THE RELIABILITY OF FABER TEST HIP RANGE OF MOTION MEASUREMENTS

被引:1
作者
Bagwell, Jennifer J. [1 ]
Bauer, Lauren [1 ]
Gradoz, Marissa [1 ]
Grindstaff, Terry L. [1 ]
机构
[1] Creighton Univ, Dept Phys Therapy, 2500 Calif Plaza, Omaha, NE 68114 USA
来源
INTERNATIONAL JOURNAL OF SPORTS PHYSICAL THERAPY | 2016年 / 11卷 / 07期
关键词
FABER; femoroacetabular impingement; hip; range of motion; reliability;
D O I
暂无
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
Background: The Flexion ABduction External Rotation (FABER) test is typically used as a provocation special test, but has also been used as a measurement of combined hip range of motion (ROM). It is thought that limited ROM with this measurement may be indicative of hip pathology. To date, normative data, reliability, and minimal detectable change (MDC) of such measurements have not been established. Purpose: To determine normative FABER height, assess inter- and intra-rater reliability and MDC for FABER, and compare traditional FABER measurements to methods which account for differences in thigh length. Study Design: Descriptive laboratory reliability study Methods: Nineteen healthy participants without low back, hip, or knee pain in the preceding three months were recruited. Measurements were performed during two sessions (three to seven days between sessions) by three clinicians. FABER height and thigh length measurements were performed. Thigh length normalized FABER range of motion (ROM) and side-to-side FABER ROM symmetry were calculated. One tester also measured FABER with a digital inclinometer. Inter- and intra-rater reliability were calculated using interclass correlation coefficients (ICC) and mean MDC values were calculated. Results: Mean values for FABER height and normalized FABER ROM were 12.4 +/- 2.8 cm and 0.30 +/- 0.07, respectively. Inter-rater reliability for FABER and normalized FABER were good (ICC 0.67-0.68) and between session intra-rater reliability were good to excellent (ICC 0.76-0.86). Mean FABER and normalized FABER ROM MDC were 3.7 cm and 0.04, respectively. Mean FABER ROM symmetry was 2.0 +/- 0.9 cm with poor inter-rater reliability (ICC 0.20), poor to good intra-rater reliability (ICC 0.38-0.66), and mean MDC of 4.0 cm. FABER measured with a ruler, normalized FABER ROM, and inclinometry all resulted in excellent intra-rater reliability, with the highest ICC being demonstrated for inclinometry (ICC 0.86, 0.86, and 0.91). Conclusions: Overall, FABER measurements were reliable, whether normalized to thigh length or not. Furthermore, use of inclinometry may increase reliability. Reliability was poor to good when assessing symmetry between limbs.
引用
收藏
页码:1101 / 1105
页数:5
相关论文
共 15 条
  • [1] Cicchetti D., 1994, PSYCHOL ASSESS, V6, P284, DOI [10.1037/1040-3590.6.4.284, DOI 10.1037/1040-3590.6.4.284]
  • [2] In-vivo hip arthrokinematics during supine clinical exams: Application to the study of femoroacetabular impingement
    Kapron, Ashley L.
    Aoki, Stephen K.
    Peters, Christopher L.
    Anderson, Andrew E.
    [J]. JOURNAL OF BIOMECHANICS, 2015, 48 (11) : 2879 - 2886
  • [3] Accuracy and Feasibility of Dual Fluoroscopy and Model-Based Tracking to Quantify in Vivo Hip Kinematics During Clinical Exams
    Kapron, Ashley L.
    Aoki, Stephen K.
    Peters, Christopher L.
    Maas, Steve A.
    Bey, Michael J.
    Zauel, Roger
    Anderson, Andrew E.
    [J]. JOURNAL OF APPLIED BIOMECHANICS, 2014, 30 (03) : 461 - 470
  • [4] Magee DJ, 2014, ORTHOPEDIC PHYS ASSE
  • [5] The interrater reliability of 4 clinical tests used to assess individuals with musculoskeletal hip pain
    Martin, RobRoy L.
    Sekiya, Jon K.
    [J]. JOURNAL OF ORTHOPAEDIC & SPORTS PHYSICAL THERAPY, 2008, 38 (02) : 71 - 77
  • [6] Acetabular labral tears of the hip: Examination and diagnostic challenges
    Martin, RobRoy L.
    Enseki, Keelan R.
    Draovitch, Peter
    Trapuzzano, Talia
    Philippon, Marc J.
    [J]. JOURNAL OF ORTHOPAEDIC & SPORTS PHYSICAL THERAPY, 2006, 36 (07) : 503 - 515
  • [7] The Diagnostic Validity of Hip Provocation Maneuvers to Detect Intra-Articular Hip Pathology
    Maslowski, Erin
    Sullivan, William
    Harwood, Jeri Forster
    Gonzalez, Peter
    Kaufman, Marla
    Vidal, Armando
    Akuthota, Venu
    [J]. PM&R, 2010, 2 (03) : 174 - 181
  • [8] Hip joint pathology: Clinical presentation and correlation between magnetic resonance arthrography, ultrasound, and arthroscopic findings in 25 consecutive cases
    Mitchell, B
    McCrory, P
    Brukner, P
    O'Donnell, J
    Colson, E
    Howells, R
    [J]. CLINICAL JOURNAL OF SPORT MEDICINE, 2003, 13 (03): : 152 - 156
  • [9] Clinical presentation of femoroacetabular impingement
    Philippon, Marc J.
    Maxwell, R. Brian
    Johnston, Todd L.
    Schenker, Mara
    Briggs, Karen K.
    [J]. KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2007, 15 (08) : 1041 - 1047
  • [10] Hip Arthroscopy and Femoroacetabular Impingement in the Pediatric Patient
    Philippon, Marc J.
    Patterson, Diana C.
    Briggs, Karen K.
    [J]. JOURNAL OF PEDIATRIC ORTHOPAEDICS, 2013, 33 : S126 - S130