FLOW PATTERN-ANALYSIS IN THE ABDOMINAL-AORTA WITH VELOCITY-ENCODED CINE MR-IMAGING

被引:17
|
作者
MOSTBECK, GH [1 ]
DULCE, MC [1 ]
CAPUTO, GR [1 ]
PROCTOR, E [1 ]
HIGGINS, CB [1 ]
机构
[1] UNIV CALIF SAN FRANCISCO,DEPT RADIOL,BOX 0628,RM L308,505 PARNASSUS AVE,SAN FRANCISCO,CA 94143
来源
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING | 1993年 / 3卷 / 04期
关键词
AORTA; ARTERIOSCLEROSIS; FLOW DYNAMICS; BLOOD; CINE STUDIES; VASCULAR STUDIES; VELOCITY STUDIES;
D O I
10.1002/jmri.1880030411
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The sites of deposition of atherosclerotic plaque on the aortic wall are considered to be influenced by secondary and retrograde flow patterns that cause regions of altered shear stress. To detect secondary flow patterns and areas of retrograde flow in the abdominal aorta, velocity-encoded cine (VEC) magnetic resonance (MR) imaging was performed at five different levels of the abdominal aorta in nine healthy volunteers. Net retrograde flow (expressed as a percentage of antegrade flow) increased from proximal to distal levels and was maximal (13.8% +/- 11.8) just distal to the origin of the renal arteries. An increase in the duration of retrograde flow over the cardiac cycle was observed from proximal to distal levels. Whereas retrograde flow was present at end systole and early diastole in each volunteer at every level, the duration and amount of retrograde flow during diastole showed high interindividual variation. Such differences suggest the possibility of variable vascular geometric risk factors in the population for the development of atherosclerotic plaque. The location of retrograde flow in the abdominal aorta demonstrated in vivo with VEC MR imaging was close to that obtained with in vitro flow visualization studies in models of the abdominal aorta.
引用
收藏
页码:617 / 623
页数:7
相关论文
共 18 条
  • [1] SEVERITY OF AORTIC REGURGITATION - INTERSTUDY REPRODUCIBILITY OF MEASUREMENTS WITH VELOCITY-ENCODED CINE MR-IMAGING
    DULCE, MC
    MOSTBECK, GH
    OSULLIVAN, M
    CHEITLIN, M
    CAPUTO, GR
    HIGGINS, CB
    RADIOLOGY, 1992, 185 (01) : 235 - 240
  • [2] Quantification of flow dynamics in congenital heart disease: Applications of velocity-encoded cine MR imaging
    Varaprasathan, GA
    Araoz, PA
    Higgins, CB
    Reddy, GP
    RADIOGRAPHICS, 2002, 22 (04) : 895 - 905
  • [3] PULMONARY-HYPERTENSION - PULMONARY FLOW QUANTIFICATION AND FLOW PROFILE ANALYSIS WITH VELOCITY-ENCODED CINE MR IMAGING
    KONDO, C
    CAPUTO, GR
    MASUI, T
    FOSTER, E
    OSULLIVAN, M
    STULBARG, MS
    GOLDEN, J
    CATTERJEE, K
    HIGGINS, CB
    RADIOLOGY, 1992, 183 (03) : 751 - 758
  • [4] Coronary sinus flow measurement by means of velocity-encoded cine MR imaging:: Validation by using flow probes in dogs
    Lund, GK
    Wendland, MF
    Shimakawa, A
    Arheden, H
    Ståhlberg, F
    Higgins, CB
    Saeed, M
    RADIOLOGY, 2000, 217 (02) : 487 - 493
  • [5] TRACKING THE MOTION OF SKELETAL-MUSCLE WITH VELOCITY-ENCODED MR-IMAGING
    DRACE, JE
    PELC, NJ
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 1994, 4 (06) : 773 - 778
  • [6] Coronary flow reserve: Noninvasive measurement in humans with breath-hold velocity-encoded cine MR imaging
    Sakuma, H
    Blake, LM
    Amidon, TM
    OSullivan, M
    Szolar, DH
    Furber, AP
    Bernstein, MA
    Foo, TKF
    Higgins, CB
    RADIOLOGY, 1996, 198 (03) : 745 - 750
  • [7] RIGHT AND LEFT LUNG PERFUSION - INVITRO AND INVIVO VALIDATION WITH OBLIQUE-ANGLE, VELOCITY-ENCODED CINE MR IMAGING
    CAPUTO, GR
    KONDO, C
    MASUI, T
    GERACI, SJ
    FOSTER, E
    OSULLIVAN, MM
    HIGGINS, CB
    RADIOLOGY, 1991, 180 (03) : 693 - 698
  • [8] VELOCITY AND FLOW QUANTITATION IN THE SUPERIOR SAGITTAL SINUS WITH UNGATED AND CINE (GATED) PHASE-CONTRAST MR-IMAGING
    JORDAN, JE
    PELC, NJ
    ENZMANN, DR
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1994, 4 (01): : 25 - 28
  • [9] COMPARISON OF VELOCITY-ENCODED MR IMAGING AND FLUID DYNAMIC MODELING OF STEADY AND DISTURBED FLOW
    SUN, Y
    HEARSHEN, DO
    RANKIN, GW
    HAGGAR, AM
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1992, 2 (04): : 443 - 452
  • [10] Chronic heart failure: Global left ventricular perfusion and coronary flow reserve with velocity-encoded cine MR imaging: Initial results
    Lund, GK
    Watzinger, N
    Saeed, M
    Reddy, GP
    Yang, M
    Araoz, PA
    Curatola, D
    Bedigian, M
    Higgins, CB
    RADIOLOGY, 2003, 227 (01) : 209 - 215