BEHAVIOR OF PERFOBOND RIB SHEAR CONNECTORS IN COMPOSITE BEAMS - FULL-SIZE TESTS

被引:54
|
作者
OGUEJIOFOR, EC
HOSAIN, MU
机构
关键词
COMPOSITE BEAM; SHEAR CONNECTOR; PERFOBOND RIB CONNECTOR; HEADED STUD;
D O I
10.1139/l92-028
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper presents the results of six full-size composite beam specimens tested as part of an ongoing research program at the University of Saskatchewan to determine the feasibility of using a new type of shear connector called perfobond rib in composite floor systems. This connector is a flat steel plate with a number of holes punched through. In half of the test specimens, headed stud connectors were used, while in the other half, perfobond rib connectors were used. The results obtained indicate that the perfobond rib connector is a viable alternative to the headed studs. Specimens with four perfobond rib shear connectors performed as well as those with 24 headed studs. The experimentally determined ultimate flexural capacity of the test specimens agreed reasonably well with the predicted values.
引用
收藏
页码:224 / 235
页数:12
相关论文
共 50 条
  • [1] TESTS OF FULL-SIZE COMPOSITE BEAMS WITH PERFOBOND RIB CONNECTORS
    OGUEJIOFOR, EC
    HOSAIN, MU
    CANADIAN JOURNAL OF CIVIL ENGINEERING, 1995, 22 (01) : 80 - 92
  • [2] BEHAVIOR OF PERFOBOND RIB SHEAR CONNECTORS - PUSH-OUT TESTS
    VELDANDA, MR
    HOSAIN, MU
    CANADIAN JOURNAL OF CIVIL ENGINEERING, 1992, 19 (01) : 1 - 10
  • [3] BEHAVIOR OF HEADED STUDS IN COMPOSITE BEAMS - FULL-SIZE TESTS
    JAYAS, BS
    HOSAIN, MU
    CANADIAN JOURNAL OF CIVIL ENGINEERING, 1989, 16 (05) : 712 - 724
  • [4] Shear Behavior of Perfobond Rib Shear Connectors for Pre-fabricated Composite Bridges
    装配式组合梁桥开孔钢板连接件抗剪性能
    2018, Chang'an University (31):
  • [5] Behavior of composite girder with Y-type perfobond rib shear connectors
    Kim, Sang-Hyo
    Choi, Jaegu
    Park, Se-Jun
    Ahn, Jin-Hee
    Jung, Chi-Young
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2014, 103 : 275 - 289
  • [6] Flexural behavior of steel-UHPC composite slabs with perfobond rib shear connectors
    Xiao, Jing-Lin
    Zhou, Min
    Nie, Jian-Guo
    Yang, Teng-Yu
    Fan, Jian-Sheng
    ENGINEERING STRUCTURES, 2021, 245
  • [7] Bearing Capacity of Perfobond Rib Shear Connectors in Composite Girder Bridges
    Su, Qingtian
    Yang, Guotao
    Bradford, Mark A.
    JOURNAL OF BRIDGE ENGINEERING, 2016, 21 (04)
  • [8] A PARAMETRIC STUDY OF PERFOBOND RIB SHEAR CONNECTORS
    OGUEJIOFOR, EC
    HOSAIN, MU
    CANADIAN JOURNAL OF CIVIL ENGINEERING, 1994, 21 (04) : 614 - 625
  • [9] Feasibility study on triangular perfobond rib shear connectors in composite slab
    Ramasamy, Vetturayasudharsanan
    Govindan, Balaji
    MATERIALS TODAY-PROCEEDINGS, 2020, 21 : 133 - 136
  • [10] Shear strength study of perfobond rib connectors
    Department of Bridge Engineering, Tongji University, Shanghai 200092, China
    Harbin Gongye Daxue Xuebao, 2007, SUPPL. 2 (280-282):