OUTFLOW RECONSTRUCTION OF TETRALOGY OF FALLOT USING A GORE-TEX VALVE

被引:52
作者
YAMAGISHI, M [1 ]
KUROSAWA, H [1 ]
机构
[1] JIKEI UNIV,SCH MED,DEPT CARDIOVASC SURG,MINATO KU,TOKYO 105,JAPAN
关键词
D O I
10.1016/0003-4975(93)90700-R
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The right ventricular outflow tract was reconstructed in patients with tetralogy of Fallot using a wide transannular patch bearing a large unicuspid or bicuspid valve. The shape of the valve was designed to limit the degree of pulmonary regurgitation. The characteristics of the valve and the water-repellent nature of the polytetrafluoroethylene sheet make calcification and pseudointimal formation less common than with traditional bioprosthetic valves.
引用
收藏
页码:1414 / 1416
页数:3
相关论文
共 6 条
[1]  
CARVALHO JS, 1992, BRIT HEART J, V67, P470
[2]  
ILBAWI MN, 1987, J THORAC CARDIOV SUR, V93, P36
[3]   CONOTRUNCAL REPAIR OF TETRALOGY OF FALLOT [J].
KUROSAWA, H ;
IMAI, Y ;
NAKAZAWA, M ;
MOMMA, K ;
TAKAO, A .
ANNALS OF THORACIC SURGERY, 1988, 45 (06) :661-666
[4]  
MCGRATH LB, 1988, J THORAC CARDIOV SUR, V96, P947
[5]  
REDINGTON AN, 1988, BRIT HEART J, V60, P57
[6]  
ZAHKA KG, 1988, CIRCULATION, V78, P14