Analysis of in-service aged stator bars

被引:17
作者
Morin, R [1 ]
Novak, JP [1 ]
Bartnikas, R [1 ]
Ross, R [1 ]
机构
[1] INST RECH HYDRO QUEBEC,MONTREAL,PQ,CANADA
关键词
D O I
10.1109/60.475834
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Stator bars subjected to operating stresses for 7 and 22 year periods were retrieved from a hydro-generator to undergo short term electrical diagnostic tests in order to determine whether any significant aging of the insulation had taken place. The ac breakdown voltage (U-bk), partial discharge inception voltage (PDIV), the maximum charge (Delta Q(m)) and total apparent charge GRAPHICS transfer of the partial discharges, tan delta and tan delta tip-up comprised the measured quantities statistically evaluated in the diagnostic test procedure. The ac breakdown voltage, PDIV and Delta Q(m) were found to exhibit a systematic trend with in-service time, thereby suggesting the occurrence of aging effects. That is, both the ac breakdown voltage and the PDIV were characterized by a decrease with time in-service, whilst the Delta Q(m) value exhibited an increase. However, no definite behavior was evinced by the GRAPHICS tan delta and tan delta tip-up values. me significance of the diagnostic test results is discussed in terms of Weibull statistics and the partial discharge behavior with time.
引用
收藏
页码:645 / 654
页数:10
相关论文
共 30 条
[1]   AC BREAKDOWN CHARACTERISTICS OF IN-SERVICE AGED XLPE DISTRIBUTION CABLES [J].
BARTNIKAS, R ;
PELISSOU, S ;
STONGE, H .
IEEE TRANSACTIONS ON POWER DELIVERY, 1988, 3 (02) :454-462
[2]   CORONA PULSE PROBABILITY DENSITY-FUNCTION MEASUREMENTS ON PRIMARY DISTRIBUTION POWER-CABLES [J].
BARTNIKAS, R .
IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1975, PA94 (03) :716-723
[3]   ON THE CHARACTER OF DIFFERENT FORMS OF PARTIAL DISCHARGE AND THEIR RELATED TERMINOLOGIES [J].
BARTNIKAS, R ;
NOVAK, JP .
IEEE TRANSACTIONS ON ELECTRICAL INSULATION, 1993, 28 (06) :956-968
[4]  
BARTNIKAS R, 1966, P CIGRE PARIS, V2, P1
[5]  
CACCIARI M, 1993, OCT IEEE C EL INS DI, P414
[6]  
CAMERON AWW, 1959, AIEE T POWER APPARAT, V78, P178
[7]   PD ANALYSIS OF ROTATING AC MACHINES [J].
CONTIN, A ;
RABACH, G .
IEEE TRANSACTIONS ON ELECTRICAL INSULATION, 1993, 28 (06) :1033-1042
[8]   MULTIPLE STRESS AGING OF SOLID-DIELECTRIC EXTRUDED DRY-CURED INSULATION SYSTEMS FOR POWER TRANSMISSION CABLES [J].
DENSLEY, RJ ;
BARTNIKAS, R ;
BERNSTEIN, B .
IEEE TRANSACTIONS ON POWER DELIVERY, 1994, 9 (01) :559-571
[9]   ASSESSMENT OF INSULATION CONDITION IN ROTATING MACHINE STATORS [J].
GUPTA, BK ;
CULBERT, IM .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 1992, 7 (03) :500-508
[10]  
GUPTA BK, 1986, 1986 IEEE INT S EL I, P285