63 +/- 1.55 mm(2).mmHg(-1).10(-3) during mental stress and the cold presser test, respectively). These results indicate that sympathetic activation is able to decrease radial arterial compliance in healthy subjects. The reduction in arterial compliance probably resulted from complex interactions between changes in distending blood pressure and changes in radial arterial smooth muscle tone.
引用
收藏
页码:H1368 / H1376
页数:9
相关论文
共 33 条