SUBSURFACE STORAGE OF COMMERCIAL SPENT NUCLEAR-FUEL

被引:2
作者
RICHARDS, LM [1 ]
SZULINSKI, MJ [1 ]
机构
[1] ARCO CHEM,PHILADELPHIA,PA 19101
关键词
SPENT FUEL STORAGE;
D O I
10.13182/NT79-A16307
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The Atlantic Richfield Company has developed the concept of storing spent fuel in dry caissons. Cooling is passive; safety and safeguard features appear promising. The capacity of a caisson to dissipate heat depends on site-specific soil characteristics and on the diameter of the caisson. It is estimated that similar 2 kW can be dissipated in the length of one fuel element. Fuel elements can be stacked with little effect on temperature. A spacing of similar 7. 5 m (25 ft) between caissons appears reasonable. Business planning indicates a cost of similar . 02 mill/kWh for a 15-yr storage period.
引用
收藏
页码:155 / 164
页数:10
相关论文
共 2 条
  • [1] COX RL, 1973, ORNLTM3373
  • [2] EMERY AF, 1976, COMMUNICATION