GAS-CHROMATOGRAPHIC WATER ANALYSIS BY DIRECT-INJECTION OF LARGE-SAMPLE VOLUMES IN AN ADSORBENT-PACKED PTV INJECTOR

被引:43
作者
MULLER, S [1 ]
EFER, J [1 ]
ENGEWALD, W [1 ]
机构
[1] UNIV LEIPZIG,INST ANALYT CHEM,D-04103 LEIPZIG,GERMANY
关键词
GAS CHROMATOGRAPHY; PTV INJECTION SYSTEM; AQUEOUS SAMPLES; PESTICIDES; BREAKTHROUGH VOLUMES;
D O I
10.1007/BF02269623
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A GC method is described for the determination of pollutants in aqueous samples by direct enrichment out of large sample volumes in a PTV injector. The vaporized water is eliminated through the split vent and the analytes are concentrated on an adsorbent inside the insert of the PTV. For the selection of suitable adsorbents, breakthrough volumes of selected pesticides and nitroaromatics on Tenax TA, Tenax GR, Chemipack C18 and graphitized carbon blacks have been determined by experiment. The determination of the breakthrough volumes was carried out directly in the PTV insert. Tenax TA proved to be the best sorbent with regard to the breakthrough volumes and its inertness to the analytes to be determined. As the result of the investigations, 500 mu l of aqueous standard solutions of pesticides and nitroaromatics (concn. = 0.02 ... 2 mu g/l) were analyzed with an average relative standard deviation of 10 %. The procedure was successfully applied for the analysis of real samples.
引用
收藏
页码:694 / 700
页数:7
相关论文
共 11 条
[1]  
BRAUNSTEIN L, 1990, VOM WASSER, V75, P1
[2]   INDIRECT GC DETERMINATION OF ETHEPHON IN DRINKING-WATER BY A COMBINATION OF REACTIVE HEADSPACE SAMPLING WITH ADSORPTIVE ENRICHMENT THERMAL-DESORPTION [J].
EFER, J ;
MULLER, S ;
ENGEWALD, W ;
KNOBLOCH, T ;
LEVSEN, K .
CHROMATOGRAPHIA, 1993, 37 (7-8) :361-364
[3]   ADSORBENTS FOR THE ENRICHMENT OF ORGANIC ATMOSPHERIC TRACE COMPOUNDS - EXPERIMENTAL-DETERMINATION OF SPECIFIC RETENTION AND BREAKTHROUGH VOLUMES [J].
FIGGE, K ;
RABEL, W ;
WIECK, A .
FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1987, 327 (3-4) :261-278
[4]  
GROB K, 1993, HRC-J HIGH RES CHROM, V16, P224
[5]  
KNOBLOCH T, 1993, THESIS U LEIPZIG
[6]  
MOL HGJ, 1993, HRC-J HIGH RES CHROM, V16, P459, DOI 10.1002/jhrc.1240160803
[7]  
MULLER S, 1993, VOM WASSER, V81, P135
[8]   TENAX-GC CARTRIDGE FOR INTERFACING CAPILLARY COLUMN GAS-CHROMATOGRAPHY WITH ADSORPTION THERMAL-DESORPTION FOR DETERMINATION OF TRACE ORGANICS [J].
PANKOW, JF ;
ISABELLE, LM ;
KRISTENSEN, TJ .
ANALYTICAL CHEMISTRY, 1982, 54 (11) :1815-1819
[9]   SELECTIVE AND NON-SELECTIVE SAMPLING FROM PRECOLUMN SEPARATIONS - WITH EMPHASIS ON THE SAMPLING OF AQUEOUS-SOLUTIONS [J].
SCHOMBURG, G ;
BASTIAN, E ;
BEHLAU, H ;
HUSMANN, H ;
WEEKE, F ;
OREANS, M ;
MULLER, F .
JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY & CHROMATOGRAPHY COMMUNICATIONS, 1984, 7 (01) :4-12
[10]   SOLVENT ELIMINATION RATE IN TEMPERATURE-PROGRAMMED INJECTIONS OF LARGE SAMPLE VOLUMES IN CAPILLARY GAS-CHROMATOGRAPHY [J].
STANIEWSKI, J ;
RIJKS, JA .
JOURNAL OF CHROMATOGRAPHY, 1992, 623 (01) :105-113