INVITRO HISTAMINE-RELEASE INDUCED BY MAGNETIC-RESONANCE-IMAGING AND IODINATED CONTRAST-MEDIA

被引:24
|
作者
BAXTER, AB
LAZARUS, SC
BRASCH, RC
机构
[1] UNIV CALIF SAN FRANCISCO,DEPT MED,SAN FRANCISCO,CA 94143
[2] UNIV CALIF SAN FRANCISCO,CARDIOVASC RES INST,SAN FRANCISCO,CA 94143
关键词
ALLERGY; HISTAMINE; CONTRAST MEDIA; MAST CELL; MAGNETIC RESONANCE IMAGING; CONTRAST ENHANCEMENT; GADOLINIUM;
D O I
10.1097/00004424-199304000-00009
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
RATIONALE AND OBJECTIVES. To investigate the mechanism of anaphylactoid reactions to contrast media, in vitro histamine release induced by magnetic resonance imaging, and iodinated contrast agents was examined in a dog mastocytoma cell line. METHODS. Two gadolinium (Gd)-based magnetic resonance contrast agents, Gd diethylenetriamine pentaacetic acid (Gd-DTPA), dimeglumine, and Gd-bismorpholide, and two iodinated contrast agents, diatrizoate meglumine and iohexol, were incubated with histamine-containing canine mastocytoma cells. Release of histamine into the supernatant was determined at various contrast-medium concentrations after incubation at 37-degrees-C for 30 minutes. RESULTS. Iodinated and Gd-based contrast agents caused release of histamine from mastocytoma cells at similar concentrations (50-150 mM). Mannitol, an osmotic stimulus, caused release of histamine only at concentrations greater than 1,000 mM. CONCLUSIONS. Histamine release from canine mastocytoma cells does not appear to be solely due to osmotic effects, but results from direct stimulation by contrast media. For all agents examined, the concentration at which in vitro histamine release occurs far exceeds the serum contrast media concentration expected in routine clinical application. Direct release of histamine from mast cells does not completely explain the pathogenesis of idiosyncratic anaphylactoid responses to contrast media.
引用
收藏
页码:308 / 312
页数:5
相关论文
共 50 条
  • [21] CONTRAST-MEDIA FOR NUCLEAR MAGNETIC-RESONANCE IMAGING
    BRASCH, RC
    WESBEY, GE
    DOEMENY, J
    MCNAMARA, M
    EHMAN, R
    INVESTIGATIVE RADIOLOGY, 1984, 19 (04) : S148 - S148
  • [22] MAGNETIC-RESONANCE CONTRAST-MEDIA FOR MYOCARDIAL IMAGING
    HIGGINS, CB
    SAEED, M
    WENDLAND, MF
    INVESTIGATIVE RADIOLOGY, 1990, 25 : S74 - S74
  • [23] EVALUATION OF HISTAMINE-RELEASE FOLLOWING INTRAVENOUS-INJECTION OF IONIC AND NONIONIC CONTRAST-MEDIA
    PINET, A
    COROT, C
    BIOT, N
    ELOY, R
    INVESTIGATIVE RADIOLOGY, 1988, 23 : S174 - S177
  • [24] NEPHROPATHY INDUCED BY IODINATED CONTRAST-MEDIA AND DIABETES
    PERMAL, S
    VERNY, C
    BELLIN, MF
    GRELLET, J
    GRIMALDI, A
    JOURNAL D UROLOGIE, 1992, 98 (01) : 46 - 49
  • [25] QUANTIFICATION OF CAPILLARY-PERMEABILITY TO MACROMOLECULAR MAGNETIC-RESONANCE-IMAGING CONTRAST-MEDIA IN EXPERIMENTAL MAMMARY ADENOCARCINOMAS
    BRASCH, RC
    SHAMES, DM
    COHEN, FM
    KUWATSURU, R
    NEUDER, M
    MANN, JS
    VEXLER, V
    MUHLER, A
    ROSENAU, W
    INVESTIGATIVE RADIOLOGY, 1994, 29 : S8 - S11
  • [26] DETERMINATION OF LYMPHOKINE INDUCED HISTAMINE-RELEASE INVITRO
    DUMONDE, DC
    JASANI, MK
    SJOGREN, HK
    WOLSTENCROFT, RA
    BRITISH JOURNAL OF PHARMACOLOGY, 1980, 68 (01) : P124 - P124
  • [27] INVITRO EFFECTS OF IODINATED ARTHROGRAPHIC CONTRAST-MEDIA ON BACTERIAL-GROWTH
    MELSON, GL
    MCDANIEL, RC
    SOUTHERN, PM
    STAPLE, TW
    RADIOLOGY, 1974, 112 (03) : 593 - 595
  • [28] MEASUREMENT OF N-TAU-METHYLHISTAMINE CONCENTRATIONS IN URINE AS A PARAMETER FOR HISTAMINE-RELEASE BY RADIOGRAPHIC CONTRAST-MEDIA
    KEYZER, JJ
    UDDING, H
    DEVRIES, K
    DIAGNOSTIC IMAGING IN CLINICAL MEDICINE, 1984, 53 (02) : 67 - 72
  • [29] HISTAMINE-RELEASE AND PSEUDOALLERGIC REACTIONS INDUCED BY RADIOGRAPHIC CONTRAST-MEDIA - COMPARISON OF ANGIOGRAPHIN, HEXABRIX AND TELEBRIX USING AN INVIVO CANINE MODEL
    ENNIS, M
    LORENZ, W
    SCHMAL, A
    DOMBROWSKI, H
    AGENTS AND ACTIONS, 1990, 30 (1-2): : 81 - 84
  • [30] INVITRO EVALUATION OF A MECHANICAL INJECTOR FOR INFUSION OF MAGNETIC-RESONANCE CONTRAST-MEDIA
    SAINI, S
    FRETZ, CJ
    FISEL, CR
    ROSEN, BR
    FERRUCCI, JT
    INVESTIGATIVE RADIOLOGY, 1991, 26 (08) : 748 - 751